Search results for "boar"

showing 10 items of 337 documents

Biodeterioration of cardboard-based liquid containers collected for fibre reuse.

1999

Liquid packaging board (LPB) collected in Germany is processed in Finland as recycled fibre and as plastic reject for incineration. The chemical, biological and physical changes occurring in recycled LPB bales were monitored during storage of six and 18 months. The moisture content in the core of the bales ranged from 7% to 53%, and pH values varied from 6.0 to 8.5. The average amount of mesophilic bacteria per container was 1.5 x 10(7) - 5 x 10(8), which means that recycled LPB pulp cannot be recommended for sanitary use. The concentration of CO2 inside the bale is an indicator of the activity of aerobic microorganisms and might be suitable for identifying deteriorated bales and removing t…

PaperConservation of Natural ResourcesEnvironmental EngineeringInsectaHealth Toxicology and MutagenesisIncinerationengineering.materialLiquid packaging boardchemistry.chemical_compoundProduct PackagingEnvironmental ChemistryHumic acidAnimalsOrganic matterCelluloseOrganic ChemicalsSanitationCelluloseWater contentHumic Substanceschemistry.chemical_classificationWaste managementBacteriaPulp (paper)Public Health Environmental and Occupational HealthcardboardGeneral MedicineGeneral ChemistryPulp and paper industryPollutionRefuse DisposalBiodegradation Environmentalchemistryvisual_artvisual_art.visual_art_mediumengineeringPublic HealthMesophileChemosphere
researchProduct

Test procedures for obtaining representative extracts suitable for reliable in vitro toxicity assessment of paper and board intended for food contact.

2009

International audience; This paper describes the use of a suite of extraction procedures applicable to the assessment of the in vitro toxicity of paper/board samples intended for food-contact applications. The sample is extracted with ethanol, water, or exposed to modified polyphenylene oxide (Tenax) for fatty, non-fatty and dry food applications, respectively. The water extracts are directly suitable for safety assessment using in vitro bioassays. The ethanol extracts of the paper/board and of the exposed Tenax require pre-concentration to give acceptable sensitivity. This is because the in vitro bioassays can tolerate only a small percentage of added organic solvent before the solvent its…

PaperFood contact materialsHealth Toxicology and MutagenesisSample (material)[ SDV.TOX ] Life Sciences [q-bio]/ToxicologyTenax[SDV.TOX.TCA]Life Sciences [q-bio]/Toxicology/Toxicology and food chainIn Vitro TechniquesToxicologyPaper and boardMESH : Gas Chromatography-Mass Spectrometry01 natural sciencesMESH : Food PackagingGas Chromatography-Mass SpectrometryMESH : Toxicity Tests0404 agricultural biotechnologyToxicity TestsBioassayPaperboardMESH : WoodFood contactbusiness.industryTest procedures010401 analytical chemistryExtraction (chemistry)Food PackagingPublic Health Environmental and Occupational HealthLife Sciences04 agricultural and veterinary sciencesGeneral ChemistryGeneral MedicinePulp and paper industryToxicity assessmentWood040401 food science0104 chemical sciencesBiotechnologyMESH : PaperIn vitro testingExtraction proceduresFood contact materialsvisual_artvisual_art.visual_art_mediumEnvironmental sciencebusinessFood Science
researchProduct

Manufacturing and testing a thin glass mirror shell with piezoelectric active control

2015

Optics for future X-ray telescopes will be characterized by very large aperture and focal length, and will be made of lightweight materials like glass or silicon in order to keep the total mass within acceptable limits. Optical modules based on thin slumped glass foils are being developed at various institutes, aiming at improving the angular resolution to a few arcsec HEW. Thin mirrors are prone to deform, so they require a careful integration to avoid deformations and even correct forming errors. On the other hand, this offers the opportunity to actively correct the residual deformation: a viable possibility to improve the mirror figure is the application of piezoelectric actuators onto t…

Physics - Instrumentation and DetectorsMaterials scienceactive opticFOS: Physical sciencesMechanical engineeringpiezoelectric actuatorthin glass mirrorInstrumentation and Detectors (physics.ins-det)Settore ING-INF/01 - ElettronicaPiezoelectricitySignallaw.inventionPrinted circuit boardSettore FIS/05 - Astronomia E AstrofisicalawFocal lengthAngular resolutionPhotolithographyX-ray mirrorsAstrophysics - Instrumentation and Methods for AstrophysicsActuatorInstrumentation and Methods for Astrophysics (astro-ph.IM)VoltageSPIE Proceedings
researchProduct

The first coronal mass ejection observed in both visible-light and UV HI Ly-α channels of the Metis coronagraph on board Solar Orbiter

2021

Context.The Metis coronagraph on board Solar Orbiter offers a new view of coronal mass ejections (CMEs), observing them for the first time with simultaneous images acquired with a broad-band filter in the visible-light interval and with a narrow-band filter around the H ILy-αline at 121.567 nm, the so-called Metis UV channel.Aims.We show the first Metis observations of a CME, obtained on 16 and 17 January 2021. The event was also observed by the EUI/FSI imager on board Solar Orbiter, as well as by other space-based coronagraphs, such as STEREO-A/COR2 and SOHO/LASCO/C2, whose images are combined here with Metis data.Methods.Different images are analysed here to reconstruct the 3D orientation…

Physics010504 meteorology & atmospheric sciences[SDU.ASTR.SR]Sciences of the Universe [physics]/Astrophysics [astro-ph]/Solar and Stellar Astrophysics [astro-ph.SR]Sun: coronaSun: coronal mass ejections (CMEs)Astronomy and AstrophysicsAstrophysicsAlpha (navigation)Sun: UV radiation01 natural scienceslaw.inventionOn boardOrbiterSpace and Planetary Sciencelaw0103 physical sciencesCoronal mass ejectionMetis010303 astronomy & astrophysicsCoronagraphSun: atmosphere0105 earth and related environmental sciencesVisible spectrumSun: atmosphere – Sun: corona – Sun: UV radiation – Sun: coronal mass ejections (CMEs)
researchProduct

A coded mask for γ-ray astronomy. Design and calibration

2003

Abstract The high-resolution γ-ray spectrometer (SPI) is one of the two main instruments on board the ESA INTEGRAL satellite successfully launched in October 2002. SPI uses coded aperture mask technique in order to have imaging capabilities at the energy band (20 keV–8 MeV) it will study celestial sources. The SPI imaging performance depends critically on the quality of the coded mask response and also on the precise knowledge of such response function. In this paper we present a general description of the SPI Coded Mask design together with its main features. Scientific impact of INTEGRAL SPI Coded Mask design on the instrument capabilities is also discussed. Results obtained for Mask cali…

PhysicsNuclear and High Energy PhysicsSpectrometerbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaAstrophysics::Instrumentation and Methods for AstrophysicsIntegrated circuit layoutOn boardOpticsQuality (physics)CalibrationSatelliteCoded aperturebusinessInstrumentationRemote sensingNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

An optimized time screening algorithm for ROSAT PSPC and HRI observations

1998

We have developed a model-independent time screening optimization algorithm to cope with significant contamination spikes in the ROSAT PSPC/HRI bacground light-curves. The rejection criteria are based on the maximization of faint sources signal-to-noise ratio. The algorithm tuning parameters have been optimized through performing a wide set of runs on both simulated and real data. We have verified that the application of our selection criteria to the case of long exposure PSPC observations yields an increase of the number of faint sources ( SNR ) of up to 100% with a rejection of up to the 8% of the exposure time. At the same time, we obtain an average signal-to-noise ratio gain of 3% for t…

PhysicsOptimization algorithmbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaDetectorGeneral Physics and AstronomyAstrophysicsMaximizationScreening algorithmOn boardOpticsROSATInstrumentation (computer programming)businessAlgorithmSelection (genetic algorithm)
researchProduct

Ultra-low material pixel layers for the Mu3e experiment

2016

The upcoming Mu3e experiment will search for the charged lepton flavour violating decay of a muon at rest into three electrons. The maximal energy of the electrons is 53 MeV, hence a low material budget is a key performance requirement for the tracking detector. In this paper we summarize our approach to meet the requirement of about 0.1 % of a radiation length per pixel detector layer. This includes the choice of thinned active monolithic pixel sensors in HV-CMOS technology, ultra-thin flexible printed circuits, and helium gas cooling.

PhysicsPhysics - Instrumentation and DetectorsMuonPixel010308 nuclear & particles physicsbusiness.industryPhysics::Instrumentation and DetectorsDetectorComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONFOS: Physical sciencesElectronInstrumentation and Detectors (physics.ins-det)Tracking (particle physics)01 natural sciencesRadiation lengthPrinted circuit boardOptics0103 physical sciencesHigh Energy Physics::Experiment010306 general physicsbusinessInstrumentationMathematical PhysicsLepton
researchProduct

Prompt and Follow-up Multi-wavelength Observations of the GRB 161017A

2018

This paper presents data on the simultaneous and complementary observations of the gamma-ray burst (GRB) GRB 161017A for optical, X-ray, and gamma wavelengths obtained by the Russian multi-messenger Lomonosov space observatory and supplemented by additional data from the Swift satellite as well as the ground-based MASTER Global Robotic Net and the 10 m Gran Telescopio Canarias. Multifrequency spectra of this very powerful explosion indicate that it originated at a distance of 10 billion light years from Earth. Here, we present the results of the prompt, early, and afterglow optical observations. The light curves and spectra suggest that the prompt optical and high-energy emissions occur in …

PhysicsResearch program010308 nuclear & particles physicsAstrophysics::High Energy Astrophysical PhenomenaLibrary scienceGamma-ray burst: generalAstronomy and AstrophysicsMulti wavelength01 natural sciencesgeneral [Gamma-ray burst]On boardSpace and Planetary Science0103 physical sciencesChristian ministry010303 astronomy & astrophysics
researchProduct

Instantaneous root mean squire value of the acoustic emission as a means of measuring partial discharges

2003

The author presents the measurement results of the parameter A/sub RMS/ for three types of partial discharges (PDs) generated in a typical high-voltage system: on pressboard, on resin, and on glass. A typical run of A/sub RMS/ on an X-Y register is shown. It manifests a relatively stable instantaneous root mean square value of the electric signal converted from the acoustic signal as a function of time. Results obtained for the three surfaces demonstrate that the parameter A/sub RMS/ is perfectly suitable for characterizing PDs measured by the acoustic method. It is univocally connected with the energy of the generated PD. >

PhysicsRoot mean squarePressboardAcoustic emissionAnalytical chemistryRoot (chord)Value (computer science)Function (mathematics)SignalEnergy (signal processing)Computational physicsConference on Electrical Insulation and Dielectric Phenomena
researchProduct

Status of the EPIC thin and medium filters on-board XMM-Newton after more than 10 years of operation I: laboratory measurements on back-up filters

2013

After more than ten years of operation of the EPIC camera on board the X-ray observatory XMM-Newton, we have reviewed the status of its Thin and Medium filters by performing both laboratory measurements on back-up filters, and analysis of data collected in-flight. We have selected a set of Thin and Medium back-up filters among those still available in the EPIC consortium, and have started a program to investigate their status by different laboratory measurements including: UV/VIS transmission, X-ray transmission, RAMAN IR spectroscopy, X-Ray Photoelectron Spectroscopy, and Atomic Force Microscopy. We report the results of the measurements conducted up to now, and point out some lessons lear…

Physicsbusiness.industryAtomic force microscopyDetectorX-ray detectorEPICOn boardSettore FIS/05 - Astronomia E AstrofisicaOpticsObservatoryX-rays: XMM-Newton X-rays: instrumentation X-rays: filtersCalibrationData analysisbusinessSPIE Proceedings
researchProduct