Search results for "attenuated total reflection"
showing 10 items of 67 documents
Determination of the energetic value of fruit and milk-based beverages through partial-least-squares attenuated total reflectance-Fourier transform i…
2005
Abstract The estimation of important nutritional parameters, such as carbohydrates content and energetic value (calories) in commercially available fruit juice and flavour milk shakes has been made by attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) using a partial-least-square (PLS) calibration approach. A highly heterogeneous population of 65 samples obtained from the Spanish market, covering fruit juices, flavour milk shakes and milk-added fruit juices was used. The spectral range and the size of the calibration set for building the PLS model have been evaluated. Considering a calibration set comprised of 27 samples, selected via hierarchical cluster analys…
Estuarine sediment quality assessment by Fourier-transform infrared spectroscopy
2010
Partial least squares Fourier-transform infrared (PLS-FTIR) models were developed for the quality assessment of estuarine sediments through the evaluation of several physico-chemical parameters. Models were based on the chemometric treatment of attenuated total reflection (ATR) spectra directly obtained from samples previously lyophilized and sieved through a lower than 63 μm grid. Spectra were scanned from 3997 to 523 cm-1, averaging 36 scans per spectrum with a nominal resolution of 8 cm-1. Models were built using reference data obtained for sediment samples collected from Ria de Arousa estuary. Hierarchical cluster classification of sediment ATR spectra was employed for the establishment…
Proton Transfer and Protein Conformation Dynamics in Photosensitive Proteins by Time-resolved Step-scan Fourier-transform Infrared Spectroscopy
2014
Monitoring the dynamics of protonation and protein backbone conformation changes during the function of a protein is an essential step towards understanding its mechanism. Protonation and conformational changes affect the vibration pattern of amino acid side chains and of the peptide bond, respectively, both of which can be probed by infrared (IR) difference spectroscopy. For proteins whose function can be repetitively and reproducibly triggered by light, it is possible to obtain infrared difference spectra with (sub)microsecond resolution over a broad spectral range using the step-scan Fourier transform infrared technique. With -10(2)-10(3) repetitions of the photoreaction, the minimum num…
Determination of lidocaine in urine at low ppm levels using dispersive microextraction and attenuated total reflectance–Fourier transform infrared me…
2015
Abstract IR spectra provide valuable information about biological systems and can be obtained with compactable and affordable instruments, but the lack of sensitivity of this technique hampers its use in the determination of drugs in clinical fluids. Taking lidocaine as a target molecule, in this paper we introduced a methodology for determining drugs in urine samples using infrared spectroscopy. The lack of sensitivity of the IR was compensated with the combination of an effective and straightforward dispersive liquid–liquid microextraction and the measurement of the dry film of the organic extracts through attenuated total reflectance (ATR). The method developed improves the sensitivity b…
Nanocomposites of bacterial cellulose/hydroxyapatite for biomedical applications.
2008
In the present work, a nanocomposite material formed by bacterial cellulose (BC) networks and calcium-deficient hydroxyapatite (HAp) powders was synthesized and characterized. The HAp nanoparticles were previously prepared by a wet chemical precipitation method, starting from aqueous solutions of calcium nitrate and di-ammonium phosphate salts. Energy-dispersive spectroscopy reveals that the prepared HAp corresponds to calcium-deficient hydroxyapatite. BC-HAp nanocomposites were prepared by introducing carboxymethylcellulose (CMC) into the bacteria culture media. HAp nanoparticles were then introduced and remained suspended in the culture medium during the formation of cellulose nanofibrils…
Review and comparison of experimental techniques used for determination of thin film electro-optic coefficients
2015
The results of electro-optic coefficient measurements performed with three commonly applied techniques used to assess electro-optic coefficients: the Mach–Zehnder, the Teng–Man, and the attenuated total reflectance technique are reported. It is shown that the signal obtained by the Mach–Zehnder and Teng–Man techniques is strongly influenced by the multiple internal reflection and piezo- and electrostrictive thickness change effects, which in our opinion have not been addressed sufficiently in the literature. A novel approach based on using Abeles matrix formalism is implemented for the retrieval of electro-optic coefficients from experimental data. The measurement results, errors, and compa…
Prediction of organic carbon and total nitrogen contents in organic wastes and their composts by Infrared spectroscopy and partial least square regre…
2017
Middle and near infrared (MIR and NIR) were employed to determine organic carbon (OC) and total nitrogen (TN) in different soil organic amendments including wastes, composts and mixtures of composts and organic wastes. Prediction models based on partial least squares (PLS) regression from the spectra of untreated samples were built. Different spectra preprocessing strategies were adopted and the best number of latent variable was evaluated using leave-one-out cross-validation. Attenuated total reflectance (PLS-ATR-MIR) and diffuse reflectance (PLS-DR-NIR) models were built and evaluated from root mean square error of cross validation and prediction (RMSECV and RMSEP), coefficients of determ…
In situ ATR-IR studies in aqueous phase reforming of hydroxyacetone on Pt/ZrO2 and Pt/AlO(OH) catalysts: The role of aldol condensation
2018
Abstract In situ Attenuated Total Reflection Infrared (ATR-IR) spectroscopy was used to study Aqueous Phase Reforming of hydroxyacetone on Pt/AlO(OH) and Pt/ZrO2 catalysts at 230 °C/ 30 bar. Formation of strongly adsorbed aldol condensation products was observed on the surface of Pt/ZrO2 and ZrO2 in contrast to Pt/AlO(OH) and AlO(OH). Peak assignments were supported by DFT calculations of the IR spectra of the condensation products in vacuum and in the presence of water. Aldol condensation of hydroxyacetone leading to compounds with high molecular weight with unsaturated bonds was suggested as a first step in coke formation. Carbonaceous deposits on the surface of the ZrO2 support are oxyge…
On-line database of voltammetric data of immobilized particles for identifying pigments and minerals in archaeometry, conservation and restoration (E…
2016
[EN] A web-based database of voltammograms is presented for characterizing artists' pigments and corrosion products of ceramic, stone and metal objects by means of the voltammetry of immobilized particles methodology. Description of the website and the database is provided. Voltammograms are, in most cases, accompanied by scanning electron microphotographs, X-ray spectra, infrared spectra acquired in attenuated total reflectance Fourier transform infrared spectroscopy mode (ATR-FTIR) and diffuse reflectance spectra in the UV-Vis-region. For illustrating the usefulness of the database two case studies involving identification of pigments and a case study describing deterioration of an archae…
Determination at low ppm levels of dithiocarbamate residues in foodstuff by vapour phase-liquid phase microextraction-infrared spectroscopy
2010
Abstract A methodology based on the vapour phase (VP) generation of carbon disulphide from non-volatile dithiocarbamate compounds has been developed for determination of pesticide residues in foodstuff at low ppm levels. The method involves a selective reaction combined with liquid phase microextraction (LPME) and transmission infrared measurements. The use of a home made transmission cell improved the detection limits (LOD) compared to the use of attenuated total reflectance measurements by a factor of approximately 80. Using the most appropriate experimental conditions for the CS2 generation and LPME preconcentration, the precision of the methodology, expressed as the relative standard de…