Search results for "arthroplasty"
showing 10 items of 163 documents
Balance Training With a Dynamometric Platform Following Total Knee Replacement: A Randomized Controlled Trial.
2018
Background and Purpose: Sensorimotor training has proven to be an efficient approach for recovering balance control following total knee replacement (TKR). The purpose of this trial was to evaluate the influence of specific balance-targeted training using a dynamometric platform on the overall state of balance in older adults undergoing TKR. Methods: This was a randomized controlled clinical trial conducted at a university hospital rehabilitation unit. Patients meeting the inclusion criteria were randomly assigned to a control group or an experimental group. Both groups participated in the same 4-week postoperative rehabilitation training protocol. Participants in the experimental group per…
Improve hip fracture outcome in the elderly patient (iHOPE) : A study protocol for a pragmatic, multicentre randomised controlled trial to test the e…
2018
IntroductionHip fracture surgery is associated with high in-hospital and 30-day mortality rates and serious adverse patient outcomes. Evidence from randomised controlled trials regarding effectiveness of spinal versus general anaesthesia on patient-centred outcomes after hip fracture surgery is sparse.Methods and analysisThe iHOPE study is a pragmatic national, multicentre, randomised controlled, open-label clinical trial with a two-arm parallel group design. In total, 1032 patients with hip fracture (>65 years) will be randomised in an intended 1:1 allocation ratio to receive spinal anaesthesia (n=516) or general anaesthesia (n=516). Outcome assessment will occur in a blinded manner aft…
Validity and reproducibility of the Physical Activity Scale for the Elderly (PASE) questionnaire for the measurement of the physical activity level i…
2014
Background The need for valid and reproducible questionnaires to routinely assess the physical activity level of patients after total knee arthroplasty (TKA) is of particular concern in clinical settings. Aims of this study were to evaluate the validity and reproducibility of the physical activity scale for the elderly (PASE) questionnaire in TKA patients, with a particular view on gender differences. Methods A total of 50 elderly patients (25 women and 25 men aged 70 ± 6 years) following primary unilateral TKA were recruited. The reproducibility was evaluated by administering the PASE questionnaire during two occasions separated by 7 days. The construct (criterion) validity was investigate…
Pain monitoring and management in a rehabilitation setting after total joint replacement
2018
Abstract Total hip replacement (THR) and, particularly, total knee replacement (TKR), are painful surgical procedures. Effective postoperative pain management leads to a better and earlier functional recovery and prevents chronic pain. Studies on the control of pain during the postoperative rehabilitation period are not common. The aim of this study is to present results of a perioperative anesthetic protocol, and a pain treatment protocol in use in the Orthopaedic and the Rehabilitation intensive units of our Hospital. 100 patients (50 THR and 50 TKR) were retrospectively included in this observational study. Numeric Rating Scale (NRS) for pain at rest registered in the clinical sheet was …
In-home versus hospital preoperative balance and proprioceptive training in patients undergoing TKR; rationale, design, and method of a randomized co…
2017
Abstract Background Severe knee osteoarthritis, as well as the surgical procedure of total knee replacement that aims to reduce its symptoms, cause great deterioration on the proprioceptive system. Taking this fact into account, and considering that balance abilities positively influence the capacity to perform basic functional tasks, this trial aims to find the short and mid-term effects of a preoperative balance and proprioceptive training when conducted by patients undergoing total knee replacement. Along with the effects, it is intended to determine whether in-home based training can be as effective as hospital training. The results will help to conclude whether the possible benefits ma…
Reduced-dose computed tomography is the most accurate method to measure ceramic hip resurfacing cup version
2020
Background: A precise assessment of cup version after hip resurfacing is generally requested, especially in clinical trials or in case of complications. Aims: To identify which diagnostic imaging modality, between AP pelvis X-rays, the AP Pelvis CT Scout image and reduced-dose axial CT scan, is the most precise to assess cup version of an all-ceramic hip resurfacing implant in a first-in-human clinical trial. Methods: We retrospectively assessed the cup version of the first 20 patients who underwent an experimental all-ceramic hip resurfacing on AP pelvis X-rays (0.8 mSv of radiation), AP pelvis CT scout images (0.016 mSv) and axial CT slices performed using a reduced dose protocol (0.3 mSv…
Factors associated with the orthopaedic surgeon's decision to recommend total joint replacement in hip and knee osteoarthritis: an international cros…
2018
Summary Objective To determine factors associated with orthopaedic surgeons' decision to recommend total joint replacement (TJR) in people with knee and hip osteoarthritis (OA). Design Cross-sectional study in eleven countries. For consecutive outpatients with definite hip or knee OA consulting an orthopaedic surgeon, the surgeon's indication of TJR was collected, as well as patients' characteristics including comorbidities and social situation, OA symptom duration, pain, stiffness and function (Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC]), joint-specific quality of life, Osteoarthritis Research Society International (OARSI) joint space narrowing (JSN) radiographi…
Preserving the abductor mechanism in robotic THR: the influence of stem design and cutterpath.
2004
The tip of the greater trochanter is the attachment site for the abductor muscles of the hip joint. Its preservation in robotic and conventional THR is important for normal gait. The effect of different stem designs and robotic cutterpaths on the preservation of the trochanter tip is examined.One anatomical stem, one straight stem, and one stem specifically designed for robotic THR were implanted virtually in CT scans of osteoarthrotic hip joints using the Torch preoperative planning unit (URS-ortho). In transverse sections of the trochanter tip, dimensions of the trochanter area removed by the milling tool were recorded for each stem design and different cutterpaths (3-axis versus 5-axis m…
Test–retest reliability and responsiveness of centre of pressure measurements in patients with hip osteoarthritis
2015
International audience; Objective: The aim of this study was to determine a set of measures for the evaluation of balance in patients suffering from hip osteoarthritis (OA) that were both reliable and responsive to change.Design: Three groups of subjects; Healthy, hip OA patients without surgery, and hip OA with surgery (pre and post-surgery) were included in this study. Subjects had to perform balance tests in two positions: standard and narrowed stance. CoP-based measures test-retest reliability was assessed in hip OA without surgery group, responsiveness were assessed between all groups and between pre and postsurgery.Results: Intraclass Correlation Coefficient (ICC) values from hip OA w…
Test-retest reliability of 3D kinematic gait variables in hip osteoarthritis patients
2011
Import JabRef | WosArea Orthopedics; Rheumatology; International audience; Objectives: (1) to investigate the test-retest reliability of 3D gait analysis (3DGA) in hip Osteoarthritis (OA) patients; (2) to find the minimum number of gait trials needed to overcome intrinsic variability; (3) to check the accuracy of angles measured by the 3D system. Design: 23 Patients suffering from hip OA with no other major disease were recruited. We evaluated the reliability of spatio-temporal variables and body angles (lower-limb joints, trunk and pelvis angles) during two sessions of 3DGA using intra-class correlation coefficients (ICC). The minimum number of trials needed to overcome intrinsic variabili…