Search results for "attenuation"

showing 10 items of 283 documents

"Dangerous liaisons: NAFLD and liver fibrosis increase cardiovascular risk in HIV".

2022

Objectives Non-alcoholic fatty liver disease (NAFLD) is strongly associated with cardiovascular disease in the general population. We aimed to assess the impact of NAFLD and liver fibrosis on intermediate-high cardiovascular risk in people living with HIV. Methods We included people living with HIV from three cohorts. NAFLD and significant liver fibrosis were defined using transient elastography: controlled attenuation parameter >= 288 dB/m and liver stiffness measurement >= 7.1 kPa, respectively. Cardiovascular risk was assessed with the atherosclerotic cardiovascular disease (ASCVD) risk estimator in patients aged between 40 and 75 years and categorised as low if <5%, borderline …

AdultLiver CirrhosisLiver CirrhosiHIV InfectionsBMIElasticity Imaging TechniqueNon-alcoholic Fatty Liver DiseaseRisk FactorsCardiovascular DiseaseHumansHIV InfectionPharmacology (medical)Prospective StudiesNon-alcoholic Fatty Liver Disease.AgedASCVD score; BMI; controlled attenuation parameter; HIV mono-infection; transient elastographyASCVD scoreRisk FactorHealth PolicyHIV mono-infectionHeart Disease Risk FactorMiddle Agedtransient elastographycontrolled attenuation parameterProspective StudieInfectious DiseasesLiverCardiovascular DiseasesHeart Disease Risk FactorsElasticity Imaging TechniquesHumanHIV medicineREFERENCES
researchProduct

Influence of the structural components of artificial turf systems on impact attenuation in amateur football players

2019

AbstractThe purpose of this research was to evaluate the influence of the structural components of different 3rd generation artificial turf football field systems on the biomechanical response of impact attenuation in amateur football players. A total of 12 amateur football players (24.3 ± 3.7 years, 73.5 ± 5.5 kg, 178.3 ± 4.1 cm and 13.7 ± 4.3 years of sport experience) were evaluated on three third generation artificial turf systems (ATS) with different structural components. ATS were composed of asphalt sub-base and 45 mm of fibre height with (ATS1) and without (ATS2) elastic layer or compacted granular sub-base, 60 mm of fibre height without elastic layer (ATS3). Two triaxial accelerome…

AdultMale0301 basic medicineAccelerationPoison controlSTRIDElcsh:MedicineFútbolArticleLower energyRunningYoung Adult03 medical and health sciences0302 clinical medicineFloors and FloorcoveringsSoccerArtificial turfHumanslcsh:ScienceMathematicsOrthodonticsEsportsFootball playersMultidisciplinaryAttenuationlcsh:RDeporteBone quality and biomechanicsBiomechanical Phenomena030104 developmental biologyRisk factorsAthletesFootball fieldSuperficies deportivas sintéticaslcsh:QEducació físicaAmateur030217 neurology & neurosurgeryInstalación deportiva
researchProduct

The location of the tibial accelerometer does influence impact acceleration parameters during running

2016

Tibial accelerations have been associated with a number of running injuries. However, studies attaching the tibial accelerometer on the proximal section are as numerous as those attaching the accelerometer on the distal section. This study aimed to investigate whether accelerometer location influences acceleration parameters commonly reported in running literature. To fulfil this purpose, 30 athletes ran at 2.22, 2.78 and 3.33 m · s–1 with three accelerometers attached with double-sided tape and tightened to the participants’ tolerance on the forehead, the proximal section of the tibia and the distal section of the tibia. Time-domain (peak acceleration, shock attenuation) and frequency-doma…

AdultMaleAcousticsDecelerationAccelerationPhysical Therapy Sports Therapy and RehabilitationAccelerometerSignallaw.inventionRunningTibial acceleration03 medical and health sciencesAcceleration0302 clinical medicinelawAccelerometryTEORIA DE LA SEÑAL Y COMUNICACIONESTibial accelerationHumansOrthopedics and Sports MedicineTibiaFrequency analysisLegTibiaAttenuation030229 sport sciencesGeodesyShock attenuationShock (mechanics)Biomechanical PhenomenaFrequency analysis030217 neurology & neurosurgeryGeology
researchProduct

Transmission of Vertical Whole Body Vibration to the Human Body

2008

According to experimental studies, low-amplitude high-frequency vibration is anabolic to bone tissue, whereas in clinical trials, the bone effects have varied. Given the potential of whole body vibration in bone training, this study aimed at exploring the transmission of vertical sinusoidal vibration to the human body over a wide range of applicable amplitudes (from 0.05 to 3 mm) and frequencies (from 10 to 90 Hz). Vibration-induced accelerations were assessed with skin-mounted triaxial accelerometers at the ankle, knee, hip, and lumbar spine in four males standing on a high-performance vibration platform. Peak vertical accelerations of the platform covered a range from 0.04 to 19 in units …

AdultMalePhysicsEndocrinology Diabetes and MetabolismAcousticsAttenuationPosture030209 endocrinology & metabolism030229 sport sciencesAnatomyMiddle AgedAccelerometerVibrationVibration03 medical and health sciencesHuman musculoskeletal systemAcceleration0302 clinical medicineAmplitudemedicine.anatomical_structuremedicineHumansWhole body vibrationOrthopedics and Sports MedicineAnkleJournal of Bone and Mineral Research
researchProduct

Characterization of Small Incidental Indeterminate Hypoattenuating Hepatic Lesions: Added Value of Single-Phase Contrast-Enhanced Dual-Energy CT Mate…

2018

OBJECTIVE. The objective of this study is to determine whether single-phase contrast-enhanced dual-energy CT (DECT) material attenuation analysis improves the characterization of small (< 2.0 cm) incidental indeterminate hypoattenuating hepatic lesions, compared with conventional single-energy CT evaluation. MATERIALS AND METHODS. This retrospective study involved 55 patients (24 men and 31 women; mean [± SD] age, 63.9 ± 15.3 years) with 77 incidental hypoattenuating hepatic lesions (59 benign and 18 malignant lesions) measuring 0.5–2.0 cm who underwent single-phase contrast-enhanced DECT of the abdomen for pain. For each lesion, attenuation measurements were obtained using blended 120-k…

AdultMalegenetic structuresmedia_common.quotation_subjectContrast MediaSensitivity and Specificity030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineRetrospective StudieIncidental FindingIncidentalHumansContrast (vision)MedicineRadiology Nuclear Medicine and imagingSingle phaseAgedRetrospective Studiesmedia_commonAged 80 and overIncidental FindingsEnhancementbusiness.industryLiver lesionAttenuationLiver NeoplasmsGeneral MedicineMiddle AgedIopamidolCharacterization (materials science)Dual-energy CTLiver Neoplasm030220 oncology & carcinogenesisRadiographic Image Interpretation Computer-AssistedFemaleDual energy ctTomography X-Ray ComputedIndeterminateNuclear medicinebusinessIodineHumanAmerican Journal of Roentgenology
researchProduct

A strain-difference-based nonlocal elasticity model

2004

Abstract A two-component local/nonlocal constitutive model for (macroscopically) inhomogeneous linear elastic materials (but constant internal length) is proposed, in which the stress is the sum of the local stress and a nonlocal-type stress expressed in terms of the strain difference field, hence identically vanishing in the case of uniform strain. Attention is focused upon the particular case of piecewise homogeneous material. The proposed model is thermodynamically consistent with a suitable free energy potential. It constitutes an improved form of the Vermeer and Brinkgreve [A new effective nonlocal strain measure for softening plasticity. In: Chambon, R., Desrues, J., Vardulakis, I. (E…

Applied MathematicsMechanical EngineeringAttenuationMathematical analysisConstitutive equationLinear elasticityGeometryPlasticityCondensed Matter PhysicsBifurcation theoryMechanics of MaterialsModeling and SimulationPiecewiseGeneral Materials ScienceSofteningMathematicsNumerical stabilityInternational Journal of Solids and Structures
researchProduct

Quantitative XPS analysis of leached layers on optical glasses

1993

The corrosion of optical glasses often reduces the utility of uncoated glasses as well as the adhesion of resistive coatings deposited onto corroded glasses. Photoelectron spectroscopy (XPS) was applied to study glass surfaces with respect to their surface corrosion. In particular, leaching by the influence of polish slurries, pure water, air and even residual gases inside a vacuum device was studied in detail. Pure quartz glass and different sodium and barium silicate glasses were broken in ultrahigh vacuum (4 × 10−10 mbar) for the determination of sensitivity factors of the different XPS signals. It was found that a quantitative determination of the surface composition of corroded and lea…

Aqueous solutionHydrogenAnalytical chemistryAttenuation lengthchemistry.chemical_elementMineralogyBariumSurfaces and InterfacesGeneral ChemistryCondensed Matter PhysicsSurfaces Coatings and FilmsCorrosionchemistryX-ray photoelectron spectroscopyMaterials ChemistryLeaching (metallurgy)QuartzSurface and Interface Analysis
researchProduct

Simultaneous segmentation and beam-hardening correction in computed microtomography of rock cores

2013

We propose a post-reconstruction correction procedure for the beam-hardening artifact that neither requires knowledge of the X-ray spectrum nor of the attenuation coefficients in multi-mineral geologic samples. The beam-hardening artifact in polychromatic X-ray computer tomography (CT) hampers segmentation of the phase assemblage in geologic samples. We show that in cylindrically shaped samples like rock cores, the X-ray attenuation value for a single phase depends mainly on the distance from the center of the cylinder. This relationship could be easily extracted from the CT data for every phase and used to infer the presence of these phases at all positions in the sample. Our new approach …

Artifact (error)Materials scienceAttenuationPhase (waves)MineralogyCylinderGeometrySegmentationImage segmentationTomographyComputers in Earth SciencesSample (graphics)Information SystemsComputers & Geosciences
researchProduct

Techniques for measuring aerosol attenuation using the Central Laser Facility at the Pierre Auger Observatory

2013

The Pierre Auger Observatory in Malargue, Argentina, is designed to study the properties of ultra-high energy cosmic rays with energies above 10(18) eV. It is a hybrid facility that employs a Fluorescence Detector to perform nearly calorimetric measurements of Extensive Air Shower energies. To obtain reliable calorimetric information from the FD, the atmospheric conditions at the observatory need to be continuously monitored during data acquisition. In particular, light attenuation due to aerosols is an important atmospheric correction. The aerosol concentration is highly variable, so that the aerosol attenuation needs to be evaluated hourly. We use light from the Central Laser Facility, lo…

AstronomyDetector alignment and calibration methods (lasers sources particle-beams)01 natural sciencesDetector alignment and calibration methods (laserObservatoryATMOSPHERIC CONDITIONSDetector alignment and calibration methodsInstrumentationcosmic rayMathematical PhysicsHigh Energy Astrophysical Phenomena (astro-ph.HE)Physicsatmospheric monitoring[SDU.ASTR.HE]Sciences of the Universe [physics]/Astrophysics [astro-ph]/High Energy Astrophysical Phenomena [astro-ph.HE]PhysicsData analysiparticle-beams)ComputingMethodologies_DOCUMENTANDTEXTPROCESSINGCentral Laser FacilityFísica nuclearAstrophysics - Instrumentation and Methods for AstrophysicsAstrophysics - High Energy Astrophysical Phenomenasources[PHYS.ASTR.HE]Physics [physics]/Astrophysics [astro-ph]/High Energy Astrophysical Phenomena [astro-ph.HE][PHYS.ASTR.IM]Physics [physics]/Astrophysics [astro-ph]/Instrumentation and Methods for Astrophysic [astro-ph.IM]sourceAuger Experimentaerosols * Authors are listed on the following pagesData analysisFOS: Physical sciencesCosmic rayAuger Experiment; cosmic rays; atmospheric monitoring; aerosolsOpticscosmic raysUltra-high energy cosmic rays. atmospheric monitoring. aerosols0103 physical sciences010306 general physicsInstrumentation and Methods for Astrophysics (astro-ph.IM)Pierre Auger Observatory010308 nuclear & particles physicsbusiness.industryLarge detector systems for particle and astroparticle physicsAttenuationAtmospheric correctionUltra-high energy cosmic rays[SDU.ASTR.IM]Sciences of the Universe [physics]/Astrophysics [astro-ph]/Instrumentation and Methods for Astrophysic [astro-ph.IM]AerosolDetector alignment and calibration methods (lasersAir showerdetector alignment and calibration methods (lasers; sources; particle-beams); large detector systems for particle and astroparticle physics; data analysisExperimental High Energy PhysicsLarge detector systems for particle and astroparticle physicbusinessRAIOS CÓSMICOSaerosolsSYSTEM
researchProduct

A more reliable relation between Angström and Linke atmospheric turbidity parameters

1989

Abstract This work analyses the correlation between Angstrom and Linke atmospheric turbidity parameters (β and T ) which are commonly used in studies about the atmosphere's behaviour since they efficaciously monitor a point turbidity state and model the aerosol attenuation of solar radiation. Starting from the usual linear relation β = a + bT , a more reliable one is here derived by hourly data of three coastal locations with typical Mediterranean meteoclimatic characteristics, for values of the experimental ratios of diffuse and global solar radiation ⩽0.3. The expression found notably differs from the starting one as shown by the time variable.

AtmosphereMeteorologyAttenuationGeneral EngineeringLinear relationEnvironmental scienceAngstromTurbidityRadiationAtmospheric sciencesTurbiditeAerosolSolar & Wind Technology
researchProduct