Search results for "aortic valve stenosis"

showing 10 items of 60 documents

Association between asymptomatic carotid atherosclerosis and degenerative aortic stenosis.

2012

OBJECTIVE: Degenerative aortic stenosis shows similarities with atherosclerosis. To confirm the hypothesis that aortic stenosis is an "atherosclerosis-like" disease, we investigated the association between degenerative aortic stenosis and atherosclerosis of carotid arteries. METHODS: We studied 270 consecutive patients, 135 with degenerative aortic stenosis (trans-aortic peak velocity ≥ 2 m/sec) and other 135 subjects without aortic valve disease. All patients underwent echocardiography and ultrasound scan of the supra-aortic trunks to assess the presence of plaque and/or intima-media thickening (IMT). RESULTS: Atherosclerosis of carotid arteries (IMT and plaque) was significantly more freq…

Carotid Artery DiseasesMalemedicine.medical_specialtyCarotid Intima-Media ThicknessRisk AssessmentSeverity of Illness IndexAsymptomaticPredictive Value of TestsRisk FactorsInternal medicineSeverity of illnessOdds RatiomedicineHumansAgedAsymptomatic DiseasesAged 80 and overChi-Square Distributionbusiness.industryCase-control studyAortic Valve StenosisOdds ratiomedicine.diseaseSettore MED/11 - Malattie Dell'Apparato CardiovascolarePlaque AtheroscleroticStenosisCarotid ArteriesItalyCarotid atherosclerosis aortic stenosisCase-Control StudiesPredictive value of testsAsymptomatic DiseasesLinear Modelscardiovascular systemCardiologyFemaleRadiologymedicine.symptomCardiology and Cardiovascular MedicinebusinessChi-squared distribution
researchProduct

Aortic valve stenosis: Treatments options in elderly high-risk patients

2016

Not available

Elderly patientsTranscatheter aortic valve implantationMinimaly invasive surgerySymposium: Transcatheter aortic valve implantationAortic valve stenosiAortic valve stenosis; Elderly patients; Minimaly invasive surgery; Risck stratification; Transcatheter aortic valve implantation; Cardiology and Cardiovascular Medicine; Geriatrics and GerontologyAortic valve stenosisGeriatrics and GerontologyRisck stratificationCardiology and Cardiovascular MedicineElderly patient
researchProduct

Local Application of Leptin Antagonist Attenuates Angiotensin II–Induced Ascending Aortic Aneurysm and Cardiac Remodeling

2016

Background Ascending thoracic aortic aneurysm ( ATAA ) is driven by angiotensin II (Ang II ) and contributes to the development of left ventricular ( LV ) remodeling through aortoventricular coupling. We previously showed that locally available leptin augments Ang II ‐induced abdominal aortic aneurysms in apolipoprotein E–deficient mice. We hypothesized that locally synthesized leptin mediates Ang II ‐induced ATAA . Methods and Results Following demonstration of leptin synthesis in samples of human ATAA associated with different etiologies, we modeled in situ leptin expression in apolipoprotein E–deficient mice by applying exogenous leptin on the surface of the ascending aorta. This treatm…

LeptinMale0301 basic medicineAortic valveTranslational StudiesMice Knockout ApoEaortic valve stenosisangiotensin II030204 cardiovascular system & hematologyLeft ventricular hypertrophyVascular MedicineMiceAortic aneurysm0302 clinical medicineVasoconstrictor AgentsMedicineCells CulturedOriginal ResearchAged 80 and overVentricular RemodelingLeptindigestive oral and skin physiologyMiddle Agedleft ventricular hypertrophymedicine.anatomical_structureAortic ValveAortic valve stenosiscardiovascular systemCardiologyFemaleHypertrophy Left VentricularCardiology and Cardiovascular Medicineaortic aneurysmhormones hormone substitutes and hormone antagonistsAdultmedicine.medical_specialtyvascular remodelingThoracic aortic aneurysmYoung Adult03 medical and health sciencesVascular Stiffnessmedicine.arteryInternal medicineAscending aortaAnimalsHumansAgedCell ProliferationAortic Aneurysm Thoracicbusiness.industryleptin antagonistmedicine.diseaseAneurysmAngiotensin II030104 developmental biologyEndocrinologyAnimal Models of Human DiseaseValvular Heart DiseasebusinessJournal of the American Heart Association
researchProduct

Improvement in Risk Stratification in Transcatheter Aortic Valve Implantation Using a Combination of the Tumor Marker CA125 and the Logistic EuroSCORE

2017

Conventional risk scores have not been accurate in predicting peri- and postprocedural risk of patients undergoing transcatheter aortic valve implantation (TAVI). Elevated levels of the tumor marker carbohydrate antigen 125 (CA125) have been linked to adverse outcomes after TAVI. We studied the additional value of CA125 to that of the EuroSCORE in predicting long-term mortality after TAVI.During a median follow-up of 59 weeks, 115 of 422 patients (27%) died after TAVI. Mortality was higher with elevated CA125 (30 U/mL) and EuroSCORE (median) (47% vs 20%, P.001 and 38% vs 16%, P.001, respectively). In the multivariable analysis, CA125 (30 U/mL) remained an independent predictor of mortality …

MaleLogistic euroscoremedicine.medical_specialtyPoor prognosisTranscatheter aortic610 Medicine & health030204 cardiovascular system & hematologyRisk AssessmentSeverity of Illness Index2705 Cardiology and Cardiovascular MedicineTranscatheter Aortic Valve Replacement03 medical and health sciences0302 clinical medicineInternal medicineHumansMedicineProspective Studies030212 general & internal medicineAgedTumor markerbusiness.industryHazard ratioMembrane ProteinsEuroSCOREAortic Valve StenosisGeneral MedicinePrognosisConfidence intervalCA-125 AntigenRisk stratification10209 Clinic for CardiologyCardiologyFemalebusinessRevista Española de Cardiología (English Edition)
researchProduct

Simulation study of transcatheter heart valve implantation in patients with stenotic bicuspid aortic valve

2019

Bicuspid aortic valve (BAV) anatomy has routinely been considered an exclusion in the setting of transcatheter aortic valve implantation (TAVI) because of the large dimension of the aortic annulus having a more calcified, bulky, and irregular shape. The study aims to develop a patient-specific computational framework to virtually simulate TAVI in stenotic BAV patients using the Edwards SAPIEN 3 valve (S3) and its improved version SAPIEN 3 Ultra and quantify stent frame deformity as well as the severity of paravalvular leakage (PVL). Specifically, the aortic root anatomy of n.9 BAV patients who underwent TAVI was reconstructed from pre-operative CT imaging. Crimping and deployment of S3 fram…

MaleModels Anatomicmedicine.medical_treatment02 engineering and technology030218 nuclear medicine & medical imaging0302 clinical medicineBicuspid aortic valveBicuspid Aortic Valve DiseaseImage Processing Computer-AssistedCardiac skeletonPrecision MedicineAged 80 and overCardiac cycleSettore ING-IND/34 - Bioingegneria IndustrialeComputer Science Applicationsmedicine.anatomical_structureSurgery Computer-Assistedcardiovascular systemCardiologyFemalemedicine.symptommedicine.medical_specialtyBicuspid aortic valve0206 medical engineeringFinite Element AnalysisBiomedical EngineeringDiastoleTranscatheter Aortic Valve Replacement03 medical and health sciencesFluid-solid interactionInternal medicinePreoperative CaremedicineDeformityHumansIn patientHeart valveAgedRetrospective StudiesTranscatheter aortic valve implantationbusiness.industryStentComputational BiologyFinite-element analysiAortic Valve Stenosismedicine.disease020601 biomedical engineeringbusinessTomography X-Ray ComputedEchocardiography Transesophageal
researchProduct

Compliance and Pulse Wave Velocity Assessed by MRI Detect Early Aortic Impairment in Young Patients With Mutation of the Smooth Muscle Myosin Heavy C…

2008

Purpose To evaluate aortic elasticity with MRI on young asymptomatic individuals with mutation of the smooth muscle myosin heavy chain in whom aortic enlargement is not present. Materials and Methods Aortic compliance, aortic distensibility, and pulse wave velocity (PWV) were semiautomatically measured from MRI in 8 asymptomatic subjects having a mutation of the MYH11 gene (M+) and 21 nonmutated relatives (M−) of similar age, sex, and blood pressure characteristics. Results Despite a similar aortic diameter in both groups, the aortic compliance and distensibility were significantly lower in M+ subjects compared with M− (0.84 ± 0.33 versus 2.03 ± 0.54 mm2/mmHg, 1.18 ± 0.62 10−3 versus 5.11 ±…

MalePulsatile flow030204 cardiovascular system & hematology030218 nuclear medicine & medical imaging0302 clinical medicinemagnetic resonance imaginggeneticsPulse wave velocityComputingMilieux_MISCELLANEOUSmedicine.diagnostic_test[ INFO.INFO-IM ] Computer Science [cs]/Medical ImagingPrognosisPulsatile FlowAortic valve stenosiscardiovascular systemCardiologyElasticity Imaging TechniquesFemalemedicine.symptomAlgorithmsBlood Flow VelocityAdultmedicine.medical_specialtypulse wave velocityAortic Valve InsufficiencySensitivity and SpecificityAsymptomaticYoung Adult03 medical and health sciencesElastic Modulusmedicine.arteryInternal medicineImage Interpretation Computer-Assistedmedicine[INFO.INFO-IM]Computer Science [cs]/Medical ImagingHumansGenetic Predisposition to DiseaseRadiology Nuclear Medicine and imagingAortaMyosin Heavy ChainsReceiver operating characteristicbusiness.industryReproducibility of ResultsMagnetic resonance imagingAortic Valve StenosisImage Enhancementmedicine.diseaseaortaBlood pressureMutationelasticitybusiness
researchProduct

Outcomes of Patients With Asymptomatic Aortic Stenosis Followed Up in Heart Valve Clinics

2018

International audience; Importance - The natural history and the management of patients with asymptomatic aortic stenosis (AS) have not been fully examined in the current era. Objective - To determine the clinical outcomes of patients with asymptomatic AS using data from the Heart Valve Clinic International Database. Design, setting, and participants - This registry was assembled by merging data from prospectively gathered institutional databases from 10 heart valve clinics in Europe, Canada, and the United States. Asymptomatic patients with an aortic valve area of 1.5 cm2 or less and preserved left ventricular ejection fraction (LVEF) greater than 50% at entry were considered for the prese…

MaleRegistrieUnited StateCanadamedicine.medical_specialty030204 cardiovascular system & hematologyAsymptomaticSudden deathDisease-Free Survival03 medical and health sciences0302 clinical medicineAortic valve replacementRetrospective StudieInternal medicinemedicineHumansProspective StudiesRegistries030212 general & internal medicineHeart valveWatchful WaitingProspective cohort studyRetrospective StudiesAgedAged 80 and overAsymptomatic DiseaseEjection fractionbusiness.industryDisease ManagementAortic Valve StenosisMiddle Agedmedicine.diseaseAortic Valve StenosiUnited States3. Good healthEuropeProspective StudieStenosisDeath Sudden Cardiacmedicine.anatomical_structureAortic valve stenosisAsymptomatic DiseasesCardiology[SDV.IB]Life Sciences [q-bio]/BioengineeringFemalemedicine.symptombusinessCardiology and Cardiovascular MedicineHuman
researchProduct

Valve prosthesis-patient mismatch: hemodynamic, echocardiographic and clinical consequences

2011

OBJECTIVES: The purpose is to evaluate in vivo at rest and under stress conditions hemodynamic performance of the small size St. Jude Medical Regent (SJMR) prosthetic valve in patients with a body surface area (BSA) of 1.8 ± 0.11 m(2) and to define the role of valve prosthesis- patient mismatch on left ventricular mass regression following aortic valve replacement. METHODS: We evaluated 25 cases (12 males and 13 females, mean age 65.2 ± 8 years) of aortic valve replacement (17 mm SJMR in three cases and 19 mm SJMR in 22 cases). All the patients underwent at rest Doppler echocardiography before and after surgery and both basal and dobutamine stress echocardiography (DSE) at follow-up. The me…

MaleTime FactorsBody Surface Areamedicine.medical_treatmentLeft ventricular maHemodynamicsDoppler echocardiographyVentricular Function LeftValve replacementAortic valve replacementDobutamineCardiac skeletonBody surface areaHeart Valve Prosthesis ImplantationEjection fractionmedicine.diagnostic_testVentricular RemodelingMiddle AgedEchocardiography DopplerTreatment OutcomeAortic ValveHeart Valve ProsthesisCardiologyFemaleHypertrophy Left VentricularCardiology and Cardiovascular MedicineEchocardiography StressPulmonary and Respiratory Medicinemedicine.medical_specialtyProsthesis DesignPreoperative carePredictive Value of TestsInternal medicineProsthesis-patient mismatch; Left ventricular mass; Effective orifice area; DobutaminemedicineHumansAgedRetrospective StudiesChi-Square Distributionbusiness.industryHemodynamicsProsthesis-patient mismatchStroke VolumeSettore MED/23 - Chirurgia CardiacaAortic Valve StenosisRecovery of Functionmedicine.diseaseEffective orifice areaSurgerybusiness
researchProduct

Tumor Marker Carbohydrate Antigen 125 Predicts Adverse Outcome After Transcatheter Aortic Valve Implantation

2013

ObjectivesThis study sought to predict the value of tumor marker carbohydrate antigen 125 (CA125) before and after transcatheter aortic valve implantation (TAVI) for all-cause death and a composite endpoint of death, admission for heart failure, myocardial infarction, and stroke (major adverse cardiac events [MACE]).BackgroundRisk stratification after TAVI remains challenging. The use of biomarkers in this setting represents an unmet need.MethodsCA125 was measured in 228 patients before and after TAVI. The association with outcomes was assessed using parametric Cox regression and joint modeling for baseline and longitudinal analyses, respectively. CA125 was evaluated as logarithm transforma…

Malemedicine.medical_specialtyCardiac CatheterizationTime FactorsAortic Valve InsufficiencyMyocardial InfarctionKaplan-Meier EstimateRisk AssessmentCA125Interquartile rangeRisk FactorsInternal medicineMedicineHumansMyocardial infarctionLongitudinal StudiesRegistriesStroketranscatheter aortic valve implantationTumor markerAgedProportional Hazards ModelsAged 80 and overHeart FailureHeart Valve Prosthesis ImplantationProportional hazards modelbusiness.industryMembrane ProteinsAortic Valve Stenosismedicine.diseasejoint modelingHospitalizationStrokeLogistic ModelsTreatment OutcomeCardiovascular DiseasesHeart failureCA-125 AntigenMultivariate AnalysisCardiologybiomarkerBiomarker (medicine)FemaleprognosisbusinessCardiology and Cardiovascular MedicineMaceBiomarkersJACC: Cardiovascular Interventions
researchProduct

Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement

2013

Background— Aortic root rupture is a major concern with balloon-expandable transcatheter aortic valve replacement (TAVR). We sought to identify predictors of aortic root rupture during balloon-expandable TAVR by using multidetector computed tomography. Methods and Results— Thirty-one consecutive patients who experienced left ventricular outflow tract (LVOT)/annular/aortic contained/noncontained rupture during TAVR were collected from 16 centers. A caliper-matched sample of 31 consecutive patients without annular rupture, who underwent pre-TAVR multidetector computed tomography served as a control group. Multidetector computed tomography assessment included short- and long-axis diameters an…

Malemedicine.medical_specialtyCardiac CatheterizationTranscatheter aorticAortic rootmedicine.medical_treatmentAortic Rupturemultidetector computed tomographySettore MED/11 - Malattie dell'Apparato CardiovascolareCohort StudiesValve replacementPredictive Value of TestsRisk FactorsPhysiology (medical)Internal medicineMultidetector computed tomographymedicine80 and overVentricular outflow tractHumanscardiovascular diseasesannular calcification; annular rupture; multidetector computed tomography; transcatheter heart valves; Aged; Aged 80 and over; Angioplasty Balloon; Aortic Rupture; Aortic Valve; Aortic Valve Stenosis; Calcinosis; Cohort Studies; Female; Heart Valve Prosthesis Implantation; Humans; Logistic Models; Male; Predictive Value of Tests; Risk Factors; Tomography X-Ray Computed; Cardiac CatheterizationTomographyAgedAged 80 and overHeart Valve Prosthesis Implantationbusiness.industrySinotubular JunctionAngioplastyCalcinosisAortic Valve Stenosismedicine.diseaseX-Ray ComputedBalloon expandable stentLogistic Modelstranscatheter heart valvesAortic ValveCardiologycardiovascular systemannular ruptureFemaleRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedAngioplasty BalloonBalloonCalcificationannular calcification
researchProduct