Search results for "binocular"
showing 10 items of 89 documents
Symmetric bilateral implantation of a distance-dominant diffractive bifocal intraocular lens
2007
To assess visual results after symmetrical bilateral implantation of a distance-dominant bifocal diffractive intraocular lens (IOL).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Fifty patients had bilateral implantation of a distance-dominant diffractive bifocal 447D IOL (Acri.Tec GmbH) in a prospective study. Monocular and binocular best corrected distance visual acuities and best distance-corrected near visual acuity, binocular best distance-corrected intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were determined.At the 6-month postoperative visit, the mean binocular best corrected distance acuity and…
Long-term follow-up of a multifocal apodized diffractive intraocular lens after cataract surgery.
2007
Purpose To report the long-term performance of the AcrySof ReSTOR SA60D3 intraocular lens (IOL) after cataract surgery. Setting University Hospital Maastricht, Maastricht, The Netherlands. Methods This prospective clinical trial comprised 44 eyes (22 consecutive patients) having cataract surgery with implantation of the ReSTOR IOL. Monocular and binocular uncorrected distance visual acuity, best corrected distance visual acuity, uncorrected near visual acuity, best distance-corrected near visual acuity, spectacle dependence, undesired visual symptoms, patient satisfaction, and incidence of posterior capsule opacification were analyzed 6 months and 3 years postoperatively. Results The mean u…
Relation between fixation disparity and the asymmetry between convergent and divergent disparity step responses
2007
Abstract The neural network model of Patel et al. [Patel, S. S., Jiang, B. C., & Ogmen, H. (2001). Vergence dynamics predict fixation disparity. Neural Computation, 13 (7), 1495–1525] predicts that fixation disparity, the vergence error for a stationary fusion stimulus, is the result of asymmetrical dynamic properties of disparity vergence mechanisms: faster (slower) convergent than divergent responses give rise to an eso (exo) fixation disparity, i.e., over-convergence (under-convergence) in stationary fixation. This hypothesis was tested in the present study with an inter-individual approach: in 16 subjects we estimated the vergence step response to a 1 deg disparity stimulus with a subje…
Monocular versus binocular pupillometry.
2004
Purpose To quantify differences between monocular and binocular pupil size measurement under scotopic and mesopic conditions. Setting Department of Ophthalmology, Johannes Gutenberg-University, and Department of Medical Biometry, Epidemiology and Informatics, University of Mainz, Mainz, Germany. Methods Computerized dynamic pupillometry (P2000 SA, Procyon Instruments Ltd.) was used at 3 illumination levels: scotopic at 0.03 lux, mesopic low at 0.82 lux, and mesopic high at 6.4 lux. One hundred forty eyes of 70 healthy volunteers without ocular pathology were examined. The subjects were divided into 2 groups. In the first group, the pupil diameter was measured binocularly first. In the secon…
Prevalence of general binocular dysfunctions in a population of university students.
1997
Although some authors report that the prevalence of general binocular dysfunctions (nonstrabismic) for nonpresbyopes in the clinical population is greater than any condition except refractive error, limited research is available to support this statement. This clinical study determined the presence and clinical implications of these conditions in a population of university students with heavy near visual demands.From a group of second year students who were given a thorough eye examination, 65 students were selected. The criteria for selection were the absence of significant uncorrected refractive error, healthy eyes, and no strabismus or amblyopia.32.3% of the subjects showed general binoc…
2014
The face inversion effect is regarded as a hallmark of face-specific processing, and can be observed in a large variety of visual tasks. Face inversion effects are also reported in binocular rivalry. However, it is unclear whether these effects are face-specific, and distinct from the general tendency of visual awareness to privilege upright objects. We studied continuous rivalry across more than six hundred dominance epochs for each observer, having faces and houses rival against their inverted counterparts, and letting faces rival against houses in both upright and inverted orientation. We found strong inversion effects for faces and houses in both the frequency of dominance epochs and th…
2017
In continuous flash suppression (CFS), a dynamic noise masker, presented to one eye, suppresses conscious perception of a test stimulus, presented to the other eye, until the suppressed stimulus comes to awareness after few seconds. But what do we see breaking the dominance of the masker in the transition period? We addressed this question with a dual-task in which observers indicated (i) whether the test object was left or right of the fixation mark (localization) and (ii) whether it was a face or a house (categorization). As done recently (Stein et al., 2011), we used two experimental varieties to rule out confounds with decisional strategy. In the terminated mode, stimulus and masker wer…
Stereopsis assessment at multiple distances with an iPad application
2017
[EN] We present a new application for iPad for screening stereopsis at multiple distances that allows testing up to ten levels of stereoacuity at each distance. Our approach is based on a random dot stereogram viewable with anaglyph spectacles. Sixty-five subjects with no ocular diseases, wearing their habitual correction were measured at 3 m and 0.5 m. Results were compared with a standard stereoscopic test (TNO). We found not statistically significant differences between both tests, but our method achieved higher reproducibility. Applications in visual screening programs and to design and use of 3D displays, are suggested. (C) 2017 Elsevier B.V. All rights reserved.
Are simple striate cells analysers of visual signals both in spatial position as well as in spatial frequency?
1984
According to a modern view, simple cells of the cat striate cortex are considered to operate as apart of Fourier analysis system thus leading to the idea that the operational mechanism of the visual cortex is concerned with the analysis of spatial frequencies. Nevertheless if simple cells are really concerned only with the analysis of spatial frequencies there should exist a strict relationship between their spatial frequency selectivity and the spatial organization of their receptive fields. This is because it is the spatial organization of the spatial frequency detector i.e. the cell's receptive field that determines the cell's spatial frequency selectivity. Since the quantitative analysi…
Guest Editorial Three-Dimensional Displays and Visualization
2010
THREE-DIMENSIONAL (3D) imaging and display is a natural concept for humans as it is a common vision attribute of our binocular vision, perception, and brain processing. However, until recently, our experiences have been mainly limited to the technologically inferior two-dimensional (2D) as evidenced from widespread use of 2D photography, cinema, and liquid crystal or LED-display for television, computer displays, etc.