Search results for "cathode"

showing 10 items of 296 documents

ALICE T0 detector

2005

T0-the fast timing and trigger detector for the ALICE experiment at CERN LHC-is described. Performance of the T0 prototype measured with a mixture of 6 GeV/c negative pions and kaons is given. The best time resolution (28 ps r.m.s.) was reached with a radiator diameter matching that of the photocathode. The results for all the tested radiator sizes are considerably better than 50 ps-the minimum requirement for the ALICE experiment.

PhysicsNuclear and High Energy PhysicsPhotomultiplierLarge Hadron ColliderPhysics::Instrumentation and DetectorsCherenkov detectorDetectorPhotocathodelaw.inventionNuclear physicsPionNuclear Energy and EngineeringlawRadiator (engine cooling)High Energy Physics::ExperimentElectrical and Electronic EngineeringALICE (propellant)Nuclear ExperimentIEEE Transactions on Nuclear Science
researchProduct

Recent results with lifetime enhanced microchannel-plate photomultipliers

2018

Abstract The favored photon sensors for the DIRC (detection of internally reflected Cherenkov light) detectors at the PANDA (Anti-proton Annihilation at Darmstadt) experiment at FAIR (Facility for anti-proton and ion research) are micro-channel-plate photomultipliers (MCP-PMTs). The main problem until a few years ago was the limited lifetime of the MCP-PMTs caused by a rapid decrease in quantum efficiency (QE) of the photo cathode (PC) with increasing integrated anode charge (IAC). These limitations are overcome by applying an atomic layer deposition (ALD) coating on the MCPs, as recently done by PHOTONIS and Hamamatsu. During the last years’ tests of lifetime enhanced MCP-PMTs were perform…

PhysicsNuclear and High Energy PhysicsPhotomultiplierPhoton010308 nuclear & particles physicsbusiness.industry01 natural sciencesCathode030218 nuclear medicine & medical imagingAnodelaw.invention03 medical and health sciencesAtomic layer deposition0302 clinical medicineOpticsDetection of internally reflected Cherenkov lightlaw0103 physical sciencesQuantum efficiencyMicrochannel plate detectorbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Improved lifetime of microchannel-plate PMTs

2014

Abstract The charged particle identification at the PANDA experiment will be mainly performed with DIRC detectors. Because of their advantageous properties the preferred photon sensors are MCP-PMTs. However, until recently these devices showed serious aging problems which resulted in a diminishing quantum efficiency (QE) of the photo cathode. By applying innovative countermeasures against the aging causes, the manufacturers recently succeeded in drastically improving the lifetime of MCP-PMTs. Especially the application of an ALD coating technique to seal the material of the micro-channels proves very powerful and results in a lifetime of ≈ 6 C / cm 2 integrated anode charge without a substa…

PhysicsNuclear and High Energy PhysicsPhotomultiplierPhotonbusiness.industryDetectorNanotechnologyengineering.materialCathodeAnodelaw.inventionCoatinglawengineeringOptoelectronicsQuantum efficiencyMicrochannel plate detectorbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

UTSW Small Animal Positron Emission Imager

2006

A Small Animal Imager (SAI) for PET has been designed, built, tested in phantoms, and applied to investigations in mice and rats. The device uses principles based on gamma-ray induced scintillation in crossed fiber optic detectors connected to Position Sensitive Photomultiplier Tubes (PSPMT). Each detector consists of an epoxied stack of 28 layers of 135 round 1 mm BCF-10 scintillating plastic fibers. The overlap region forms a 13.5times13.5times2.8 cm3 detector volume. Scintillating light from the fibers is detected by two (X and Y directions) Hamamatsu R-2486 PSPMTs with 16 anode wires in each of two orthogonal directions. A centroid-finding algorithm gives the position of a light cluster…

PhysicsNuclear and High Energy PhysicsPhotomultiplierScintillationOptical fiberPhotonbusiness.industryDetectorIterative reconstructionPhotocathodelaw.inventionOpticsNuclear Energy and EngineeringlawElectrical and Electronic EngineeringbusinessImage resolutionIEEE Transactions on Nuclear Science
researchProduct

Design and status of COMPASS FAST-RICH

2006

In the context of the upgrade of COMPASS RICH-1, we are developing a fast photodetection system for RICH counters, based on UV extended Multi-Anode PhotoMultiplier Tubes (MAPMT) and a custom, low dead-time electronic readout system. Photons are concentrated on the MAPMT photocathode by an optical system that preserves the position information. The ratio between the collection and the photosensitive surfaces is ∼7.5 in our design, larger than in previous applications. A new front-end electronics, based on a modified version of the MAD4 discriminator chip, is being realized to digitize the MAPMT signals. We report about the design of the photodetection system and of the associated electronic …

PhysicsNuclear and High Energy PhysicsPhotomultiplierbusiness.industryContext (language use)PhotodetectionChipPhotocathodeOpticsUpgradeCompassElectronicsbusinessInstrumentation
researchProduct

Breakthrough in the lifetime of microchannel plate photomultipliers

2015

Abstract Cherenkov detectors using the DIRC (Detection of Internally Reflected Cherenkov Light) principle are foreseen for particle identification in the P ¯ ANDA experiment at FAIR. Promising sensors for the detection of the Cherenkov light are the so-called micro-channel plate (MCP) photomultipliers (PMT). They have an excellent time resolution, can be operated at high gain for single photon detection and have a high resistivity against magnetic fields. The disadvantage of these devices was their limited lifetime, due to damage by feedback ions on the photocathode. The lifetime of various types of MCP-PMTs from different manufactures has been tested under conditions similar to that in the…

PhysicsNuclear and High Energy PhysicsPhotomultiplierbusiness.industryDetectorPhotocathodeAtomic layer depositionOpticsDetection of internally reflected Cherenkov lightQuantum efficiencyMicrochannel plate detectorbusinessInstrumentationCherenkov radiationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Fast photon detection for COMPASS RICH-1

2007

A fast photon detection system has been built and assembled for the upgrade of COMPASS RICH-1. The system is based on multianode photomultipliers coupled to fused silica lenses to collect the light from a larger surface and to guide it to the photocathode, preserving the position information. The emphasis is on the fast response and high rate capability of the detectors and the associated electronics. The photon detection system is now ready and it will be employed in the 2006 COMPASS data taking. We report about the system design and construction.

PhysicsNuclear and High Energy PhysicsPhotomultiplierbusiness.industryUV lensesEmphasis (telecommunications)DetectorCOMPASSPhotocathodeOpticsUpgradePhoton detectionCompassCOMPASS; RICH; Multianode photomultiplier tubes; UV lenses; Photon detectionMultianode photomultiplier tubesSystems designElectronicsbusinessInstrumentationRICH
researchProduct

Recent developments with microchannel-plate PMTs

2017

Abstract Microchannel-plate (MCP) PMTs are the favored photon sensors for the DIRC detectors of the PANDA experiment at FAIR. Until recently the main drawback of MCP-PMTs were serious aging effects which led to a limited lifetime due to a rapidly decreasing quantum efficiency (QE) of the photo cathode (PC) as the integrated anode charge (IAC) increased. In the latest models of PHOTONIS and Hamamatsu an innovative atomic layer deposition (ALD) technique is applied to overcome these limitations. During the last five years comprehensive aging tests with ALD coated MCP-PMTs were performed and the results were compared to tubes treated with other techniques. The QE in dependence of the IAC was m…

PhysicsNuclear and High Energy PhysicsPhoton010308 nuclear & particles physicsbusiness.industryDetector01 natural sciencesCathode030218 nuclear medicine & medical imagingAnodelaw.invention03 medical and health sciencesWavelengthAtomic layer deposition0302 clinical medicineOpticslaw0103 physical sciencesQuantum efficiencyMicrochannel plate detectorbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Tremendously increased lifetime of MCP-PMTs

2017

Abstract Microchannel plate (MCP) PMTs are very attractive photon sensors for low light level applications in strong magnetic fields. However, until recently the main drawback of MCP-PMTs was their aging behavior which manifests itself in a limited lifetime due to a rapidly decreasing quantum efficiency (QE) of the photo cathode (PC) as the integrated anode charge (IAC) increases. In the latest models of PHOTONIS, Hamamatsu, and BINP novel techniques are applied to avoid these aging effects which are supposed to be mainly caused by feedback ion impinging on the PC and damaging it. For more than four years we are running a long-term aging test with new lifetime-enhanced MCP-PMT models by sim…

PhysicsNuclear and High Energy PhysicsPhoton010308 nuclear & particles physicsbusiness.industryengineering.material01 natural sciencesCathode030218 nuclear medicine & medical imagingAnodeIonlaw.invention03 medical and health sciencesAtomic layer deposition0302 clinical medicineOpticsCoatinglaw0103 physical sciencesengineeringQuantum efficiencyMicrochannel plate detectorbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Coherent Smith-Purcell radiation for minimally invasive bunch length measurement at the subpicosecond time scale

2021

Physical review accelerators and beams 24(4), 042803 (2021). doi:10.1103/PhysRevAccelBeams.24.042803

PhysicsNuclear and High Energy PhysicsPhysics and Astronomy (miscellaneous)010308 nuclear & particles physicsbusiness.industryScale (descriptive set theory)QC770-798Surfaces and InterfacesRadiation53001 natural sciencesMeasure (mathematics)Superconducting acceleratorSpace chargeLength measurementOpticsNuclear and particle physics. Atomic energy. Radioactivity0103 physical sciencesCathode rayPhysics::Accelerator Physicsddc:530010306 general physicsbusinessBeam (structure)Physical Review Accelerators and Beams
researchProduct