Search results for "cataract"
showing 10 items of 195 documents
Visual Acuity and Contrast Sensitivity in Eyes Implanted with Aspheric and Spherical Intraocular Lenses
2009
Purpose To compare visual acuity and contrast sensitivity (CS) in eyes implanted with aspheric and spherical intraocular lenses (IOLs) after cataract surgery. Design Randomized, prospective study. Participants Five hundred twenty-four eyes from 262 cataract surgery patients implanted with 2 IOL models: the AcrySof IQ (262 eyes) and AcrySof SN60AT (262 eyes; Alcon Laboratories, Fort Worth, TX). Methods High-contrast photopic best-corrected distance visual acuity (BCVA) and CS under photopic (85 cd/m 2 ) and mesopic (6 cd/m 2 ) conditions were measured. Pupil diameter was analyzed for distance vision under both lighting conditions. Follow-up was carried out for 6 months in all patients. Main …
Effect of partial and full correction of corneal spherical aberration on visual acuity and contrast sensitivity
2008
A 60-year-old white man had cataract surgery with an AcrySof IQ intraocular lens (IOL) implanted in the right eye and a Tecnis IOL implanted in the left eye. The ocular spherical aberration (SA) target for a 6.0 mm pupil was +0.10 microm for the right eye and 0 microm for the left eye. After surgery, the ocular SA in the right eye was significantly higher than that in the left eye (+0.112 microm +/- 0.002 [SD] versus +0.021 +/- 0.003 microm; P.001). No between-eye difference in the best corrected visual acuity and photopic contrast sensitivity was found. The contrast sensitivity was significantly better in the eye with the AcrySof IQ IOL at 12 and 18 cpd under mesopic conditions. The best c…
Axial Elongation following Cataract Surgery during the First Year of Life in the Infant Aphakia Treatment Study
2012
PURPOSE To compare ocular axial elongation in infants after unilateral cataract surgery corrected with a contact lens (CL) or primary intraocular lens (IOL) implantation. METHODS Baseline axial length (AL) was measured at the time of cataract surgery (1-6 months) and at age 1 year. AL at baseline and age 1 year and the change in length/mo were analyzed in relation to treatment modality, cataractous versus fellow eye, and age at surgery using linear mixed models. RESULTS Mean baseline AL did not differ between the CL and IOL groups for either cataractous or fellow eyes. Eyes with cataracts were shorter than fellow eyes by an average of 0.6 mm (95% confidence interval [CI], 0.4-0.8 mm; P < 0.…
The combination of diffractive and refractive multifocal intraocular lenses to provide full visual function after cataract surgery.
2009
PURPOSE To investigate if implantation of a far dominant refractive multifocal intraocular lens (IOL) in one eye and a near dominant diffractive multifocal IOL in the fellow eye improves range of vision following cataract surgery. METHODS This was a prospective, nonrandomized, case-control study involving 20 patients (40 eyes) scheduled for cataract surgery. Inclusion criteria were bilateral cataracts, minimum age 50 years, availability for follow-up visits, and informed consent. All patients received a far dominant refractive multifocal IOL (ReZoom, Abbott Medical Optics) in their dominant eye and a near dominant diffractive multifocal IOL (Tecnis ZM900, AMO) in their nondominant eye. Preo…
Late postoperative opacification of MemoryLens hydrophilic acrylic intraocular lenses Case series and review
2003
Abstract Purpose: To report clinical and spectrographic analyses of 2 explanted hydrophilic acrylic intraocular lenses (IOLs). Setting: John A. Moran Eye Center, Salt Lake City, Utah, USA, and Johannes Gutenberg-University, Department of Ophthalmology, Mainz, Germany. Methods: We report 6 cases of opacification of MemoryLens ® IOLs (Ciba Vision) that occurred approximately 2 years after implantation. The anterior and posterior surfaces of the IOLs had a white, frosted appearance, and the IOLs' interior looked brown, similar to the appearance of a brunescent cataract. Two of the IOLs were explanted because of a significant decrease in visual acuity. The IOLs were sent for further clinicopath…
Efficacy and Safety of Mass Cataract Surgery Campaign in a Developing Country
2012
To determine the visual outcomes achieved in terms of efficacy and safety during a mass eye surgery campaign in a low-income developing country.Three hundred fifteen eyes of 305 patients underwent extracapsular cataract extraction with intraocular lens implantation in a prospective, analytical, experimental, and nonrandomized study on patients who underwent cataract surgery during the campaign that two Spanish nongovernmental organizations conducted in December 2008 in a district hospital in Bobo-Dioulasso (Burkina Faso).Mean age was 61.97 ± 14.39 years. The mean uncorrected distance visual acuity before surgery was 2.17 ± 0.7 (20/3000), which improved to 0.86 ± 0.64 logMAR (20/150) 3 month…
TRANSCONJUNCTIVAL NONVITRECTOMIZING VITREOUS SURGERY VERSUS 25-GAUGE VITRECTOMY IN PATIENTS WITH EPIRETINAL MEMBRANE
2015
Purpose: To compare the clinical outcomes and the rate of complications of 27-gauge transconjunctival nonvitrectomizing vitreous surgery (NVS) and of 25-gauge transconjunctival sutureless vitrectomy surgery for idiopathic epiretinal membrane removal. Methods: In this prospective randomized study, 83 phakic eyes of 83 consecutive patients with an idiopathic epiretinal membrane were randomized to receive 27-gauge NVS (NVS-group) or 25-gauge vitrectomy (Standard-group). Main outcome measures were best-corrected visual acuity, central retinal thickness, nuclear density units' changes, and rate of complications. Results: Thirty-nine eyes of the Standard-group and 40 of the NVS-group were conside…
Visual outcomes and complications of congenital cataract surgery
2019
Corresponding author at: Department of Ophthalmology, 14, rue Paul-Gaffarel, 21000 Dijon, France. This work is issued from the oral presentation during the 123rd congress of the French Ophthalmological Society.; International audience; PURPOSE: To describe the visual results and postoperative complications of congenital cataract surgeries performed between 2005 and 2016. METHODS: A retrospective consecutive case series of congenital cataract surgeries was carried out at the Dijon University Hospital in France. Intraocular lens implantation was primary or secondary according to age. Pre- and post-operative assessment was performed through ophthalmologic consultations with orthoptic measureme…
Factors influencing myopic shift in children after intraocular lens implantation.
2019
Introduction:Intraocular lenses have always been a controversial topic in pediatric cataract surgery. In the early 1990s in the post-Soviet states of Eastern Europe, intraocular lenses promised an easier full-time correction and amblyopia treatment. Since 1991, ophthalmologists in Latvia have been implanting intraocular lenses in infants. Amount of the postoperative myopic shift and its influencing factors, analyzed in this article, are important indicators of congenital cataract treatment.Materials and methods:A retrospective chart review off 85 children (137 eyes) who underwent foldable posterior chamber intraocular lens implantation at the Clinical University Hospital in Riga, Latvia, fr…
Multifocal intraocular lenses for unilateral cataract in children.
2009
Purpose To evaluate the implantation of apodized diffractive multifocal intraocular lenses (IOLs) in children with unilateral cataract. Setting Ophthalmology Service, Hospital Clinico Lozano Blesa, Zaragoza, Spain. Design Prospective clinical study. Methods Five children between 4 and 6 years of age with unilateral cataract had cataract extraction and implantation of an apodized diffractive multifocal IOL (AcrySof Restor SN60D3). Phacoaspiration was accompanied by posterior capsulorhexis followed by an anterior vitrectomy. Uncorrected distance (UDVA), corrected distance (CDVA), and corrected near (CNVA) visual acuities; binocular function using the Worth 4-dot test and the TNO stereotest; a…