Search results for "breath"
showing 10 items of 528 documents
A portable system for multiple parameters monitoring: towards assessment of health conditions and stress level in the automotive field
2019
In this work, an electronic portable combo system able to synchronously acquire multiple signals, e.g. electrocardiographic (ECG), photoplethysmographic (PPG) and breathing waveforms, is presented. The realized system is also capable of showing in real time some physiological parameters which can be used for assessing health/stress status of the volunteer, such as heart rate and breathing frequency and their trends over time. Thanks to the use of non-invasive PPG probes, of batteries as power supply, and to the possibility to add in the future additional sensors to acquire other signals, the system could also be employed inside vehicles for assessing the status of the driver. Finally, the r…
The EasyTube during general anesthesia for minor surgery
2017
BACKGROUND The EasyTube (EzT) is a supraglottic airway device that is used for emergency airway situations. Ventilation during general anesthesia should also be feasible, but literature on the EzT is scarce. We evaluated the EzT in comparison with the endotracheal tube (ETT) in its use during general anesthesia in a comparative study. METHODS A total of 400 patients with American Society of Anesthesiologists (ASA) physical status I to II scheduled for minor surgery in 4 centers were randomized for ventilation via the ETT or EzT. RESULTS In all patients, the EzT and the ETT could be inserted within 3 attempts. In all EzT patients, the inspiratory and expiratory minute volumes (6.64 ± 0.71 an…
Optical sensor for remote estimation of alcohol concentration in blood stream
2013
Abstract The purpose of this manuscript is to validate our recently developed novel optical approach for extraction of remote vibration sources as a successful technique to estimate the alcohol concentration in blood stream. This technique is based on the tracking of temporal changes of reflected secondary speckle patterns produced in human skin when being illuminated by a laser beam. Since the skin’s vibrations profile is changed due to the alcohol in the blood stream, the extraction of the vibration profile can be translated into the corresponding alcohol concentration values by means of defining several parameters acting as indicators for the presence of alcohol in the blood stream. We h…
Repeatability Study on a Classifier for Gastric Cancer Detection from Breath Sensor Data
2019
The SNIFFPHONE device is a portable multichannel gas sensor, aiming to detect gastric cancer (GC) from breath samples. It employs gold nanoparticle (GNP) sensors reacting to volatile organic compounds (VOCs) in the exhaled breath, a non-invasive technique to support early diagnosis. This study evaluates the repeatability of the SNIFFPHONE classification result for measurements conducted on healthy subjects over a short period of time of less than 10 minutes. Due to the portable nature of the device, repeatability is studied with respect to varying measurement location. We find the classification results repeatable with a statistically significant 81 % Pearson correlation coefficient, even t…
Perioperative diaphragm point-of-care ultrasound as a prediction tool of postoperative respiratory failure in high-risk patients: A feasibility study…
2021
Abstract Introduction Respiratory muscle function in the postoperative period is a key to whether a patient develops Postoperative Respiratory Failure (PRF) or not. PRF occurs when the gas exchange does not meet metabolic needs. Ipsilateral paralysis of the hemidiaphragm after interscalenic brachial plexus block (ISB) causes an acute reduction of respiratory muscle function. This reduction does not cause PRF when the contralateral hemidiaphragm generates enough gas exchange to meet metabolic demands. Objectives To study the evolution of hemidiaphragmatic muscle function during the perioperative period with diaphragmatic ultrasound (D-POCUS), and use it as an innovative tool to predict PRF, …
Blood CO2 and pH Transients During Apnoea after O2 Breathing in Patients
1990
Endotracheal intubation always is combined with an apnoea the duration of which is dependent on the technique used, the skills of the intubator, and the anatomical situation. The resulting typical potential risks may be (among others) both hypoxaemia and hypercapnia. Therefore the tolerable apnoea time for an intubation procedure is limited in clinical practice to 1 – 2 minutes. It must be noted that the developing hypercapnia is inevitable, whereas hypoxaemia may be avoided even in prolonged apnoea (e.g. >2 min) with “adaequate” preoxygenation [Duda et al., 1988]. Using de-nitrogenation techniques (breathing pure oxygen for 30 to 60 min) “anaesthetized and curarized normal subjects tolerat…
Health-related correlates of psychological well-being among girls and boys 6-8 years of age: The Physical Activity and Nutrition in Children study
2018
AIM Due to limited knowledge on the differences in the correlates of psychological well-being (PSWB) between girls and boys, we compared the correlates of PSWB between primary school girls and boys. METHODS A population sample of 412 children participated in the Physical Activity and Nutrition in Children study. Parents completed a questionnaire that included 19 questions on the components of PSWB, and a PSWB score was computed. We assessed correlates of PSWB, including physical activity, sedentary behaviour, cardiorespiratory fitness, diet quality, body fat content, sleep duration, sleep disordered breathing, prevalent diseases and parental characteristics. We used logistic regression to a…
Changes in pharyngeal aerobic microflora in oral breathers after palatal rapid expansion.
2006
Abstract Background The purpose of this study was to investigate in oral breathing children the qualitative and quantitative effects on aerobic and facultatively anaerobic oropharyngeal microflora of respiratory function improved by rapid palatal expansion (RPE). Methods In an open clinical trial, we studied 50 oral breathers, aged 8 to 14 years and suffering from both maxillary constriction and posterior cross-bite. At baseline, patients were examined by a single otorhinolaryngologist (ENT), confirming nasal obstruction in all subjects by posterior rhino-manometric test. Patients were evaluated three times by oropharyngeal swabs:1) at baseline (T = 0); 2) after palatal spreading out (T = 1…
Wache Videolaryngoskopie
2016
Introduction Awake video laryngoscopy is a novel option in airway management that is drawing more and more attention as an alternative to awake endoscopic guided intubation.Main issues: Intubation under preserved spontaneous breathing is the safest method to secure the expected difficult airway. In direct comparisons to awake flexible endoscopic intubation, awake video laryngoscopy achieves satisfactory intubation times and a high acceptance of patients and anesthesiologists. Specific cases, in particular very limited mouth opening or sub-glottic masses, require awake flexible endoscopic intubation. Sufficient topical anesthesia and a sophisticated sedation protocol are prerequisites for su…
Modular Breath Analyzer (MBA): Introduction of a Breath Analyzer Platform Based on an Innovative and Unique, Modular eNose Concept for Breath Diagnos…
2021
Exhaled breath analysis for early disease detection may provide a convenient method for painless and non-invasive diagnosis. In this work, a novel, compact and easy-to-use breath analyzer platform with a modular sensing chamber and direct breath sampling unit is presented. The developed analyzer system comprises a compact, low volume, temperature-controlled sensing chamber in three modules that can host any type of resistive gas sensor arrays. Furthermore, in this study three modular breath analyzers are explicitly tested for reproducibility in a real-life breath analysis experiment with several calibration transfer (CT) techniques using transfer samples from the experiment. The experiment …