Search results for "anterior chamber"

showing 10 items of 43 documents

Device interchangeability on anterior chamber depth and white-to-white measurements: a thorough literature review

2016

We have reviewed a set of recently published studies that compared the anterior chamber depth (ACD) and/or white-to-white (WTW) distance obtained by means of different measuring devices. Since some of those studies reached contradictory conclusions regarding device interchangeability, this review was carried out in attempting to clarify which clinical devices can or cannot be considered as interchangeable in clinical practice to measure ACD and/or WTW distance, among these devices: A-scan, ultrasound biomicroscopy, Orbscan and Orbscan II (Bausch&Lomb Surgical Inc., San Dimas, California, USA), Pentacam and Pentacam HR (Oculus, Wetzlar, Germany), Galilei (Ziemer, Switzerland), Visante optica…

White to whitemedicine.medical_specialtybusiness.industryReviewClinical Practice03 medical and health sciencesOphthalmologyAlcon LaboratoriesAnterior chamber eye0302 clinical medicineOphthalmology030221 ophthalmology & optometryMedicineOptometryOrbscan iiPentacam hrbusiness030217 neurology & neurosurgeryInternational Journal of Ophthalmology
researchProduct

Acu priekšējās kameras stāvoklis pacientiem pirms un pēc intraokulārās lēcas implantācijas

2016

Ievads: Priekšējā kamera ir ļoti svarīga acs struktūra, kas ir pildīta ar intraokulāro šķidrumu (IOŠ), kas cirkulē caur priekšējo kameras kaktu uz drenāžas kanāliem. Šīm struktūrām ir nopietna loma glaukomas attīstības patoģenēzē. Nepieciešams noskaidrot kā viena no visbiežākajām ķirurģiskajām manipulācijām (kataraktas operācija) ietekmē priekšējās kameras parametrus. Pētījuma mērķis bija izvērtēt izmaiņas acs priekšējās kameras parametros pēc fakoemulsifikācijas un inrtaokulārās lēcas (IOL) implantācijas, izmantojot Pentacam (Oculus, Wetzlar, Germany). Metodes un materiāli: Tika veikts prospektīvs pētījums. Pētījumā piedalījās 18 pacienti (20 acis), kuriem tika izvērtēts un salīdzināts acs…

anterior chamberslēgta kakta glaukomacataract surgerykataraktas operācijaacs priekšējā kameraMedicīna
researchProduct

Endothelial cells loss to the hyperopic pacients during phacoemulsification

2018

Introduction The phacoemulsification cataract surgery is the most frequently performed surgery and it generally improves vision in over 90% of the patients. Hyperopic patients are a challenge during phacoemulsification especially because of their short eyeball and shallow anterior chamber. A shallow anterior chamber is associated with overall reduction of the safe zone, which may lead to difficulty in creating the corneal incisions, harder capsulorhexis performing, or endothelial complications. Purpose The aim of the study was to present the endothelial cells loss after the phacoemulsification procedure in the hyperopic patients. Material and methods A number of 1775 patients operated in th…

hyperopiaspecular microscopyCorneal endotheliummedicine.medical_specialtygenetic structuresEndotheliummedicine.medical_treatmentHypermetropiaEmmetropiaCataractLens Implantation IntraocularCorneaOphthalmologymedicineHumansCapsulorhexisPhacoemulsificationbusiness.industryEndothelium Cornealshallow anterior chamberEndothelial CellsGeneral MedicinePhacoemulsificationCataract surgeryeye diseasesmedicine.anatomical_structureGeneral ArticlesbusinessRomanian Journal of Ophthalmology
researchProduct

Agreement between 2 swept-source OCT biometers and a Scheimpflug partial coherence interferometer

2020

PURPOSE To evaluate the agreement between different parameters obtained with 2 swept-source optical coherence tomography (SS-OCT)-based biometers and 1 Scheimpflug camera with partial coherence interferometry (PCI). SETTING Single center, Oftalvist, Alicante, Spain. DESIGN Prospective case series. METHODS Biometry was performed in 49 eyes using 3 optical biometers: ANTERION SS-OCT, IOLMaster 700 SS-OCT, and Pentacam AXL PCI. Keratometry (K), J0 and J45 vectors, anterior chamber depth (ACD), central corneal thickness (CCT), white-to-white (WTW), lens thickness (LT), and axial length (AL) were measured with each device. Bland-Altman analysis was applied. RESULTS This study comprises 49 eyes o…

medicine.medical_specialtyBiometryAnterior ChamberScheimpflug principlelaw.inventionCornea03 medical and health sciences0302 clinical medicineOptical coherence tomographyLens thicknesslawOphthalmologymedicineHumansProspective StudiesMathematicsKeratometermedicine.diagnostic_testLimits of agreementSignificant differenceReproducibility of ResultsSensory SystemsAxial Length EyeOphthalmologyInterferometryInterferometrySpain030221 ophthalmology & optometrySurgeryTomography Optical Coherence030217 neurology & neurosurgeryPartial coherenceJournal of Cataract and Refractive Surgery
researchProduct

Determining postoperative anterior chamber depth

2003

Abstract Purpose: To compare measured and calculated postoperative anterior chamber depths (ACDs). Setting: Department of Ophthalmology and Institute of Medical Physics, University of Vienna, Vienna, Austria, and Department of Ophthalmology, University of Mainz, Mainz, Germany. Methods: The postoperative ACD was measured in 189 pseudophakic eyes using a laboratory prototype of partial coherence interferometry (PCI). In 6 intraocular lens (IOL) groups, the mean ACD was calculated by ray tracing based on the best-known A-constants of the SRK formulas. In addition, for each IOL type, each measured ACD was compared with a value calculated using the individual spherical equivalent of the postope…

medicine.medical_specialtyBiometryLightPseudophakiaAnterior Chambermedicine.medical_treatmentIntraocular lensSpherical equivalentLens Implantation IntraocularPower calculationsOphthalmologymedicineHumansPostoperative PeriodLenses Intraocularbusiness.industryModels TheoreticalCataract surgeryRefractionSensory SystemsOphthalmologyInterferometryPartial coherence interferometryConventional PCISurgerybusinessJournal of Cataract and Refractive Surgery
researchProduct

Osmolality of various viscoelastic substances: comparative study.

2000

Abstract Purpose To determine the osmolality of various viscoelastic substances. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, and Institute for Medical Device Testing, Memmingen, Germany. Methods The analysis was carried out according to the European Pharmacopoeia by means of a calibrated osmometer using the freezing-point depression method. Each syringe was analyzed as a duplicate analysis. Results Mean osmolalities (mOsmol/kg) of the sodium hyaluronate viscoelastic substances were Allervisc® 299; Allervisc® Plus 307; Amvisc® Plus 335; AMO Vitrax® 284; Biolon® 279; Dispasan® 311; Dispasan® Plus 314; Healon® 295; Healon GV® 312; Healon®5 322; HYA-Ophtal® 376; M…

medicine.medical_specialtyCorneal endotheliumAnterior ChamberSodium hyaluronateCataract ExtractionMethylcelluloseOsmolar ConcentrationInjectionsCorneachemistry.chemical_compoundHypromellose DerivativesOsmometerOphthalmologymedicineHumansIn patientProtease InhibitorsHyaluronic AcidViscoelastic SubstancesOsmotic concentrationbusiness.industryOsmolar ConcentrationReproducibility of ResultsHypromellose DerivativesSensory SystemsOphthalmologychemistrySurgerybusinessJournal of cataract and refractive surgery
researchProduct

Optical analysis to predict outcomes after implantation of a double intraocular lens magnification device.

2007

Purpose To analyze the effect of different optical parameters of the eye on the outcomes of implantation of a double intraocular lens (IOL) magnification device in patients with low vision. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods The eye's refraction and magnification before and after surgery were evaluated using a theoretical eye model based on paraxial optics approximation. Four parameters on which refraction and magnification are dependent were evaluated: anterior chamber depth (ACD), axial length (AL), mean keratometry (Km), and the distance between the 2 implanted IOLs. The 4 variables were analyzed separately in the first stage. Next, different combi…

medicine.medical_specialtyOptics and PhotonicsBiometrygenetic structuresAnterior Chambermedicine.medical_treatmentMagnificationVision LowIntraocular lensEyeRefraction Ocularlaw.inventionOpticsLens Implantation IntraocularlawOphthalmologymedicineMyopiaHumansIn patientPhysicsLenses IntraocularKeratometerbusiness.industryParaxial approximationModels TheoreticalMagnification deviceRefractioneye diseasesSensory SystemsLow visionOphthalmologyHyperopiaTreatment OutcomeSurgerysense organsbusinessJournal of cataract and refractive surgery
researchProduct

Changes in higher-order aberrations after implantation of a foldable iris-claw lens in myopic phakic eyes

2006

Purpose To evaluate the change in higher-order aberrations (HOAs) after implantation of a foldable iris-claw phakic intraocular lens (pIOL) in myopic eyes. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods This prospective nonrandomized comparative self-controlled trial included 41 eyes that had implantation of a foldable iris-claw pIOL between July 2003 and November 2004. All patient data for HOAs (Zernike coefficient) were measured and calculated using the same pupil size preoperatively and postoperatively, and the root-mean-square (RMS) wavefront error was calculated. Examinations were performed preoperatively as well as 1 week and 3, 6, and 12 m…

medicine.medical_specialtyRefractive errorgenetic structuresAnterior ChamberEye diseaseVisual AcuityIrisPhakic intraocular lensCorneaVision disorderLens Implantation IntraocularOphthalmologyLens CrystallineMyopiaHumansMedicineProspective StudiesIris clawDioptreLenses Intraocularbusiness.industryRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsOphthalmologyAberrations of the eyemedicine.anatomical_structureLens (anatomy)Silicone ElastomersSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Lens implant selection with absence of capsular support.

2001

If contact lens or spectacle correction is not viable, little debate exists that the secondary placement of an intra-ocular lens (IOL) is the method of choice in the absence of capsular support. The choice of IOL mainly depends on the preoperative status of the eye (eg, aphakia in children) and the selected location for the implant. Theoretically, there are several IOL implantation approaches in cases without capsular support: an angle-supported anterior chamber (AC) IOL, an iris-fixated ACIOL, an iris-sutured or iris-fixated posterior chamber (PC) IOL and a transsclerally sutured PCIOL. No consensus exists, however, on the indications as well as on the relative safety and efficacy of these…

medicine.medical_specialtygenetic structuresLens Capsule CrystallineGlaucomaProsthesis DesignAphakiaLens Implantation IntraocularAnterior Eye SegmentCorneaOphthalmologyProsthesis FittingMedicineHumansLenses Intraocularbusiness.industrySuture TechniquesGeneral Medicinemedicine.diseaseeye diseasesAnterior Eye SegmentContact lensOphthalmologymedicine.anatomical_structureAniridiasense organsImplantbusinessShallow anterior chamberCurrent opinion in ophthalmology
researchProduct

The "sandwich technique" for iris-fixated phakic intraocular lens implantation.

2006

ABSTRACT PURPOSE: To describe a new technique of implantation of the Artisan/Verisyse phakic intraocular lens (PIOL). METHODS: After PIOL insertion into the anterior chamber, a bolus of a high viscosity ophthalmic viseosurgical device (OVD) is placed over the optic, separating it widely from the endothelium. RESULTS: The technique decreases the chance of endothelial damage during enclavation. CONCLUSIONS: A bolus of a high viscosity OVD placed on the anterior surface of the Artisan/Verisyse PIOL may make enclavation safer. [J Refract Surg. 2006;22:96-98.]

medicine.medical_specialtygenetic structuresbusiness.industryAnterior Chambermedicine.medical_treatmentSuture TechniquesIrisIntraocular lensAnterior surfacePhakic intraocular lensRefractive Surgical ProceduresOphthalmologyLens Implantation IntraocularOphthalmologymedicineHumansSurgerybusinessSandwich techniqueJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct