Search results for "cadence"

showing 10 items of 55 documents

Definition of the thermographic regions of interest in cycling by using a factor analysis

2016

Abstract Research in exercise physiology using infrared thermography has increased in the last years. However, the definition of the Regions of Interest (ROIs) varies strongly between studies. Therefore, the aim of this study was to use a factor analysis approach to define highly correlated groups of thermographic ROIs during a cycling test. Factor analyses were performed based on the moment of measurement and on the variation of skin temperatures as a result of the cycling exercise. 19 male participants cycled during 45 min at 50% of their individual peak power output with a cadence of 90 rpm. Infrared thermography was used to measure skin temperatures in sixteen ROIs of the trunk and lowe…

0206 medical engineeringSkin temperature02 engineering and technologyCondensed Matter Physics020601 biomedical engineering01 natural sciencesTrunkAtomic and Molecular Physics and Opticsnervous system diseasesElectronic Optical and Magnetic Materials010309 opticsMoment (mathematics)nervous systemmental disorders0103 physical sciencesThermographyPrincipal component analysisExercise physiologyCyclingCadencepsychological phenomena and processesMathematicsBiomedical engineeringInfrared Physics & Technology
researchProduct

Nordic walking influence on biomechanical parameters: a systematic review

2020

INTRODUCTION Nordic walking (NW) as a form of physical activity has been shown to have benefits in various domains, but little is known about the effect of NW on more specific biomechanical parameters. The purpose is to determine the impact of NW on the following parameters: walking speed/distance, muscle activation, spatiotemporal parameters, kinematics and ground reaction force. EVIDENCE ACQUISITION A literature search was carried out in different databases from October 2008 to October 2018. This review was conducted and reported in accordance with the PRISMA statement. Finally, 42 studies with a median PEDro Score of 5.5/10 were included. EVIDENCE SYNTHESIS The included studies reported …

030506 rehabilitationmedicine.medical_specialtyWalk TestPhysical Therapy Sports Therapy and RehabilitationWalkingKinematics03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationmedicineHumansGround reaction forceExercise physiologyMuscle SkeletalExerciseGaitbusiness.industryRehabilitationMuscle activationBiomechanical PhenomenaPreferred walking speed0305 other medical scienceRange of motionCadencebusiness030217 neurology & neurosurgeryEvidence synthesisEuropean Journal of Physical and Rehabilitation Medicine
researchProduct

Foot Strike Pattern, Step Rate, and Trunk Posture Combined Gait Modifications to Reduce Impact Loading during Running

2019

Elevated impact loading can be detrimental to runners as it has been linked to the increased risk of tibial stress fracture and plantar fasciitis. The objective of this study was to investigate the combined effects of foot strike pattern, step rate, and anterior trunk lean gait modifications on impact loading in runners. Nineteen healthy runners performed 12 separate gait modification trials involving: three foot strike patterns (rearfoot, midfoot, and forefoot strike), two step rates (natural and 10% increased), and two anterior trunk lean postures (natural and 10-degree increased flexion). Overall, forefoot strike combined with increased step rate led to the lowest impact loading rates, a…

AdultMaleFoot strikelanding patternmedicine.medical_specialtyFractures Stress0206 medical engineeringBiomedical EngineeringBiophysicsPlantar fasciitis02 engineering and technologyRunningjuoksu03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationGait (human)medicineHumansOrthopedics and Sports MedicineRange of Motion ArticularTrunk postureta315GaitpostureryhtiFootbusiness.industryForefootRehabilitationvertical loadingTorso020601 biomedical engineeringTrunkBiomechanical PhenomenaTibial Fracturesbody regionsImpact loadingFemalecadencebiomekaniikkamedicine.symptombusinessCadencehuman activities030217 neurology & neurosurgerydistance runnersJournal of Biomechanics
researchProduct

Medial gastrocnemius muscle behavior during human running and walking.

2007

Utilization of elastic energy in the tendinous tissues (TT) of the human skeletal muscle may be task dependent. The present study was designed to investigate this problem by comparing the fascicle-TT interaction of the medial gastrocnemius muscle (MG) during ground contact of running and walking. Seven subjects ran and walked with a natural cadence. Ankle and knee joint angular data were recorded by electrogoniometers for estimating the entire MG muscle-tendon unit (MTU) length, together with the ground reaction forces. The MG fascicle length was measured by using the high-speed ultrasound image scanning during movements. The results showed that in running, after the rapid early fascicle st…

AdultMaleMaterials scienceMuscle RelaxationMuscle Fibers SkeletalBiophysicsMedial gastrocnemiusWalkingKnee JointSarcomereRunningmedicineHumansOrthopedics and Sports MedicineGround reaction forceMuscle SkeletalUltrasonographyLegElectromyographyRehabilitationSkeletal muscleAnatomyFasciclemedicine.anatomical_structureAnkleCadenceMuscle ContractionGaitposture
researchProduct

Muscle-tendon interaction and elastic energy usage in human walking

2005

The present study was designed to explore how the interaction between the fascicles and tendinous tissues is involved in storage and utilization of elastic energy during human walking. Eight male subjects walked with a natural cadence (1.4 ± 0.1 m/s) on a 10-m-long force plate system. In vivo techniques were employed to record the Achilles tendon force and to scan real-time fascicle lengths for two muscles (medial gastrocnemius and soleus). The results showed that tendinous tissues of both medial gastrocnemius and soleus muscles lengthened slowly throughout the single-stance phase and then recoiled rapidly close to the end of the ground contact. However, the fascicle length changes demonstr…

AdultMalePhysiologyMedial gastrocnemiusWalkingModels BiologicalTendonsElastic recoilPhysiology (medical)Image Interpretation Computer-AssistedmedicineHumansComputer SimulationMuscle SkeletalUltrasonographyAchilles tendonChemistryElastic energyAnatomyFasciclemusculoskeletal systemAdaptation PhysiologicalTendonmedicine.anatomical_structureEnergy Transfermedicine.symptomCadenceAnkle JointMuscle ContractionMuscle contraction
researchProduct

Cycling exercise and the determination of electromechanical delay.

2007

The main aim of the present paper was to address the validity of a methodology proposed in a previous paper [Li L, Baum BS. Electromechanical delay estimated by using electromyography during cycling at different pedaling frequencies. J Electromyogr Kinesiol 2004;14(6):647-52], aimed at determining the electromechanical delay from pedaling exercise performed at various cadences. Twelve trained subjects undertook pedaling bouts corresponding to combinations of cadences ranging from 50 to 100 RPM and power output from 37.5% to 75% of Pmax. As cadence increased, peak torque angle was found to shift forward in crank cycle (from 60-65 degrees at 50 RPM to 75-80 degrees at 100 RPM, depending on th…

AdultMaleTime FactorsKnee JointPhysical ExertionBiophysicsNeuroscience (miscellaneous)ElectromyographyControl theoryTask Performance and AnalysismedicineTorqueMuscular forceHumansPower outputMuscle SkeletalMathematicsCrankmedicine.diagnostic_testCoactivationBicyclingTorqueExercise TestHip JointNeurology (clinical)CadenceCyclingMuscle ContractionJournal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology
researchProduct

Muscle activation during cycling at different cadences: Effect of maximal strength capacity

2007

International audience; The purpose of this study was to examine the influence of maximal strength capacity on muscle activation, during cycling, at three selected cadences: a low cadence (50 rpm), a high cadence (110 rpm) and the freely chosen cadence (FCC). Two groups of trained cyclists were selected on the basis of the different maximal isokinetic voluntary contraction values (MVCi) of their lower extremity muscles as follow: Fmin (lower MVCi group) and Fmax (higher MVCi group). All subjects performed three 4-min cycling exercises at a power output corresponding to 80 % of the ventilatory threshold under the three cadences. Neuromuscular activity of vastus lateralis (VL), rectus femoris…

AdultMalemedicine.medical_specialtyAnaerobic ThresholdErgometryfreely chosen cadence[SHS.SPORT.PS] Humanities and Social Sciences/Sport/Sport physiologyBiophysicsNeuroscience (miscellaneous)[SHS.SPORT.PS]Humanities and Social Sciences/Sport/Sport physiologytorqueElectromyographyBiceps[ SHS.SPORT ] Humanities and Social Sciences/SportQuadriceps MusclePhysical medicine and rehabilitationOxygen ConsumptionEMGInternal medicineIsometric ContractionMaximal strengthmedicineHumansPower outputMuscle StrengthMuscle Skeletal[SHS.SPORT]Humanities and Social Sciences/Sportmedicine.diagnostic_testChemistryElectromyography[ SHS.SPORT.PS ] Humanities and Social Sciences/Sport/Sport physiology[SHS.SPORT] Humanities and Social Sciences/SportMuscle activationBicyclingBiomechanical PhenomenaLower ExtremityCardiologyPhysical EnduranceNeurology (clinical)cyclistsCadenceCyclingVentilatory thresholdforceMuscle Contraction
researchProduct

Noninvasive Determination of Anaerobic Threshold Based on the Heart Rate Deflection Point in Water Cycling

2015

This study compared heart rate (HR), oxygen uptake (V[Combining Dot Above]O2), percentage of maximal HR (%HRmax), percentage of maximal V[Combining Dot Above]O2, and cadence (Cad) related to the anaerobic threshold (AT) during a water cycling maximal test between heart rate deflection point (HRDP) and ventilatory (VT) methods. In addition, the correlations between both methods were assessed for all variables. The test was performed by 27 men in a cycle ergometer in an aquatic environment. The protocol started at a Cad of 100 b·min-1 for 3 minutes with subsequent increments of 15 b·min-1 every 2 minutes until exhaustion. A paired two-tailed Student's t-test was used to compare the variables …

AdultMalemedicine.medical_specialtyAnaerobic ThresholdPhysical Therapy Sports Therapy and Rehabilitation03 medical and health sciencesOxygen Consumption0302 clinical medicineHeart RateInternal medicineHeart ratemedicineHumansCycle ergometerOrthopedics and Sports Medicine030212 general & internal medicineCorrelation testMathematics030229 sport sciencesGeneral MedicineOxygen uptakeHealthy VolunteersAquatic environmentWater cyclingExercise TestCardiologyRegression AnalysisCadenceAnaerobic exerciseJournal of Strength and Conditioning Research
researchProduct

Effect of pedalling rates on physiological response during endurance cycling

2001

International audience; This study was undertaken to examine the effect of different pedalling cadences upon various physiological responses during endurance cycling exercise. Eight well-trained triathletes cycled three times for 30 min each at an intensity corresponding to 80% of their maximal aerobic power output. The first test was performed at a freely chosen cadence (FCC); two others at FCC-20% and FCC +20%, which corresponded approximately to the range of cadences habitually used by road racing cyclists. The mean (SD) FCC, FCC-20% and FCC + 20% were equal to 86 (4), 69 (3) and 103 (5) rpm respectively. Heart rate (HR), oxygen uptake (VO2), minute ventilation (VE) and respiratory excha…

AdultMalemedicine.medical_specialtyCadencePhysiology[SHS.SPORT.PS]Humanities and Social Sciences/Sport/Sport physiology03 medical and health sciencesOxygen Consumption0302 clinical medicineAnimal scienceHeart RatePhysiology (medical)Heart ratemedicineHumansOrthopedics and Sports MedicinePower outputExerciseRespiratory exchange ratioFatiguePulmonary Gas ExchangeChemistry[ SHS.SPORT.PS ] Humanities and Social Sciences/Sport/Sport physiologyPublic Health Environmental and Occupational Health030229 sport sciencesGeneral MedicineOxygen uptakeBicyclingIntensity (physics)Oxygen uptakeTriathletesPhysical EndurancePhysical therapyCadenceCycling030217 neurology & neurosurgeryRespiratory minute volumeEuropean Journal of Applied Physiology
researchProduct

Is Moderate Intensity Cycling Sufficient to Induce Cardiorespiratory and Biomechanical Modifications of Subsequent Running?

2017

Walsh, JA, Dawber, JP, Lepers, R, Brown, M, and Stapley, PJ. Is moderate intensity cycling sufficient to induce cardiorespiratory and biomechanical modifications of subsequent running? J Strength Cond Res 31(4): 1078-1086, 2017-This study sought to determine whether prior moderate intensity cycling is sufficient to influence the cardiorespiratory and biomechanical responses during subsequent running. Cardiorespiratory and biomechanical variables measured after moderate intensity cycling were compared with control running at the same intensity. Eight highly trained, competitive triathletes completed 2 separate exercise tests; (a) a 10-minute control run (no prior cycling) and, (b) a 30-minut…

AdultMalemedicine.medical_specialtyRespiratory rateSTRIDEPhysical Therapy Sports Therapy and Rehabilitation030204 cardiovascular system & hematologyAthletic PerformanceRunning03 medical and health sciences[ SDV.NEU.SC ] Life Sciences [q-bio]/Neurons and Cognition [q-bio.NC]/Cognitive SciencesYoung Adult0302 clinical medicineOxygen Consumption[SDV.MHEP.CSC]Life Sciences [q-bio]/Human health and pathology/Cardiology and cardiovascular systemRespiratory RateModerate ExerciseHeart RateInternal medicineHeart ratemedicineHumansOrthopedics and Sports MedicineRespiratory exchange ratioCardiorespiratory PhysiologyChemistry[SDV.NEU.SC]Life Sciences [q-bio]/Neurons and Cognition [q-bio.NC]/Cognitive SciencesCardiorespiratory fitnessCycling030229 sport sciencesGeneral Medicine[ SDV.MHEP.CSC ] Life Sciences [q-bio]/Human health and pathology/Cardiology and cardiovascular systemIntensity (physics)BicyclingBiomechanical PhenomenaTriathlon.AthletesCardiologyExercise TestCadenceCyclingJournal of strength and conditioning research
researchProduct