Search results for "blood gas analysis"

showing 10 items of 41 documents

Comparison of the gold standard of hemoglobin measurement with the clinical standard (BGA) and noninvasive hemoglobin measurement (SpHb) in small chi…

2015

Introduction Collecting a blood sample is usually necessary to measure hemoglobin levels in children. Especially in small children, noninvasively measuring the hemoglobin level could be extraordinarily helpful, but its precision and accuracy in the clinical environment remain unclear. In this study, noninvasive hemoglobin measurement and blood gas analysis were compared to hemoglobin measurement in a clinical laboratory. Methods In 60 healthy preoperative children (0.2-7.6 years old), hemoglobin was measured using a noninvasive method (SpHb; Radical-7 Pulse Co-Oximeter), a blood gas analyzer (clinical standard, BGAHb; ABL 800 Flex), and a laboratory hematology analyzer (reference method, la…

Malemedicine.medical_specialtyAccuracy and precisionHemoglobin levelsHemoglobinsPreoperative CaremedicineHumansProspective StudiesHemoglobin measurementChildBlood gas analysisbusiness.industrySmall childrenInfantReproducibility of ResultsGold standard (test)SurgeryAnesthesiology and Pain MedicineChild PreschoolPediatrics Perinatology and Child HealthFemaleObservational studyHemoglobinBlood Gas AnalysisNuclear medicinebusinessPediatric Anesthesia
researchProduct

Continuous monitoring of mixed venous oxygen saturation in infants after cardiac surgery

1989

Continuous mixed venous oxygen saturation (SvO2c) was measured in 16 infants immediately after cardiac surgery. A polyurethane 4F, dual channel catheter (Opticath, Modell U440, Oximetrix) with fiberoptic filaments was introduced into the pulmonary artery during cardiothoracic surgery. The catheters were left in place for an average of 67.5 h (range 27 h -125 h) and there were no catheter-related complications. Correlation between continuous in vivo SvO2 values and in vitro values was satisfactory (r = 0.85), whereas a correlation between SvO2c and arterial oxygen saturation (SaO2) was not found (r = 0.07). The sampled arterial lactate values were inversely correlated to the simultaneously m…

Malemedicine.medical_specialtyApparent oxygen utilisationchemistry.chemical_elementCritical Care and Intensive Care MedicineOxygenOxygen ConsumptionIntensive caremedicine.arteryHumansMedicinePostoperative PeriodCardiac Surgical ProceduresMonitoring Physiologicbusiness.industryContinuous monitoringInfantCardiac surgeryCatheterchemistryCardiothoracic surgeryAnesthesiaPulmonary arteryLactatesFemaleBlood Gas AnalysisbusinessIntensive Care Medicine
researchProduct

Endurance training in patients with chronic obstructive pulmonary disease: a comparison of high versus moderate intensity.

2000

Abstract Gimenez M, Servera E, Vergara P, Bach JR, Polu J-M. Endurance training in patients with chronic obstructive pulmonary disease: a comparison of high versus moderate intensity. Arch Phys Med Rehabil 2000;81:102-9. Purpose: To create a maximum tolerated 45-minute aerobic training program for patients with chronic obstructive pulmonary disease (COPD) and to compare its outcomes with those of commonly prescribed moderate exercise. Design: Prospective, randomized trial. Setting: A work physiology laboratory. Patients and Methods: The maximum exercise intensities that 7 COPD patients could sustain for 45 minutes were determined on a bilevel exercise ergometer. The patients then exercised …

Malemedicine.medical_specialtyErgometryPhysical exercisePhysical Therapy Sports Therapy and RehabilitationOxygen ConsumptionEndurance trainingHand strengthRespiratory muscleMedicineAerobic exerciseHumansLung Diseases ObstructiveOximetryProspective StudiesPeak flow metermeasurement_unitCOPDHand Strengthbusiness.industryRehabilitationMiddle Agedmedicine.diseaseExercise TherapyRespiratory Function TestsAnesthesiameasurement_unit.measuring_instrumentPhysical therapyBlood Gas AnalysisbusinessAnaerobic exerciseArchives of physical medicine and rehabilitation
researchProduct

PLASMA PROTEIN LOSS DURING SURGERY: BENEFICIAL EFFECTS OF ALBUMIN SUBSTITUTION

2001

Plasma protein loss during abdominal surgery is a known phenomenon, but its possible pathophysiological relevance has remained unknown. The present study evaluates the effects of albumin substitution on systemic and local hemodynamics and cellular interactions in the mesenteric microcirculation. Rats underwent median laparotomy and exteriorization of an ileal loop for intravital microscopy of the mesenteric microcirculation. Plasma protein concentrations, systemic and local hemodynamics were recorded during the follow up period, with or without albumin substitution. Depending on the time course of plasma protein loss in control experiments, 80% of the calculated protein loss was infused dur…

Malemedicine.medical_specialtyMean arterial pressureBlood Loss SurgicalHemodynamicsCritical Care and Intensive Care MedicineMicrocirculationRats Sprague-DawleyAlbuminsIntensive careInternal medicineAbdomenmedicineAnimalsSplanchnic Circulationbusiness.industryHemodynamicsAlbuminArteriesBlood ProteinsBlood proteinsRatsSurgeryEndocrinologyEmergency MedicineFemaleBlood Gas AnalysisbusinessIntravital microscopyAbdominal surgeryShock
researchProduct

Effects of Cortical Spreading Depression on Cortical Blood Flow, Impedance, DC Potential, and Infarct Size in a Rat Venous Infarct Model

2000

A cortical venous infarction model has been evaluated as to the degree of regional flow reduction and by studying effects of cortical spreading depression (CSD). Two adjacent cortical veins were occluded photochemically with rose bengal and fiberoptic illumination. Seven rats served to demonstrate effects on regional cortical blood flow using laser Doppler scanning. In 36 rats local CBF, DC potential, and brain tissue impedance were measured continuously for 75 min after vein occlusion. No, 3, or 10 CSD waves were induced by potassium chloride injection during the initial 75 min. Rats were compared for spontaneous CSDs; baseline local CBF, CBF, and impedance response to CSD; and infarct vol…

Malemedicine.medical_specialtyPhotochemistryHemodynamicsMembrane PotentialsPotassium ChlorideDevelopmental NeuroscienceInternal medicineElectric ImpedanceLaser-Doppler FlowmetrymedicineAnimalsRats WistarBrain MappingChemistryPenumbraCortical Spreading DepressionCerebral InfarctionBlood flowLaser Doppler velocimetryCerebral VeinsVein occlusionRatsDisease Models Animalmedicine.anatomical_structureNeurologyCerebral blood flowCerebral cortexCerebrovascular CirculationAnesthesiaCortical spreading depressionAcute Diseasecardiovascular systemCardiologyBlood Gas AnalysisIntracranial ThrombosisExperimental Neurology
researchProduct

Early extubation followed by immediate noninvasive ventilation vs. standard extubation in hypoxemic patients: a randomized clinical trial

2018

Purpose: Noninvasive ventilation (NIV) may facilitate withdrawal of invasive mechanical ventilation (i-MV) and shorten intensive care unit (ICU) length of stay (LOS) in hypercapnic patients, while data are lacking on hypoxemic patients. We aim to determine whether NIV after early extubation reduces the duration of i-MV and ICU LOS in patients recovering from hypoxemic acute respiratory failure. Methods: Highly selected non-hypercapnic hypoxemic patients were randomly assigned to receive NIV after early or standard extubation. Co-primary end points were duration of i-MV and ICU LOS. Secondary end points were treatment failure, severe events (hemorrhagic, septic, cardiac, renal or neurologic …

Malemedicine.medical_specialtyTime FactorsSedationmedicine.medical_treatmentWeaningAcute respiratory failureCritical Care and Intensive Care Medicinelaw.inventionHypoxemia03 medical and health sciences0302 clinical medicineTracheotomylawExtubationAnesthesiologymedicineHumansHypoxiaAgedMechanical ventilationChi-Square Distributionbusiness.industry030208 emergency & critical care medicineLength of StayMiddle Agedmedicine.diseaseIntensive care unitRespiration ArtificialPulmonary embolismIntensive Care Units030228 respiratory systemPneumothoraxItalyAnesthesiaBreathingAirway ExtubationFemalemedicine.symptomBlood Gas AnalysisbusinessVentilator WeaningNoninvasive ventilation
researchProduct

Exercise hyperventilation in chronic heart failure is not caused by systemic lactic acidosis

2005

Background: Patients with heart failure have an abnormally high ventilatory response to exercise associated with gas exchange defects and reduced arterial pCO2. Aims: We examined the possibility of lactic acidosis as the stimulus to this increased ventilation that abnormally depresses pCO2 during exercise in heart failure. Method and results: We studied 18 patients with chronic heart failure. We measured VE/VCO2 slope during exercise, arterial blood gases and lactate concentrations during cardiopulmonary exercise testing (rest, peak exercise and one minute after the end of exercise). Neither VE/VCO2 slope nor arterial pCO2 were related to arterial lactate concentrations at peak exercise (r=…

Malemedicine.medical_specialtypCO2Internal medicineHyperventilationmedicineHumansHyperventilationArterial pCO2AcidosisHeart FailureExercise Tolerancebusiness.industryMiddle AgedHydrogen-Ion Concentrationsmedicine.diseaseHeart failureLactic acidosisExercise TestCardiologyPhysical therapyArterial bloodAcidosis LacticFemaleBlood Gas Analysismedicine.symptomCardiology and Cardiovascular Medicinebusinesscirculatory and respiratory physiologyEuropean Journal of Heart Failure
researchProduct

A simple apparatus for deaerating and handling VAN SLYKE reagents for micro gasometers

1975

ManometryPhysiologyComputer scienceAirPhysiology (medical)Clinical BiochemistryIndicators and ReagentsNanotechnologyHuman physiologyBlood Gas AnalysisSimple (philosophy)Pfl�gers Archiv European Journal of Physiology
researchProduct

Spatial and temporal heterogeneity of ventilator-associated lung injury after surfactant depletion.

2008

Volutrauma and atelectrauma have been proposed as mechanisms of ventilator-associated lung injury, but few studies have compared their relative importance in mediating lung injury. The objective of our study was to compare the injury produced by stretch (volutrauma) vs. cyclical recruitment (atelectrauma) after surfactant depletion. In saline-lavaged rabbits, we used high tidal volume, low respiratory rate, and low positive end-expiratory pressure to produce stretch injury in nondependent lung regions and cyclical recruitment in dependent lung regions. Tidal changes in shunt fraction were assessed by measuring arterial Po2 oscillations. After ventilating for times ranging from 0 to 6 h, lu…

Pathologymedicine.medical_specialtyVentilator-associated lung injuryPhysiologyNitric Oxide Synthase Type IIInflammationEnzyme-Linked Immunosorbent AssayPulmonary EdemaRespiratory physiologyLung injuryPhysiology (medical)medicineAnimalsInterleukin 8LungChemokine CCL2PeroxidaseLungVentilators Mechanicalbusiness.industryRespiratory diseaseInterleukin-8Pulmonary SurfactantsLung Injuryrespiratory systemmedicine.diseasePulmonary edemarespiratory tract diseasesOxygenmedicine.anatomical_structureNeutrophil InfiltrationCalibrationRespiratory MechanicsCytokinesFluid TherapyFemaleRabbitsmedicine.symptomBlood Gas AnalysisChemokinesbusinessJournal of applied physiology (Bethesda, Md. : 1985)
researchProduct

Odd haemoglobins in odd-toed ungulates: Impact of selected haemoglobin characteristics of the white rhinoceros (Ceratotherium simum) on the monitorin…

2019

Background Due to the current poaching crisis in Africa, increasing numbers of white rhinoceroses (Ceratotherium simum) require opioid immobilisation for medical interventions or management procedures. Alarmingly, the results of both blood gas analysis and pulse oximetry regularly indicate severe hypoxaemia. Yet, the recovery of the animals is uneventful. Thus, neither of the techniques seems to represent the real oxygenation level. We hypothesized that unusual haemoglobin characteristics of this species interfere with the techniques developed and calibrated for the use in human patients. Methods Haemoglobin was isolated from blood samples of four adult, white rhinoceroses. Oxygen dissociat…

PhysiologyOxygenMethemoglobinAnalytical Chemistry0403 veterinary scienceHemoglobins0302 clinical medicineHigh oxygenMedicine and Health SciencesOximetryMammalsAnalgesicsMultidisciplinarybiologymedicine.diagnostic_testCeratotherium simumApplied MathematicsSimulation and ModelingQChemical ReactionsREukaryotaDrugs04 agricultural and veterinary sciencesHydrogen-Ion ConcentrationBody FluidsAnalgesics OpioidChemistryBloodSpectrophotometryPhysical SciencesVertebratesMedicineAnatomyAlgorithmsResearch ArticleChemical ElementsChemical Dissociation040301 veterinary sciencesAnimal TypesScienceEquineschemistry.chemical_elementRhinocerosResearch and Analysis MethodsAbsorbance03 medical and health sciencesChemical AnalysismedicineAnimalsHumansPain ManagementGas AnalysisDomestic AnimalsHorsesPerissodactylaPharmacologyChromatographyOrganismsBiology and Life SciencesOxygenationbiology.organism_classificationOxygenOpioidsPulse oximetry030228 respiratory systemchemistryAfricaAmniotesBlood Gas AnalysisZoologyMathematicsPLoS ONE
researchProduct