Search results for "cataract surgery"

showing 10 items of 82 documents

Subjective photic phenomena with refractive multifocal and monofocal intraocular lenses. results of a multicenter questionnaire.

2001

Abstract Purpose To compare the incidence and severity of photic phenomena after the implantation of the Array® (Allergan) refractive multifocal intraocular lens (MIOL) and a monofocal IOL. Setting Multicenter study at Kiel, Mainz, Karlsruhe, and Bremerhaven, Germany. Methods The study comprised 231 randomly selected patients from 4 study centers. The patients had had uneventful phacoemulsification with implantation of a refractive MIOL (n = 138) or a monofocal IOL (n = 93). By questionnaire, patients were asked whether they experienced light sensations postoperatively (light streaks, halos, flare, flashes, or glare) that had not been noticed preoperatively. Additional questions evaluated w…

genetic structuresLightmedicine.medical_treatmentEye diseaseVision DisordersIntraocular lensGlareVision disorderLens Implantation IntraocularSurveys and QuestionnairesmedicineHumansLenses IntraocularPhacoemulsificationbusiness.industryIncidenceGlare (vision)PhacoemulsificationMultifocal intraocular lensCataract surgerymedicine.diseaseeye diseasesSensory SystemsOphthalmologyMulticenter studyOptometrySurgerysense organsmedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

Multifokale Intraokularlinsen

2001

Modern cataract surgery has developed tremendously during the past 10-15 years. Improved surgical techniques, as well as improved implant materials and designs, have enlarged patient profiles and indications for cataract surgery. This also created much higher expectations from the patients' site. The loss of accommodation is loss of quality of life for presbyopic and especially young pseudophakic patients. Therefore cataract surgery with multifocal IOL implantation is not only of academic interest, but reflects demands and expectations of our patients. Multifocal IOLs have been implanted since 1986, starting with 2-3 zone refractive and diffractive designs. Due to surgical techniques of tha…

genetic structuresmedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentEye diseaseGlare (vision)Intraocular lensCataract surgeryCorneal topographymedicine.diseaseAphakiaeye diseasesOphthalmologymedicineOptometryMultifocal IOLssense organsImplantbusinessDer Ophthalmologe
researchProduct

Penetration of 2% cyclosporin eyedrops into human aqueous humour.

1989

The penetration into the eye and the systemic absorption of 2% cyclosporin eye drops were determined by polarisation immunofluorescent assay of cyclosporin in the aqueous humour and plasma of 30 patients at the time of cataract surgery. The results were then compared with the corresponding results after oral administration at a dosage of 5 mg/kg/day to three further patients. The maximum intraocular concentration (24 (SD 9) mg/l) was achieved four hours after topical administration. This level was slightly less than that found in aqueous humour (28 (SD 10) mg/l) 12 hours after systemic administration of the drug at a dosage of 5 mg/kg/day. Both these levels are below the minimum therapeutic…

genetic structuresmedicine.medical_treatmentEye diseaseCyclosporinsPharmacologyAbsorptionAqueous HumorCellular and Molecular NeurosciencePharmacokineticsOral administrationCyclosporin amedicineHumansAgedAqueous humourbusiness.industryCataract surgeryMiddle Agedmedicine.diseaseSensory Systemseye diseasesOphthalmologyAnesthesiaSystemic administrationsense organsOphthalmic SolutionsbusinessUveitisResearch ArticleThe British journal of ophthalmology
researchProduct

Binocular vision alterations after refractive and cataract surgery: a review.

2018

To review binocular and accommodative disorders documented after corneal or intraocular refractive surgery, in normal healthy prepresbyopic patients. A bibliographic revision was performed; it included works published before 1st July 2017 where accommodation and/or binocularity was assessed following any type of refractive surgical procedure. The search in Pubmed yielded 1273 papers, 95 of which fulfilled the inclusion criteria. Few publications reporting binocular vision and/or accommodative changes after refractive surgery in normal subjects were found. The reduction in fusional vergence is the most frequently reported alteration. Anisometropia is an important risk factor for postoperativ…

genetic structuresmedicine.medical_treatmentUlls -- Acomodació i refraccióEstrabismeCataract Extraction:Ciències de la visió::Optometria::Visió binocular [Àrees temàtiques de la UPC]:Ciències de la visió::Optometria::Acomodació i refracció [Àrees temàtiques de la UPC]Eye--Accommodation and refraction03 medical and health sciences0302 clinical medicinePostoperative ComplicationsRefractive surgerymedicineDiplopiaHumansAnisometropiaVision Binocularbusiness.industryVision TestsCataractes -- CirurgiaFusional vergenceAccommodation OcularGeneral MedicineCataract surgerymedicine.diseaseVisió binoculareye diseasesRefractive Surgical ProceduresStrabismusContact lensOphthalmologyAccommodative convergenceCataract -- Surgery030221 ophthalmology & optometryOptometryBinocular visionbusinessBinocular visionAccommodation030217 neurology & neurosurgeryActa ophthalmologica
researchProduct

Endothelial cells loss to the hyperopic pacients during phacoemulsification

2018

Introduction The phacoemulsification cataract surgery is the most frequently performed surgery and it generally improves vision in over 90% of the patients. Hyperopic patients are a challenge during phacoemulsification especially because of their short eyeball and shallow anterior chamber. A shallow anterior chamber is associated with overall reduction of the safe zone, which may lead to difficulty in creating the corneal incisions, harder capsulorhexis performing, or endothelial complications. Purpose The aim of the study was to present the endothelial cells loss after the phacoemulsification procedure in the hyperopic patients. Material and methods A number of 1775 patients operated in th…

hyperopiaspecular microscopyCorneal endotheliummedicine.medical_specialtygenetic structuresEndotheliummedicine.medical_treatmentHypermetropiaEmmetropiaCataractLens Implantation IntraocularCorneaOphthalmologymedicineHumansCapsulorhexisPhacoemulsificationbusiness.industryEndothelium Cornealshallow anterior chamberEndothelial CellsGeneral MedicinePhacoemulsificationCataract surgeryeye diseasesmedicine.anatomical_structureGeneral ArticlesbusinessRomanian Journal of Ophthalmology
researchProduct

Proteome alterations in aqueous humour of primary open angle glaucoma patients.

2019

Aim To unravel the primary open angle glaucoma (POAG) related proteomic changes in aqueous humour (AH). Methods Totally 35 patients listed for cataract surgery (controls: n=12, age: 67.4±13.6y) or trabeculectomy for POAG (n=23, age: 72.5±8.3y) were included. AH samples of those patients were obtained during cataract surgery or trabeculectomy. AH samples were subsequently pooled into the experimental groups under equal contribution in terms of protein amount of each individual patient. Protein samples were analyzed by a linear trap quadrupol Orbitrap Mass Spectrometry device with an upstream liquid chromatography system. The obtained raw data were analyzed using the Maxquant proteome softwar…

medicine.medical_specialtyApolipoprotein DOpen angle glaucomagenetic structuresmedicine.medical_treatmentGlaucomaproteomicslcsh:OphthalmologyOphthalmologyMedicineTrabeculectomywnt signaling pathwaybusiness.industryAqueous humourBrief ReportCataract surgerymedicine.diseaseFold changeprimary open angle glaucomaeye diseasesOphthalmologylcsh:RE1-994Proteomesense organsbusinessaqueous humorInternational journal of ophthalmology
researchProduct

Determining postoperative anterior chamber depth

2003

Abstract Purpose: To compare measured and calculated postoperative anterior chamber depths (ACDs). Setting: Department of Ophthalmology and Institute of Medical Physics, University of Vienna, Vienna, Austria, and Department of Ophthalmology, University of Mainz, Mainz, Germany. Methods: The postoperative ACD was measured in 189 pseudophakic eyes using a laboratory prototype of partial coherence interferometry (PCI). In 6 intraocular lens (IOL) groups, the mean ACD was calculated by ray tracing based on the best-known A-constants of the SRK formulas. In addition, for each IOL type, each measured ACD was compared with a value calculated using the individual spherical equivalent of the postope…

medicine.medical_specialtyBiometryLightPseudophakiaAnterior Chambermedicine.medical_treatmentIntraocular lensSpherical equivalentLens Implantation IntraocularPower calculationsOphthalmologymedicineHumansPostoperative PeriodLenses Intraocularbusiness.industryModels TheoreticalCataract surgeryRefractionSensory SystemsOphthalmologyInterferometryPartial coherence interferometryConventional PCISurgerybusinessJournal of Cataract and Refractive Surgery
researchProduct

Bacterial Contamination of Anterior Chamber Fluid Following Non-complicated Cataract Surgery

1993

Objective: To study the anterior chamber contamination during non-complicated cataract surgery and its relationship with normal conjuctival organisms. Setting: Ophthalmology Department, La Fe Hospital, University of Valencia. Patients: Forty patients who had undergone cataract extraction using either ECCE, phacoemulsification or nucleus fracture methods. Results: Positive cultures of aqueous humour were obtained in 32.5% of cases. The most commonly isolated organism was Staphylococcus coagulase-negative. Only in 7.7% of cases was the microorganism found in the conjunctiva the same as that found in the anterior chamber. The inoculum size ranged between 20 and 160 colonies/ml. One of the case…

medicine.medical_specialtyConjunctivabusiness.industryAqueous humourmedicine.medical_treatmentIntraocular lensPhacoemulsificationUlls CirurgiaContaminationCataract surgerymedicine.disease_causemedicine.diseaseeye diseasesSurgeryOphthalmologymedicine.anatomical_structureEndophthalmitisOphthalmologymedicinesense organsbusinessStaphylococcusEuropean journal of Implant and Refractive Surgery
researchProduct

Fluocinolone acetonide vitreous insert for chronic diabetic macular oedema: a systematic review with meta-analysis of real-world experience

2021

AbstractWe conducted a meta-analysis of real-world studies on the 0.19 mg Fluocinolone Acetonide (FAc) intravitreal implant for chronic diabetic macular oedema (DMO), comparing these findings with the Fluocinolone Acetonide for Diabetic Macular Edema (FAME) study. The primary outcome was mean change of best corrected visual acuity (BCVA) at 24 months. Secondary outcomes were 36-month mean BCVA, mean central macular thickness (CMT) change, rates of eyes receiving supplementary intravitreal therapy, cataract surgery, intraocular pressure (IOP)-lowering drops and glaucoma surgery. Mean differences (MDs) with 95% confidence intervals (CIs) were calculated. Nine real-world studies were included.…

medicine.medical_specialtyIntraocular pressuregenetic structuresSciencemedicine.medical_treatmentAnti-Inflammatory AgentsArticleMacular Edema03 medical and health sciences0302 clinical medicineDiabetes complicationsFluocinolone acetonideOphthalmologymedicineGlaucoma surgeryHumans030212 general & internal medicineGlucocorticoidsIntraocular PressureDrug ImplantsDiabetic RetinopathyMultidisciplinarybusiness.industryQRCataract surgeryRetinal diseaseseye diseasesConfidence intervalFluocinolone AcetonideDiabetic macular oedemaMeta-analysis030221 ophthalmology & optometryMedicinesense organsImplantbusinessmedicine.drugScientific Reports
researchProduct

Prävention des früh-postoperativen IOD-Anstiegs nach Phakoemulsifikation

2001

Purpose. To compare the ocular hypotensive effect of different antiglaucomatous eye drops. Patients and methods. This double-blind, randomized study included 119 eyes of 119 patients without other ocular pathology undergoing standardized (one surgeon, Healon) small incision cataract surgery with foldable intraocular lens implantation.The patients were assigned to one of five groups: group 1:0.25% timolol in Gelrite (extended efficacy, n=23); group 2: 2% dorzolamide (n=24); group 3: combination of 0.5% timolol plus 2% dorzolamide (n=22); group 4: brimonidine (n=26); group 5: gentamicin (control, n=24). Intraocular pressure (IOP) was measured preoperatively and at 3±1,6±1,9±1,24±3, and 48±3 h…

medicine.medical_specialtyIntraocular pressuregenetic structuresbusiness.industrymedicine.medical_treatmentBrimonidineTimololIntraocular lensPhacoemulsificationCataract surgeryeye diseasesOphthalmologyDorzolamideOphthalmologyStatistical significancemedicinebusinessmedicine.drugDer Ophthalmologe
researchProduct