Search results for "aortic valve"
showing 10 items of 179 documents
Usefulness of Clopidogrel Loading in Patients Who Underwent Transcatheter Aortic Valve Implantation (from the BRAVO-3 Randomized Trial)
2018
P2Y12-inhibitor initiation with clopidogrel using a loading dose (LD) versus no LD (NLD) provides more rapid inhibition of platelet activation and reduced risk of ischemic events after coronary stenting. Whether a similar beneficial effect is achieved in the setting of transcatheter aortic valve implantation (TAVI) is unknown. We evaluate the effects of preprocedural clopidogrel LD versus no NLD on 48-hour and 30-day clinical outcomes after TAVI. In the BRAVO-3 trial, 802 patients with severe aortic stenosis who underwent transfemoral TAVI were randomized to intraprocedural anticoagulation with bivalirudin or unfractionated heparin. Administration of clopidogrel LD was left to the discretio…
Immunoglobulin G4-Related Aortitis and Severe Aortic Valve Stenosis Treated With Transcatheter Aortic Valve Replacement and Immunosuppression.
2021
Abstract IgG4-related disease is an immune-mediated fibro-inflammatory disorder with multisystemic involvement. Aortitis and peri-aortitis are the most common cardiovascular manifestations of the disease. We present the case of a 65-year-old man with symptomatic severe aortic stenosis and concomitant IgG4 aortitis. The diagnosis was confirmed by IgG4 serum levels, positive positron emission computed tomography (PET-CT) scans, and pathology from mediastinal dissection. Surgical aortic valve replacement (SAVR) was unfeasible owing to extensive mediastinal fibrosis, and transcatheter aortic valve replacement (TAVR) was successfully performed. As ascending aorta access for SAVR in IgG4 aortitis…
Differential Prognostic Value of Galectin-3 According to Carbohydrate Antigen 125 Levels in Transcatheter Aortic Valve Implantation
2019
Galectin-3 (Gal-3) and carbohydrate antigen 125 (CA125) have been associated with adverse outcomes after transcatheter aortic valve implantation (TAVI). Experimental data have suggested a potential molecular interaction. Therefore, we assessed the association of Gal-3 and CA125 with prognosis after TAVI.A total of 439 patients were enrolled. The primary endpoint was a composite of all-cause mortality or readmission for worsening heart failure after TAVI.The primary endpoint occurred in 16.4%. Gal-3 was dichotomized at ≥ 8.71 ng/mL into elevated and not elevated. Gal-3 was elevated in 31.9% and was associated with a higher risk of the primary endpoint (25% vs 12.4%, HR, 2.26; P.001). After m…
Comparison of Carbohydrate Antigen 125 and N-Terminal Pro-Brain Natriuretic Peptide for Risk Prediction After Transcatheter Aortic Valve Implantation
2017
Elevated carbohydrate antigen 125 (CA125) and N-terminal pro-brain natriuretic peptide (NTproBNP) have been associated with adverse outcome after transcatheter aortic valve implantation (TAVI). This study performs a comparison of both biomarkers for prognosis after TAVI. The study includes 363 patients. The primary end point was all-cause death or readmission for worsening congestive heart failure within 1 year after TAVI, and this end point occurred in 16% of the population. The optimal cutoff to predict the primary end point was 18.4 U/ml for CA125 and 2,570 ng/L for NTproBNP. Elevated CA125 levels were present in 52% and were associated with a higher rate of the primary end point (27% vs…
Beta-3 adrenergic receptor overexpression reverses aortic stenosis-induced heart failure and restores balanced mitochondrial dynamics
2022
25 p.-7 fig.
Combination of aztreonam, ceftazidime–avibactam and amikacin in the treatment of VIM-1 Pseudomonas aeruginosa ST235 osteomyelitis
2021
Abstract We describe a challenging case of patient with metallo-beta-lactamase-producing Pseudomonas aeruginosa sternal osteomyelitis following aortic valve replacement with biological prosthesis. The strain exhibited a multidrug-resistance phenotype carrying the blaVIM-1 gene and belonged to the high-risk clone sequence type ST235. The patient was successfully treated with surgical debridement plus antibiotic therapy with ceftazidime/avibactam, aztreonam, and amikacin. Time-kill curves showed that this triple antibiotic combination at 1 × MIC was strongly synergic after 8 h, achieving 99.9% killing and maintaining this until 48 h.
Direct measurement of left ventricular outflow tract by transthoracic real-time 3D-echocardiography increases accuracy in assessment of aortic valve …
2007
Evaluation of aortic valve stenosis is a major clinical application of echocardiography. The widely employed continuity equation requires determination of the left ventricular outflow tract (LVOT) area. We aimed at testing whether direct area measurement in a volume data set is superior to conventional calculation from the LVOT diameter.We performed LVOT measurement in 20 normal subjects and 83 patients with moderate to severe aortic stenosis with a transthoracic real-time three-dimensional echocardiography (3D-TTE) technique in two systolic frames. The off-line 3D-evaluation allows full choice of section planes within the acquired volume data set. The aortic valve area was calculated from …
The Endothelial Transcription Factor ERG Mediates a Differential Role in the Aneurysmatic Ascending Aorta with Bicuspid or Tricuspid Aorta Valve: A P…
2022
The pathobiology of ascending aorta aneurysms (AAA) onset and progression is not well understood and only partially characterized. AAA are also complicated in case of bicuspid aorta valve (BAV) anatomy. There is emerging evidence about the crucial role of endothelium-related pathways, which show in AAA an altered expression and function. Here, we examined the involvement of ERG-related pathways in the differential progression of disease in aortic tissues from patients having a BAV or tricuspid aorta valve (TAV) with or without AAA. Our findings identified ERG as a novel endothelial-specific regulator of TGF-β-SMAD, Notch, and NO pathways, by modulating a differential fibrotic or calcified A…
Impact of Aortic Diameter Measurements at Three Anatomical Landmarks on Left Ventricular Output Calculation in Neonates
2021
OBJECTIVES To assess reproducibility and accuracy of left ventricular output (LVO) quantifications in neonates, when left ventricular outflow tract diameter (LVOTD) was measured at the hinges of the aortic valve (AV), at the aortic sinus (AS), and at the sinotubular junction (STJ). METHODS This was an observational study. In the first cohort of very preterm neonates, we assessed intraobserver and interobserver repeatability of LVOTD measured at the AV, AS, and STJ and of the corresponding LVO. In the second cohort of older neonates, we compared paired LVO measurements by echo and magnetic resonance imaging (MRI). RESULTS In the first cohort of 48 neonates, mean (standard deviation) weight a…
Prognostic value of the ratio between prothesis area and indexed annulus area measured by multiSlice-CT for transcatheter aortic valve implantation p…
2016
Background Postprocedural aortic regurgitations following transcatheter aortic valve implantation (TAVI) procedures remain an is- sue. Benefit of oversizing strategies to prevent them isn’t well established. We compared different level of oversizing in our cohort of con- secutive patients to address if severe oversizing compared to normal sizing had an impact on post-procedural outcomes. Methods From January 2010 to August 2013, consecutive patients were referred for TAVI with preoperative Multislice-CT (MSCT) and the procedures were achieved using Edwards Sapien® or Corevalve devices®. Retrospectively, according to pre-procedural MSCT and the valve size, pa- tients were classified into thr…