Search results for "axial"

showing 10 items of 457 documents

Stability of the upper neck during isometric neck exercises in rheumatoid arthritis patients with atlantoaxial disorders.

2008

To study the effect of isometric neck strength exercises on upper cervical stability in patients with rheumatoid arthritis (RA).Twenty patients with a mean (SD) age of 58 (9) years and duration of RA of 27 (10) years volunteered for the study. Lateral radiographs of the cervical spine were taken to measure the current atlantoaxial distance (AAD) in flexion and extension. Maximal isometric neck flexion and extension strength values were measured by a dynamometer. Thereafter, AADs were measured from radiographs taken at 80-90% resistance of maximal strength.According to the full flexion radiographs at baseline, the patients were classified into three groups: eight patients without anterior at…

AdultJoint InstabilityMalemedicine.medical_specialtyRadiographyImmunologyPhysical exerciseIsometric exerciseArthritis RheumatoidRheumatologyNeck MusclesInternal medicinemedicineImmunology and AllergyHumansIn patientRange of Motion ArticularExerciseAgedbusiness.industryGeneral MedicineNeck exercisesAtlantoaxial subluxationMiddle Agedmedicine.diseaseRheumatologySurgeryBiomechanical PhenomenaExercise TherapyRadiographyCross-Sectional StudiesAtlanto-Axial JointRheumatoid arthritisFemalebusinessNeckScandinavian journal of rheumatology
researchProduct

Repeatability assessment of biometric measurements with different refractive states and age using a swept-source biometer

2018

Background We aim to assess if refractive error or age may influence the repeatability of measurements using a swept-source biometer. Methods A total of 61 subjects were evaluated with IOLMaster 700 acquiring measurements of axial length (AL), central corneal thickness (CCT), white-to-white distance (WTW), anterior aqueous depth (AQD), lens thickness (LT), and keratometry (K) readings. Repeatability was evaluated classifying the sample according to the refractive state and age by the calculation of the within-subject standard deviation (Sw), coefficient of repeatability, and intraclass correlation coefficient. Results Very similar Sw was acquired among groups for AL, CCT, and WTW. Differenc…

AdultMaleAgingRefractive errormedicine.medical_specialtyBiometryIntraclass correlationBiomedical Engineering030204 cardiovascular system & hematologyAstigmatismStandard deviationlaw.inventionYoung Adult03 medical and health sciences0302 clinical medicineLens thicknessAge groupslawOphthalmologyLens CrystallinemedicineHumansMathematicsKeratometerAge FactorsReproducibility of ResultsGeneral MedicineRepeatabilityMiddle AgedRefractive Errorsmedicine.diseaseAxial Length EyeFemaleSurgeryTomography Optical Coherence030217 neurology & neurosurgeryExpert Review of Medical Devices
researchProduct

Association of Low Birth Weight With Altered Corneal Geometry and Axial Length in Adulthood in the German Gutenberg Health Study

2019

IMPORTANCE: Low birth weight is associated with altered ocular organ development in childhood, including the morphology of the eye. However, no population-based data exist about this association in adulthood. OBJECTIVE: To evaluate whether low birth weight has a long-term association with anterior segment anatomy and axial length in adulthood. DESIGN, SETTING, AND PARTICIPANTS: The Gutenberg Health Study is a population-based, observational cohort study in Germany. All participants underwent ocular biometry. Among the participants with follow-up and self-reported birth weight available, associations were assessed between low birth weight and anterior segment anatomy and axial length using m…

AdultMaleBirth weightPopulationGeometry01 natural sciencesCohort StudiesCornea03 medical and health sciences0302 clinical medicineCorneaGermanymedicineHumansIn patient0101 mathematicseducationOriginal InvestigationAgedAged 80 and overeducation.field_of_studybusiness.industry010102 general mathematicsInfant NewbornRetinopathy of prematurityAxial lengthInfant Low Birth WeightMiddle Agedmedicine.diseaseOphthalmologyLow birth weightAxial Length Eyemedicine.anatomical_structure030221 ophthalmology & optometryFemalemedicine.symptombusinessCohort study
researchProduct

Using Accelerometry for Evaluating Energy Consumption and Running Intensity Distribution Throughout a Marathon According to Sex

2020

The proportion of females participating in long-distance races has been increasing in the last years. Although it is well-known that there are differences in how females and males face a marathon, higher research may be done to fully understand the intrinsic and extrinsic factors affecting sex differences in endurance performance. In this work, we used triaxial accelerometer devices to monitor 74 males and 14 females, aged 30 to 45 years, who finished the Valencia Marathon in 2016. Moreover, marathon split times were provided by organizers. Several physiological traits and training habits were collected from each participant. Then, we evaluated several accelerometry- and pace-estimated para…

AdultMaleHealth Toxicology and Mutagenesiseducationphysical activitylcsh:MedicineAthletic PerformanceAccelerometerArticleRunning03 medical and health sciences0302 clinical medicineHeart RateKilometerenergy consumptionaccelerometryHumanssexpacingTriaxial accelerometerWork (physics)lcsh:RPublic Health Environmental and Occupational Health030229 sport sciencesEnergy consumptionMiddle AgedLipid MetabolismOxygen uptakeIntensity (physics)running intensityAthletesPhysical EnduranceRunning economymarathonersrunning economyFemaleEnergy MetabolismPsychologyhuman activities030217 neurology & neurosurgeryDemographyInternational Journal of Environmental Research and Public Health
researchProduct

Biaxial Microincision versus Coaxial Small-Incision Clear Cornea Cataract Surgery

2005

Objective To compare clinical outcomes of biaxial microincision (1.5 mm) and coaxial small-incision (2.75 mm) clear cornea cataract surgery. Design Randomized controlled clinical trial. Participants Seventy eyes of 70 patients were examined at a German university eye hospital. Intervention The 70 patients (70 eyes) were assigned randomly (1:1) to a biaxial or conventional coaxial incision group. Both groups underwent phacoemulsification using pulsed ultrasound energy with variable duty cycles, followed by microincision intraocular lens implantation. Main Outcome Measures Best-corrected visual acuity (BCVA), astigmatism, laser flare photometry value, effective phacoemulsification time (EPT),…

AdultMaleMicrosurgerymedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityCell CountIntraocular lensAstigmatismCorneaLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesDioptreAgedAged 80 and overPhacoemulsificationbusiness.industryEndothelium CornealAstigmatismPhacoemulsificationMiddle AgedCataract surgerymedicine.diseaseOphthalmologyFemalemedicine.symptomCoaxialbusinessSurgical incisionOphthalmology
researchProduct

Optical coherence tomography of macular thickness after biaxial vs coaxial microincision clear corneal cataract surgery

2009

PURPOSE To evaluate macular thickness changes after biaxial microincision versus coaxial small incision cataract surgery using optical coherence tomography (OCT). METHODS This prospective, randomized, marked study comprised 70 patients (70 eyes) undergoing biaxial microincision surgery or conventional coaxial phacoemulsification. Patients were evaluated by Stratus OCT preoperatively and 1 day, 4 weeks, and 8 weeks postoperatively. Best-corrected visual acuity (BCVA), phacoemulsification power, and effective phacoemulsification time (EPT) were evaluated. RESULTS In the biaxial group, median foveal thickness changed from 160 microm preoperatively to 168 microm 8 weeks postoperatively (p=0.018…

AdultMaleMicrosurgerymedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityFoveal thicknessMacular EdemaCornea03 medical and health sciencesPostoperative Complications0302 clinical medicineOptical coherence tomographyOphthalmologyBlood-Retinal BarrierHumansMedicineMacula LuteaProspective StudiesIntraoperative ComplicationsAgedAged 80 and overPhacoemulsificationmedicine.diagnostic_testbusiness.industrySignificant differenceGeneral MedicinePhacoemulsificationMiddle AgedCataract surgeryeye diseasesOphthalmologySmall incision030221 ophthalmology & optometryFemalesense organsmedicine.symptomCoaxialbusinessTomography Optical Coherence030217 neurology & neurosurgeryEuropean Journal of Ophthalmology
researchProduct

Nine Loci for Ocular Axial Length Identified through Genome-wide Association Studies, Including Shared Loci with Refractive Error

2013

Refractive errors are common eye disorders of public health importance worldwide. Ocular axial length (AL) is the major determinant of refraction and thus of myopia and hyperopia. We conducted a meta-analysis of genome-wide association studies for AL, combining 12,531 Europeans and 8,216 Asians. We identified eight genome-wide significant loci for AL (RSPO1, C3orf26, LAMA2, GJD2, ZNRF3, CD55, MIP, and ALPPL2) and confirmed one previously reported AL locus (ZC3H11B). Of the nine loci, five (LAMA2, GJD2, CD55, ALPPL2, and ZC3H11B) were associated with refraction in 18 independent cohorts (n = 23,591). Differential gene expression was observed for these loci in minus-lens-induced myopia mouse …

AdultMaleRefractive errorAdolescentGene ExpressionLocus (genetics)Genome-wide association studyBiologyOcular Axial LengthPolymorphism Single NucleotideWhite PeopleArticle03 medical and health sciences0302 clinical medicineAsian PeopleSDG 3 - Good Health and Well-beingmedicineGeneticsHumansGWASGenetic Predisposition to DiseaseGenetics(clinical)RSPO1Eye ProteinsGeneGenetics (clinical)030304 developmental biologyGenetic associationAgedGenetics0303 health sciencesta1184HeritabilityMiddle Agedta3121medicine.diseaseRefractive ErrorsAxial Length EyeGenetic Loci030221 ophthalmology & optometryEye disorderFemaleGenome-Wide Association StudySignal Transduction
researchProduct

Establishing cut-points for physical activity classification using triaxial accelerometer in middle-aged recreational marathoners

2018

The purpose of this study was to establish GENEA (Gravity Estimator of Normal Everyday Activity) cut-points for discriminating between six relative-intensity activity levels in middle-aged recreational marathoners. Nighty-eight (83 males and 15 females) recreational marathoners, aged 30-45 years, completed a cardiopulmonary exercise test running on a treadmill while wearing a GENEA accelerometer on their non-dominant wrist. The breath-by-breath V̇O2 data was also collected for criterion measure of physical activity categories (sedentary, light, moderate, vigorous, very vigorous and extremely vigorous). GENEA cut-points for physical activity classification was performed via Receiver Operatin…

AdultMaleSupport Vector MachinePhysical activitylcsh:Medicine030204 cardiovascular system & hematologyAccelerometerRunning03 medical and health sciences0302 clinical medicineSex FactorsCardiopulmonary exercise testStatisticsGeneaAccelerometryMedicineHumansCorrelation testTreadmilllcsh:ScienceMultidisciplinarybiologyReceiver operating characteristicbusiness.industryTriaxial accelerometerlcsh:R030229 sport sciencesMiddle Agedbiology.organism_classificationROC CurveArea Under CurveExercise TestFemalelcsh:QbusinessEnergy Metabolism
researchProduct

T2 Mapping of the Sacroiliac Joints in Patients with Axial Spondyloarthritis

2020

Purpose: To test whether T2 mapping of the sacro-iliac joints (SIJs) might help identifying patients with spondyloarthritis. Method: This study included 20 biologic-naive patients with axial spondyloarthritis (10 females; mean age: 38 ± 9years; range, 19–47) and 27 controls (16 males; mean age = 39 ± 13years; range = 28–71) who prospectively underwent SIJs MRI at 1.5 T, including a multislice multiecho spin-echo sequence. Standard MRIs were reviewed to assess the SIJs according to the Assessment of SpondyloArthritis International Society (ASAS) criteria and SPondyloArthritis Research Consortium of Canada (SPARCC) MRI index. T2 maps obtained from multiecho sequences were used to draw regions…

AdultMaleT2 mappingSacroiliac joint030218 nuclear medicine & medical imagingYoung Adult03 medical and health sciences0302 clinical medicineMagnetic resonance imagingSpondylarthritisChi-square testHumansMedicineRadiology Nuclear Medicine and imagingIn patientMultisliceProspective StudiesSacroiliitisAxial spondyloarthritisBASDAISacroiliitis.Observer Variationbusiness.industrySacroiliitisCurve analysisReproducibility of ResultsGeneral MedicineMiddle Agedmedicine.diseaseCross-Sectional StudiesCartilageCase-Control Studies030220 oncology & carcinogenesisFemalebusinessNuclear medicine
researchProduct

Comparison of Immersion Ultrasound, Partial Coherence Interferometry, and Low Coherence Reflectometry for Ocular Biometry in Cataract Patients

2011

PURPOSE: To compare ocular biometry parameters measured with immersion ultrasound, partial coherence interferometry, and low coherence reflectometry in cataract patients. METHODS: Measurements of axial length and anterior chamber depth were analyzed and compared using immersion ultrasound, partial coherence interferometry, and low coherence reflectometry. Keratometry (K), flattest axis, and white-to-white measurements were compared between partial coherence interferometry and low coherence reflectometry. Seventy-eight cataract (LOCS II range: 1 to 3) eyes of 45 patients aged between 42 and 90 years were evaluated. A subanalysis as a function of cataract degree was done for axial length and…

AdultMalemedicine.medical_specialtyBiometryMaterials scienceAnterior ChamberDiagnostic Techniques OphthalmologicalCataractlaw.inventionOpticslawOphthalmologymedicineHumansBody Weights and MeasuresReflectometryAgedUltrasonographyAged 80 and overKeratometerbusiness.industryUltrasoundAnova testAxial lengthMiddle AgedAxial Length EyeOphthalmologyInterferometryInterferometryPartial coherence interferometryFemaleSurgeryUltrasonographybusinessJournal of Refractive Surgery
researchProduct