Search results for "arseeni"

showing 6 items of 6 documents

Does Arsenic Contamination Affect DNA Methylation Patterns in a Wild Bird Population? : An Experimental Approach

2021

Pollutants, such as toxic metals, negatively influence organismal health and performance, even leading to population collapses. Studies in model organisms have shown that epigenetic marks, such as DNA methylation, can be modulated by various environmental factors, including pollutants, influencing gene expression, and various organismal traits. Yet experimental data on the effects of pollution on DNA methylation from wild animal populations are largely lacking. We here experimentally investigated for the first time the effects of early-life exposure to environmentally relevant levels of a key pollutant, arsenic (As), on genome-wide DNA methylation in a wild bird population. We experimentall…

environmental epigeneticsPopulationAnimals Wild010501 environmental sciencesBiology01 natural sciencesArticleArsenicecotoxicologyarseeniBirdsParus majorGene expressionEnvironmental ChemistryAnimalspollutionhaitalliset aineetEpigeneticseducationGene0105 earth and related environmental sciencesZinc fingerGeneticseducation.field_of_studyPlan_S-Compliant-TAympäristön saastuminenGeneral ChemistrytalitiainenDNA Methylation3. Good healthDNA-metylaatioArsenic contamination of groundwaterekotoksikologiaCpG site13. Climate actionepigenetiikkavillieläimetinternationalDNA methylationecological epigeneticsEnvironmental Pollutants
researchProduct

Observation of an ultralow-Q-value electron-capture channel decaying to 75As via a high-precision mass measurement

2022

A precise determination of the atomic mass of 75As has been performed utilizing the double Penning trap mass spectrometer, JYFLTRAP. The mass excess is measured to be −73035.519(42)keV/c2, which is a factor of 21 more precise and 1.3(9)keV/c2 lower than the adopted value in the newest Atomic Mass Evaluation (AME2020). This value has been used to determine the ground-state–to–ground-state electron-capture decay Q value of 75Se and β− decay Q value of 75Ge, which are derived to be 866.041(81) keV and 1178.561(65) keV, respectively. Using the nuclear energy-level data of 860.00(40) keV, 865.40(50) keV (final states of electron capture), and 1172.00(60) keV (final state of β− decay) for the exc…

massaspektrometrianeutriinothiukkasfysiikkaydinfysiikkaarseeni
researchProduct

Abundant and diverse arsenic‐metabolizing microorganisms in peatlands treating arsenic‐contaminated mining wastewaters

2020

Mining operations produce large quantities of wastewater. At a mine site in Northern Finland, two natural peatlands are used for the treatment of mining‐influenced waters with high concentrations of sulfate and potentially toxic arsenic (As). In the present study, As removal and the involved microbial processes in those treatment peatlands (TPs) were assessed. Arsenic‐metabolizing microorganisms were abundant in peat soil from both TPs (up to 108 cells gdw‐1), with arsenate respirers being about 100 times more abundant than arsenite oxidizers. In uninhibited microcosm incubations, supplemented arsenite was oxidized under oxic conditions and supplemented arsenate was reduced under anoxic con…

PeatkaivoksetArseniteschemistry.chemical_elementjätevesiBiologyWastewaterMicrobiologyMiningbiologinen puhdistusarseeniArsenic03 medical and health scienceschemistry.chemical_compoundSoilturvemaatGroundwaterEcology Evolution Behavior and SystematicsArsenicResearch ArticlesSoil Microbiology030304 developmental biologyArsenite0303 health sciences030306 microbiologyMicrobiotaArsenateAnoxic waters6. Clean waterOxygenBiodegradation EnvironmentalchemistryMicrobial population biologyEnvironmental chemistrymikro-organismitArsenateskaivosvesiMicrocosmSoil microbiologyOxidation-ReductionWater Pollutants ChemicalResearch ArticleEnvironmental Microbiology
researchProduct

Mass measurements of As, Se, and Br nuclei, and their implication on the proton-neutron interaction strength toward the N=Z line

2021

Mass measurements of the $^{69}$As, $^{70,71}$Se and $^{71}$Br isotopes, produced via fragmentation of a $^{124}$Xe primary beam at the FRS at GSI, have been performed with the multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) of the FRS Ion Catcher with an unprecedented mass resolving power of almost 1,000,000. For the $^{69}$As isotope, this is the first direct mass measurement. A mass uncertainty of 22 keV was achieved with only 10 events. For the $^{70}$Se isotope, a mass uncertainty of 2.6 keV was obtained, corresponding to a relative accuracy of $\delta$m/m = 4.0$\times 10^{-8}$, with less than 500 events. The masses of the $^{71}$Se and $^{71}$Br isotopes were measured…

nucl-thNuclear TheoryFOS: Physical sciencesInteraction strengthnucl-exMass spectrometry01 natural sciences7. Clean energyarseeniIonNuclear Theory (nucl-th)Nuclear physicsFragmentation (mass spectrometry)0103 physical sciencesddc:530NeutronbromiNuclear Experiment (nucl-ex)010306 general physicsNuclear ExperimentPhysicsIsotope010308 nuclear & particles physicsMass measurementAtomic massseleeniydinfysiikkaPhysical Review C
researchProduct

The determination of antimony and arsenic concentrations in fly ash by hydride generation inductively coupled plasma optical emission spectrometry (H…

2011

Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) was used in the determination of As and Sb concentrations in fly ash samples. The effect of sample pre-treatment reagents and measurement parameters used for hydride generation was evaluated. Due to memory effects observed, the appropriate read delay time was adjusted to 60 s resulting in RSDs 0.6% and 2.3% for As and Sb, respectively. The most suitable volumes of pre-reduction reagents for 10 mL of sample were 4 mL of KI/ascorbic acid (5%) and 6 mL of HCl (conc.). The determination of Sb was significantly interfered by HF, but the interference could be eliminated by adding 2 mL of saturated boric acid …

fly ashhydride generationantimonyantimoniarsenicICP-OESlentotuhkahydridin muodostusarseeni
researchProduct

Control of matrix interferences by multiple linear regression models in the determination of arsenic and lead concentrations in fly ashes by inductiv…

2010

A multiple linear regression technique was used to evaluate and correct the matrix interferences in the determination of As and Pb concentrations in fly ashes by inductively coupled plasma optical emission spectrometry. The direct determination of As and Pb in SRM 1633b by ICP-OES failed to obtain the certified concentrations, except in a couple of cases. However, it proved possible to use the multiple linear regression (MLR) technique to correct the determined concentrations to a satisfactory level. This method of correction is based on the multiple regression line obtained from the analysis of 19 synthetic mixtures of matrix and analyte elements (Al, As, Ca, Fe, Pb, and Si) at five concen…

fly ashtuhkamääritysICP-OESlyijyarseenidetermination of As and Pb
researchProduct