Search results for "cataract"
showing 10 items of 195 documents
Evaluation of the practicality of optical biometry and applanation ultrasound in 253 eyes
2003
Abstract Purpose To evaluate the percentage of eyes that could not be measured using optical biometry and ultrasound applanation and the reasons. Setting Department of Ophthalmology, Johannes Gutenberg-University Hospital, Mainz, Germany. Methods Optical biometry (IOLMaster®, Carl Zeiss Meditec AG) and A-scan ultrasound biometry were performed consecutively in 253 eyes scheduled for cataract surgery the next day. Lens opacities were evaluated with the Opacity Lensmeter (Interzeag), and a slitlamp examination and measurement of visual acuity were performed. The 2 techniques were compared in terms of the rate of and reasons for primary measurement failure. Results Measurement with the IOLMast…
Further delineation of a rare recessive encephalomyopathy linked to mutations in GFER thanks to data sharing of whole exome sequencing data
2017
Background Alterations in GFER gene have been associated with progressive mitochondrial myopathy, congenital cataracts, hearing loss, developmental delay, lactic acidosis and respiratory chain deficiency in 3 siblings born to consanguineous Moroccan parents by homozygosity mapping and candidate gene approach (OMIM#613076). Next generation sequencing recently confirmed this association by the finding of compound heterozygous variants in 19-year-old girl with a strikingly similar phenotype, but this ultra-rare entity remains however unknown from most of the scientific community. Materials and methods Whole exome sequencing was performed as part of a "diagnostic odyssey" for suspected mitochon…
Phenotypical features of two patients diagnosed with PHARC syndrome and carriers of a new homozygous mutation in the ABHD12 gene.
2018
Abstract PHARC (Polyneuropathy, Hearing loss, Ataxia, Retinitis pigmentosa and Cataracts) (MIM# 612674 ) is an autosomal recessive neurodegenerative disease caused by mutations in the ABHD12 gene. We evaluated two Spanish siblings affected with pes cavus, sensorimotor neuropathy, hearing loss, retinitis pigmentosa and juvenile cataracts in whom the genetic test of ABHD12 revealed a novel homozygous frameshift mutation, c.211_223del (p.Arg71Tyrfs*26). The earliest clinical manifestation in these patients was a demyelinating neuropathy manifested with a Charcot-Marie-Tooth phenotype over three decades. Progressive hearing loss, cataracts and retinitis pigmentosa appeared after the age of 30. …
Posterior chamber phakic intraocular lenses to correct high myopia: A comparative study between Staar and Adatomed models
2001
ABSTRACT PURPOSE: To determine the feasibility of using posterior chamber phakic intraocular lenses (PIOLs) to treat high myopia, comparing two different models, Staar and Adatomed. METHODS: Twenty-four eyes from 12 patients were studied prospectively. A phakic Staar IOL was implanted in one eye of each patient, and the other eye received a phakic Adatomed IOL. Patients with uveitis or ocular trauma prior to ocular surgery, diabetic retinopathy, or capsular pseudoexfoliation were excluded. The mean preoperative spherical equivalent refraction was -16.00 ± 5.05 D for the Staar group and -15.39 ± 2.83 D for the Adatomed group. Average follow-up was 32.4 months (range, 19 to 46 mo) for the Ada…
Combined procedure for glaucoma and cataract: A retrospective study
1994
Abstract To ascertain the long-term effects of a triple procedure in the case of coexisting cataract and glaucoma, we did a retrospective study of 93 eyes that had cataract extraction, IOL implantation, and trabeculectomy within a ten-year period. Mean follow-up was 32.4 ± 21.9 months. Mean postoperative intraocular pressure (IOP) was significantly lower than preoperatively, even though fewer medications were being used. One year after surgery, 60% of eyes had a best corrected visual acuity of 20/40 or better with an average improvement of 3.8 Snellen lines. Patients who had had surgery four or more years before the study had the highest percentage of eyes with an IOP exceeding 22 mm Hg. Th…
Healon5 versus Viscoat during cataract surgery: intraocular pressure, laser flare and corneal changes
2000
Background: The use of a viscoelastic substance facilitates cataract surgery. Healon 5 is a new viscoelastic product with special rheological properties. We evaluated the postoperative effect of Viscoat and Healon5 on intraocular pressure (IOP), central corneal thickness (CCT), endothelial cell counts and laser flare. Methods: Forty-eight eyes of 48 patients undergoing routine phacoemulsification followed by foldable IOL implantation were enrolled. Either Healon5 or Viscoat was used according to a block- randomization scheme. The aspiration technique was standardized. IOP, CCT, endothelial cell counts and laser flare were compared pre- and postoperatively. Statistical analysis was performed…
Intraocular pressure after small incision cataract surgery: temporal sclerocorneal versus clear corneal incision.
2001
To compare intraocular pressure (IOP) after phacoemulsification and foldable intraocular lens (IOL) implantation using a temporal sclerocorneal or clear corneal incision.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.One hundred patients (100 eyes) with cataract having phacoemulsification with posterior chamber IOL implantation were randomly assigned to receive a temporal sclerocorneal or clear corneal tunnel incision. Intraocular pressure was measured preoperatively and 6 hours, 1, 2, and 3 days, and 5 months postoperatively. Statistical significance was determined by nonparametric group comparisons using 2-sample random Wilcoxon tests.Six hours postoperatively,…
Biaxial Microincision versus Coaxial Small-Incision Clear Cornea Cataract Surgery
2005
Objective To compare clinical outcomes of biaxial microincision (1.5 mm) and coaxial small-incision (2.75 mm) clear cornea cataract surgery. Design Randomized controlled clinical trial. Participants Seventy eyes of 70 patients were examined at a German university eye hospital. Intervention The 70 patients (70 eyes) were assigned randomly (1:1) to a biaxial or conventional coaxial incision group. Both groups underwent phacoemulsification using pulsed ultrasound energy with variable duty cycles, followed by microincision intraocular lens implantation. Main Outcome Measures Best-corrected visual acuity (BCVA), astigmatism, laser flare photometry value, effective phacoemulsification time (EPT),…
Optical coherence tomography of macular thickness after biaxial vs coaxial microincision clear corneal cataract surgery
2009
PURPOSE To evaluate macular thickness changes after biaxial microincision versus coaxial small incision cataract surgery using optical coherence tomography (OCT). METHODS This prospective, randomized, marked study comprised 70 patients (70 eyes) undergoing biaxial microincision surgery or conventional coaxial phacoemulsification. Patients were evaluated by Stratus OCT preoperatively and 1 day, 4 weeks, and 8 weeks postoperatively. Best-corrected visual acuity (BCVA), phacoemulsification power, and effective phacoemulsification time (EPT) were evaluated. RESULTS In the biaxial group, median foveal thickness changed from 160 microm preoperatively to 168 microm 8 weeks postoperatively (p=0.018…
Incidence of posterior vitreous detachment after cataract surgery
2009
Purpose To report the incidence of posterior vitreous detachment (PVD) after uneventful state-of-the-art small-incision phacoemulsification with implantation of a posterior chamber intraocular lens (PC IOL). Setting Department of Ophthalmology, Ludwigshafen Hospital, Ludwigshafen, Germany. Methods This prospective study evaluated the vitreous status of eyes by biomicroscopic examination, indirect binocular ophthalmoscopy, and B-scan ultrasonography before planned cataract surgery. Patients with the posterior vitreous attached were included for follow-up and examined 1 week, 1 month, and 1 year after uneventful phacoemulsification with PC IOL implantation. The preoperative prevalence and pos…