Search results for "armo"

showing 10 items of 1364 documents

Constraints on the spatial variation of Planck constant

2021

AbstractInspired by recently published researches, we present two protocols for setting an upper limit to the claimed variation of$$\hbar $$ħupon the position. The protocols, both within today state of art, involve the use of two delayed laser pulses driving an atom. The distinct positions of the laboratory, due to the Earth motion, affects$$\hbar $$ħand hence the atomic dynamics. The first protocol measures the difference in population of the atomic ground state while the second one the red-shift of the harmonics emitted by the atom in the two moments of the experiment. The protocols improve the reported upper limit of$$\varDelta \hbar /\hbar $$Δħ/ħ. The theory shows that$$\hbar (\varvec{r…

Fluid Flow and Transfer ProcessesPhysicseducation.field_of_studySettore FIS/02 - Fisica Teorica Modelli E Metodi MatematiciField (physics)PopulationGeneral Physics and Astronomyvariation of physical constantsPlanck constantQuantum mechanicsymbols.namesakePosition (vector)Quantum mechanicsHarmonicsAtomsymbolsLimit (mathematics)Ground stateeducationThe European Physical Journal Plus
researchProduct

Selective binding to monoamine oxidase A: in vitro and in vivo evaluation of (18)F-labeled β-carboline derivatives.

2015

In this study we synthesized four different (18)F-labeling precursors for the visualization of the monoamino oxidase A using harmol derivatives. Whereas two are for prosthetic group labeling using [(18)F]fluoro-d2-methyl tosylate and 2-[(18)F]fluoroethyl-tosylate, the other three precursors are for direct nucleophilic (18)F-labeling. Additionally the corresponding reference compounds were synthesized. The syntheses of [(18)F]fluoro-d2-methyl-harmol and 2-[(18)F]fluoroethyl-harmol were carried out using harmol as starting material. For direct nucleophilic (18)F-labeling of the tracers carrying oligoethyled spacers (PEG), a toluenesulfonyl leaving group was employed. The radiolabeling, purifi…

Fluorine RadioisotopesStereochemistryClinical BiochemistryPharmaceutical ScienceAlkylationIn Vitro TechniquesBiochemistryRats Sprague-Dawleychemistry.chemical_compoundDrug StabilityIn vivoDrug DiscoveryPEG ratioAnimalsHumansMolecular BiologyMonoamine OxidaseHarmolChemistryOrganic ChemistryLeaving groupLigand (biochemistry)In vitroRatsIsotope LabelingPositron-Emission TomographyMolecular MedicineRadiopharmaceuticalsSelectivityCarbolinesBioorganicmedicinal chemistry
researchProduct

Vibrational spectra and force constants of symmetric tops

1983

The infrared spectrum of H3SiI in the 800–1050 cm-1 region has been recorded with a resolution of 0·04 cm-1 and rotationally analysed. Features related to the Fermi resonance between v 5 and v 3 + v 6 and to the Coriolis x, y resonance between v 2 and v 5 have been explained, and a set of vibration-rotation parameters for the three bands has been determined by least-squares calculations, σ(J, K) = 9·4 × 10-3 cm-1. The Fermi resonance matrix element |W 356| is found to be 3·7859(7) cm-1 and the vibrational frequencies are v 2 0 = 904·551(1), v 5 0 = 941·0746(8) and (v 3 + v 6)0 = 953·688(3) cm-1. The anharmonicity constant, x 36 = -1·745(9) cm-1, has been determined. Comparison is made with …

Force constantInfraredChemistryAnharmonicityResolution (electron density)BiophysicsAnalytical chemistryResonanceCondensed Matter PhysicsMatrix elementFermi resonancePhysical and Theoretical ChemistryAtomic physicsMolecular BiologyVibrational spectraMolecular Physics
researchProduct

Glass Transition and Glass Dynamics

2014

The transition from an undercooled liquid towards a glass (glass transition) is introduced and discussed in terms of mode-coupling theory. It is demonstrated that mode-coupling theory leads to a two-step relaxation scenario near the transition with time-critical exponents, which characterize the two relaxation steps (beta and alpha relaxation). The anomalous vibrational properties of a disordered solid (glass) is explained in terms of a model with spatially fluctuating harmonic force constants.

Force constantMaterials scienceCondensed matter physicsCritical lineBeta (plasma physics)Dynamics (mechanics)HarmonicRelaxation (physics)Boson peakGlass transitionCondensed Matter::Disordered Systems and Neural Networks
researchProduct

Estimation of formamide harmonic and anharmonic modes in the Kohn-Sham limit using the polarization consistent basis sets.

2010

Formamide harmonic and anharmonic frequencies of fundamental vibrations in the gas phase and in several solvents were successfully estimated in the B3LYP Kohn-Sham complete basis set limit (KS CBS). CBS results were obtained by extrapolating a power function (two-parameter formula) to the results calculated with polarization-consistent basis sets. Anharmonic corrections using the second order perturbation treatment (PT2) and hybrid B3LYP functional combined with polarization consistent pc-n (n = 0, 1, 2, 3, 4) and several Pople’s basis sets were analyzed for all fundamental formamide vibrational modes in the gas phase and solution. Solvent effects were modeled within a PCM method. The anhar…

FormamideAcetonitrilesMolecular ConformationAnharmonic vibrationSolvent effectMolecular physicsCatalysisInorganic ChemistryAcetonechemistry.chemical_compoundComputational chemistryScissoringHexanesComputer SimulationDimethyl SulfoxideHarmonic vibrationPhysical and Theoretical ChemistryPhysics::Chemical PhysicsCarbon TetrachlorideBasis setQuantitative Biology::BiomoleculesOriginal PaperFormamidesOrganic ChemistryAnharmonicityWaterComplete basis set limitFormamideComputer Science ApplicationsComputational Theory and MathematicschemistryModels ChemicalMolecular vibrationHarmonicSolventsThermodynamicsFermi resonanceChloroformGasesSolvent effectsJournal of molecular modeling
researchProduct

Second-harmonic free-induction decay in a two-level spin system

1983

Free induction decayPhysicsQuantum electrodynamicsSpin systemHarmonicPhysical Review A
researchProduct

Singular factorizations, self-adjoint extensions, and applications to quantum many-body physics

2006

We study self-adjoint operators defined by factorizing second order differential operators in first order ones. We discuss examples where such factorizations introduce singular interactions into simple quantum mechanical models like the harmonic oscillator or the free particle on the circle. The generalization of these examples to the many-body case yields quantum models of distinguishable and interacting particles in one dimensions which can be solved explicitly and by simple means. Our considerations lead us to a simple method to construct exactly solvable quantum many-body systems of Calogero-Sutherland type.

Free particlePure mathematicsGeneralizationFOS: Physical sciencesGeneral Physics and AstronomyStatistical and Nonlinear PhysicsMathematical Physics (math-ph)Type (model theory)Differential operatorSimple (abstract algebra)QuantumHarmonic oscillatorSelf-adjoint operatorMathematical Physics
researchProduct

Improvement of Hall Effect Current Transducer Metrological Performances in the Presence of Harmonic Distortion

2010

The performance of Hall effect current transducers (HECTs), under distorted waveform conditions, is usually characterized by means of a frequency response test. In this paper, it was investigated if frequency response is able to correctly evaluate the ratio and the phase errors under distorted conditions. Two HECTs, with the accuracy class level of 1% and 0.5%, respectively, were experimentally characterized under two conditions: 1) sinusoidal excitation with frequencies ranging from 50 to 750 Hz, which is the well-known frequency response test, and 2) nonsinusoidal excitation using fundamental frequency and one harmonic with adjusted amplitude and phase shift. It was found that ratio and p…

Frequency responseElectric current measurementCurrent measurement current transducer frequency response hall effect devices harmonic distortion power system harmonics.AcousticsTransducersPhase (waves)GyratorsNon-sinusoidal excitationHarmonic distortionAccuracy levelFundamental frequenciesHarmonic analysisPhase errorElectric currentsError compensationFrequency responseFrequency response testsWaveformSinusoidal excitationsPhase shiftElectrical and Electronic EngineeringInstrumentationPhysicsTotal harmonic distortionElectric power distributionHall effectCurrent measurementsMetrological performanceCurrent transducerFundamental frequencyLight measurementAmplitudeAccuracy classHarmonicsMagnetic field effectsHarmonicHarmonic amplitudeSettore ING-INF/07 - Misure Elettriche E ElettronicheDistorted waveformsHarmonic componentsHall effect devicesIEEE Transactions on Instrumentation and Measurement
researchProduct

Rogowski coil current transducer compensation method for harmonic active power error

2015

Abstract In the harmonic active power measurement, the highest uncertainties are generally introduced by the current and voltage transducers. In a previous paper, the authors showed that the current transformer (CT) can introduce significant errors in such measurement, especially if the phase shift between voltage and current is close to ±90°. In such condition the errors on harmonic power measurement are mainly due to the CT phase displacement. This paper shows that better results can be achieved with more linear transducers, such as the Rogowski coil current transducers (RCCTs), whose metrological performance in distorted condition can be improved, by means of a proper compensation method…

Frequency responseEngineeringbusiness.industryApplied MathematicsAcousticsPower system harmonics Transducers Current transformers. Frequency response Power measurement Rogowski coilTransducersElectrical engineeringAC powerCondensed Matter PhysicsCurrent transformerRogowski coilCompensation (engineering)Power (physics)Current transformersFrequency responseHarmonicPower system harmonicsElectrical and Electronic EngineeringPower measurementbusinessInstrumentationSettore ING-INF/07 - Misure Elettriche E ElettronicheRogowski coilVoltage
researchProduct

Characterization of clamp-on current transformers under nonsinusoidal conditions

2009

This paper reports the performance of clamp-on current transformers under nonsinusoidal conditions. A set of experimental measurements helped to determine the ratio and the phase errors under two conditions: 1) sinusoidal excitation with frequencies from 45 to 1000 Hz and 2) nonsinusoidal excitation using the fundamental frequency and one harmonic, with adjusted phase shift. It was found that ratio and phase errors are affected by the phase angle between the harmonic and the fundamental and the harmonic amplitude. The effects of conductor location in the current transformer's window and of the air-gap width were also investigated. It was concluded that harmonic phase and ratio errors measur…

Frequency responseMaterials scienceElectric current measurementTransductorAcousticsErrorsTransducersPhase (waves)Energy Engineering and Power TechnologyClamp-on current transformers current transformers (CTs) frequency response power system harmonics transducers.Power transformersDistributed power generationElectric power systemsHarmonic analysisElectric power transmission networksClamp-on current transformersCurrent transformersFrequency responsePower electronicsFrequency measurementElectronic engineeringElectrical and Electronic EngineeringElectrical conductorTomographyComputed tomographyElectric power distributionElectric transformersCircuit faultsFault currentsFundamental frequencyComputerized tomographyFourier seriesCurrent measurementCurrent transformerDiagnostic radiographyElectric instrument transformersElectric frequency measurementPower system harmonicsMedical imagingCurrent transformers (CTs)Air gap (plumbing)Power transmissionElectric network analysisExcitation
researchProduct