Search results for "building simulation."
showing 10 items of 41 documents
Effect of Climate Change on Building Performance: the Role of Ventilative Cooling
2017
Climate Change represents a priority, due to the large variety of implications and importance that it has reached throughout the last decades. In an effort to address this global and local challenge and in order to restrict temperature rise to 2 °C over the next century, it will need to address this topic from several angles, as confirmed by the last COP meetings in Paris and in Marrakech. In this context, the paper presents the modelling and assessment of ventilative cooling applicability in the future of the Mediteranean area under the effects of climate change. Results show that natural ventilation will continue to be of paramount importance in the Mediterranean climate but its highest e…
BUILDING INTEGRATED PHASE CHANGE MATERIALS ENERGY STORAGE: EXPERIMENTAL STUDIES, MODELLING AND PARAMETRIC ANALYSIS
Data fusion analysis applied to different climate change models: an application to the energy consumptions of a building office
2018
The paper aims to achieve the modelling of climate change effects on heating and cooling in the building sector, through the use of the available Intergovernmental Panel on Climate Change forecasted data. Data from several different climate models will be fused with regards to mean air temperature, wind speed and horizontal solar radiation. Several climatic models data were analyzed ranging from January 2006 to December 2100. Rather than considering each model in isolation, we propose a data fusion approach for providing a robust combined model for morphing an existing weather data file. The final aim is simulating future energy use for heating and cooling of a reference building as a conse…
The Role of Natural Ventilative Cooling in NZE Temporary and Emergency Shelters Design: a Mediterranean Case Study
2016
The paper presents a case-study of a pre-fabricated housing module built in Messina (Sicily, Italy) and the assessment of its energy performances under the net zero energy perspective. The potential of ventilative natural cooling application in the case-study is also investigated. Some particular features of the building - the modularity, the prefabrication, the rapidity of assembly, the possibility of being built on disconnected soils and the absence of maintenance - identify an effective use as a temporary housing solution for e.g. workers in proximity of an isolated working place or in emergency situations such as earthquakes and natural disasters. Monitoring studies were performed durin…
A new approach to model the effect of climate change on the building sector: A climate models data fusion
2020
Several climate models have been developed and used to forecast the effects of the climate changes, however the variability of results due to different models lead to a significant uncertainty on the estimation of the building energy use for the next century. In this context, the paper analyses this uncertainty and combines different climate models in order to improve the robustness of energy consumption predictions. The data of the climate models were then used to generate hourly weather files for the future period 2020-2099 and energy simulations for a case study located in Palermo (Italy) were performed. Results show a wide variability among all models (either alone or combined with our …
LIFE CYCLE ASSESSMENT OF SOLAR COMMUNITIES: A SCENARIO ANALYSIS
The study proposes the comparisonof the life cycle performances of two different energy systems aimed at covering the needs of a large mixed-mode community, in Calgary (Canada). The two systems investigated are a“conventional” one, using heat pumps for heating, cooling and domestic hot water, and another one widely deploying solar thermal panels as well as a district heating infrastructure and a borehole seasonal thermal storage. The analysis is based on the LifeCycle Assessment (LCA) methodology and includes the stages of raw materials and energy supply, system manufacturing, use stage of the systems, generation and use of energy on-site, maintenance and components’ substitution, and explo…
Historical Buildings in protected areas in Italy: a re-design study of a rural building
2017
Historic and traditional buildings, including rural ones, are a territorial resource in Europe and constitute an integral part of the European’s cultural heritage. However they are often characterized by poor energy performances and a large potential for energy retrofit actions. On the other hand, the hardest part of retrofitting such buildings is the limited invasiveness that such actions need to have on the historical and heritage value of the building itself. The paper describes an experience of re-design of an existing rural building located in Sicily, inside the ancient Greeks “Valley of the Temples”. An energy audit was performed on the building, its energy uses thoroughly investigate…
Optimisation of Thermochromic Thin Films on Glass; Design of Intelligent Windows
2010
Theoretically thermochromic glazing has the potential to reduce energy consumption in buildings by allowing visible light for day lighting, reducing unwanted solar gain during the cooling season, while allowing useful solar gain in the heating season. In this study building simulation is used to predict the savings made by novel thermochromic glazing coatings compared to standard products, for locations with different climates. The results suggest that thermochromic glazing can have a significant energy saving effect compared to current approaches.
Natural ventilative cooling in school buildings in Sicily
2016
The paper shows analysis of the impact on thermal comfort of natural ventilation in a nonresidential Mediterranean case-study. Results are based on the EN 15251 approach on adaptive comfort. Different scenarios are proposed, granting an improvement of up to 10% in the number of summer comfort hours.
Comparison Between Conventional and Vegetated Roof by Means of a Dynamic Simulation
2015
In this paper, a dynamic simulation of a building located in the Campus University of Palermo, Italy, has been carried out. We considered two different scenarios; in the first one, the building as it is, with a conventional covering, while in the second one the roof was equipped with a green roof. The results of the two simulations have been compared, suggesting that such building component could contribute to the energy savings of the building. However, it has to be considered as part of other possible actions devoted to improve the energy efficiency of the whole building. (C) 2015 The Authors. Published by Elsevier Ltd. This is an open access article under the CC-BY-NC-ND license (http://…