Search results for "building"
showing 10 items of 1985 documents
Presentation, Management and Long-Term Outcome of Ureteropelvic Junction Obstruction in Duplex Kidneys.
2015
Ureteropelvic junction obstruction in association with a duplex collecting system is a rare but challenging upper urinary tract pathology. We report our 21-year experience with this anomaly in terms of presentation, diagnostic evaluation and management.We retrospectively identified all patients with ureteropelvic junction obstruction in a duplex collecting system between 1991 and 2012. We reviewed each case for presenting symptoms, anatomy and management. Median followup was 10.8 years (range 2 to 22).Ureteropelvic junction obstruction in duplex kidneys was diagnosed in 21 patients. Ten patients presented with clinical symptoms such as flank pain and urinary tract infection but 11 were asym…
Is avoidance of surgery possible in patients with perimenopausal ovarian tumors using transvaginal ultrasound and duplex color Doppler sonography?
1993
A total of 108 cases of small perimenopausal ovarian tumors (largest diameter, less than 7 cm) were evaluated by transvaginal sonography and duplex color Doppler sonography; 101 had criteria for benignity and 7 for malignancy. All cysts were punctured and aspirated to avoid unnecessary surgery (benign cases) and establish the cytologic diagnosis as well as to avoid the risk of leakage (malignant cases). Recurrence rate of benign punctured cysts was 25% within 1 year of follow up. No difference in recurrent rate was seen between pre- and postmenopausal patients (19 of 56 cases in the premenopausal group, and five of 28 cases in the postmenopausal group). The larger the cyst, the greater the …
Performance Analysis of Innovative Vacuum Insulation Panel
2013
Thermal insulation has become one of the central themes in energy behavior improvement. The use of insulating materials, from the thermal and hydrothermal aspect, allows the reduction of the heat transfer in each of the technical elements increasing their thermal inertia. Even if the research has led to the use of innovative materials with high values of thermal insulation, one of the main problems, which is difficult to resolve, is the thickness of the building envelope to reach levels of transmittance that can allow considerable savings of energy and CO2 emissions. With this objective the VIP (Vacuum Insulation Panel) technology in building applications is an innovative solution to obtain…
An agent-based model to support the preliminary design and operation of heating and power grids with cogeneration units and photovoltaic panels in de…
2022
The increase in the energy demands of residential neighborhoods constitutes a huge challenge to be faced. A viable option lies in the insertion of both renewable energy production systems and cogeneration units within urban territories. On-site production allows for the satisfaction of the heating and electrical demands of end-users and favors the distribution of produced energy within the neighborhood, especially under the regulatory framework of energy communities. This paper proposes a tool to model heating and electricity networks integrated with cogeneration units and PV panels installed in urban areas. The tool accounts for the following possibilities: (i) energy flow management and p…
Green geopolymeric concrete using grits for applications in construction
2018
Abstract This work investigates the production a green geopolymer-based concrete for a sustainable construction material using biomass wastes from a kraft pulp industry: fly ash (as main alumina-silicate source) and grits (as aggregate). Moreover, a simple, reproducible, ambient temperature, and low-cost manufacture is followed. Mix design aims to maximize wastes incorporation and optimize the mechanical performance. Preliminary tests indicate that the used wastes may be successfully employed to produce green geopolymeric concretes with satisfying mechanical performance (up to 18 MPa), according to the European standards. Furthermore, they represent a viable solution to reduce the environme…
Dynamic Mechanical Behavior Analysis of Flax/Jute Fiber-Reinforced Composites under Salt-Fog Spray Environment
2020
Over the last decades, natural fiber-reinforced polymer composites (NFRPs) gained great attention in several engineering fields thanks to the reduction of the environmental impact and the end-of-life cost disposal. Unfortunately, the use of NFRPs is limited, mainly due to their weak resistance against humid environments. Since limited literature is available about the evolution of the dynamic mechanical response of NFRPs under aggressive environments, this paper aims to investigate the damping properties of flax, jute and flax/jute epoxy composites exposed to salt-fog up to 60 days. Furthermore, sodium bicarbonate fiber treatment was performed to improve the composites&rsquo
Towards a new mix design method for asphalt mixtures containing rap
2016
Recycling is one of the most important aspects to conceive the new construction or rehabilitation of sustainable road infrastructures. Even if Reclaimed Asphalt Pavement (RAP) is commonly used in the practice, its presence may lead to some critical aspects due to the physical and chemical phenomena occurring during the new mix process. For instance, the formation of RAP clusters during a new mix may inhibit the uniform distribution of the virgin binder as well as cause changes in the design grading curve of the mixture. Indeed, laboratory results demonstrate that small-size RAP particles stick together forming clusters. The amount of clusters depends on different parameters observed: The pe…
Effects of Air Tightness Tests on Steel Thin-Wall Box Structures with Circular and Rectangular Cross Sections
2019
In this paper, the effects of air tightness tests on steel box structures with rectangular or circular cross sections typical of port cranes (legs, arms, and crosspieces) are analyzed. Legs and arms are generally made with elements with profiles having a square or rectangular cross section, while the diagonal struts are made with profiles having circular cross sections. To verify the air tightness of these elements, a necessary requirement to protect them from corrosion if they are not protected with other protection techniques, air tightness tests are performed. These tests, in the framework of durability tests, must be carried out while maintaining the structure elasticity well below the …
Sacelli "dimenticati" nell’area urbana di Akragas
2016
International audience; Between 1927 and 1930, Pirro Marconi investigated a small rectangular structure near house Filippazzo, in the central urban area of Akragas. The presence of a bothros and fragments of female figures with stephane suggested the presence of a small sanctuary or themenos for chthonic deities. The little news published by Marconi and the vague indication of location made us forget the existence of this sanctuary for many years. However, a survey carried out in 2016 allowed to identify the remains of Marconi’s structure, partly covered by ground. At the same time, other little-known structures have been identified. In some cases, their function is still unknown.
An improved algorithm for thermal dynamic simulation of walls using Z-transform coefficients
2003
The Transfer Function Method (TFM), recommended by American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), is one of the most modern tools available to solve heat transfer problems in building envelopes and environments. TFM utilises Z-transform to solve the equations system that describes the heat transfer in a multi-layered wall. Due to an analogy with an electric circuit, it is possible to write the equations system in a matrix suitable to be solved by computer. Authors carried out an analysis on an historical building placed in the south of Italy to test the reliability and the quality of the thermal dynamic simulation using TFM. The analysis is performed usi…