Search results for "blee"
showing 10 items of 263 documents
Experimental characterization of bodycentric passive RFID systems
2011
Recent progresses in the design of wearable RFID tag antennas stimulate the idea of passive bodycentric systems wherein the required power to drive the wearable tags is directly scavenged from the interrogation signal emitted by the reader unit. While active bodycentric links have been extensively investigated, the feasibility of passive systems is still questionable due to the poor sensitivity of the tags and to the modest read distances. This paper describes an articulated measurement campaign with textile wearable low-profile tags in the UHF RFID band. It is demonstrated that both on-body and off-body links are feasible with a power budget fully compliant with the available technology. T…
Ileo-ileal invagination--a cause of recurrent mid-gastrointestinal bleeding: diagnostic and endoscopic therapy by means of push-and-pull enteroscopy.
2008
The types of lesions that cause bleeding in the small bowel are similar to those found in other areas in the gastrointestinal tract, such as vascular malformations, ulcers and inflammatory lesions, neoplasms and other less common lesions like Meckel's diverticulum. This report describes three patients with suspected mid-gastrointestinal bleeding with no significant past medical history. Before presenting to our unit the diagnostic work-up such as oesophagogastroduodenoscopy, colonoscopy and radiological small bowel imaging such as conventional enteroclysis or magnet resonance imaging enteroclysis had been performed without detecting any bleeding source. Capsule endoscopy suspected an angiod…
Transvalvular enteroscopy using a mother-baby endoscope system: a new approach to the distal ileum.
1997
In the past decade various endoscopes have been developed to examine the small bowel, with two principal procedures established: sonde-type enteroscopy and push-type enteroscopy. The main indication is gastrointestinal bleeding of obscure origin. Push-type enteroscopy has proved itselfto be useful for the investigation ofdiseases of the small intestine. 1 The mean instrumental insertion length published by different working groups varied between 50 and 90 cm past the ligament of Trei tzfl 2 The small bowel examination area is limited to the jejunum. The alternative method is sonde-type enteroscopy that allows an insertion length of 140 (30 to 200) cm. 3, 4 Disadvantages of this type of ente…
ag) Push-and-pull enteroscopy in the small bowel using the double-balloon technique: results of a prospective European multicenter study.
2005
BACKGROUND AND STUDY AIMS The aim of this study was to evaluate the feasibility, safety, and clinical impact of push-and-pull enteroscopy (PPE) in patients with suspected or documented small-bowel diseases, in a prospective multicenter trial in three European medical centers. PATIENTS AND METHODS A total of 100 patients (mean age 56 +/- 16 years; range 13 - 90) were included at the three institutions between July and November 2004. The leading symptoms were: acute recurrent or chronic gastrointestinal bleeding (n = 64), polyposis syndrome (n = 8), chronic abdominal pain (n = 7), chronic diarrhea (n = 7), and others (n = 14). RESULTS No major PPE-associated complications such as perforation,…
Double-balloon enteroscopy-facilitated cyanoacrylate-injection endotherapy of small-bowel varices: an international experience from 2 European tertia…
2019
Background and Aims Small-bowel varices (SBVs) are an uncommon consequence of portal hypertension. Radiologic intervention is usually considered for first-line management. When radiologic intervention is not possible, management options become very limited. The aim of this study was to evaluate the usefulness of double-balloon enteroscopy (DBE)-facilitated cyanoacrylate-injection endotherapy of SBVs. Methods This was a retrospective review of DBE-facilitated cyanoacrylate-injection endotherapy of SBVs (December 2015 to October 2016). Results Ten DBEs were performed in 6 patients (4 women; median age, 68.5 years). No radiologic or surgical options were deemed feasible. Thirteen nests of SBVs…
Long-term outcome after argon plasma coagulation of small-bowel lesions using double-balloon enteroscopy in patients with mid-gastrointestinal bleedi…
2011
BACKGROUND AND STUDY AIMS Vascular malformations are the most common sources of bleeding in the small bowel. They can be treated with argon plasma coagulation (APC) during double-balloon enteroscopy (DBE). This study aimed to evaluate the long-term follow-up of the effectiveness of APC for small-bowel bleeding by means of a single-center retrospective study. PATIENTS AND METHODS Between June 2003 and December 2005, APC treatment for small-bowel lesions was carried out during DBE in 63 patients with known or suspected mid-gastrointestinal bleeding. Fifty patients were included in the analysis. Main outcome measurements were comparison of hemoglobin values and blood transfusion requirements b…
Mid-gastrointestinal bleeding: capsule endoscopy and push-and-pull enteroscopy give rise to a new medical term.
2006
Clinical efficacy of highly purified, doubly virus-inactivated factor VIII/von Willebrand factor concentrate (Fanhdi® ) in the treatment of von Wille…
2002
Summary. The goal of therapy in patients with von Willebrand disease (vWD) is to correct the dual defect of primary haemostasis and intrinsic coagulation reflected by low levels of von Willebrand factor (vWF) and factor VIII coagulant activity (FVIII:C). Factor VIII/von Willebrand factor (FVIII/vWF) concentrates are currently the treatment of choice in vWD patients unresponsive to desmopressin (DDAVP). However, only few studies on their clinical use are available so far. The main objective of this study was to retrospectively evaluate the clinical efficacy of a highly purified, doubly virus-inactivated FVIII/vWF concentrate with a high content of FVIII/vWF (Fanhdi®). Twenty-two patients wit…
Recombinant, activated factor VII for surgery in factor VII deficiency: a prospective evaluation - the surgical STER
2010
Excessive bleeding represents a major complication of surgical interventions and its control is especially relevant in patients with Congenital Bleeding Disorders (CBD). In factor VII (FVII) deficiency, scanty data on surgery is available to guide treatment strategies. The STER (Seven Treatment Evaluation Registry) is a multi-centre, prospective, observational, web-based study protocol providing the frame for a structured and detailed data collection. Inhibitor occurrence was checked in a centralized fashion. Forty-one surgical operations (24 'major' and 17 'minor') were performed in 34 subjects with a carefully characterized FVII deficiency under the coverage of recombinant activated Facto…
Can we compare haemophilia carriers with clotting factor deficiency to male patients with mild haemophilia?
2020
Introduction Certain haemophilia carriers demonstrate an increased bleeding tendency, mainly related to clotting factor deficiency. No study has so far formally compared the bleeding phenotype of women and girls with mild FVIII or FIX deficiency and associated management with that of male patients affected by mild haemophilia A and B. Material and methods We retrospectively evaluated 44 women and girls with mild FVIII or FIX deficiency (FVIII or FIX 0.05-0.5 IU/mL) and 77 male patients with mild haemophilia A or B and compared them with respect to clotting factor level, age at and trigger for diagnosis, as well as treatment modalities. Results After excluding gender-related haemorrhagic sym…