Search results for "cellar"

showing 10 items of 230 documents

Micellar liquid chromatography: suitable technique for screening analysis.

2002

The screening capability of micellar liquid chromatography (MLC) is discussed using the reported chromatographic data of several sets of compounds (amino acids, beta-blockers, diuretics, phenethylamines, phenols, polynuclear aromatic hydrocarbons, steroids and sulfonamides) and new results (sulfonamides and steroids). The chromatographic data are treated with an interpretive optimisation resolution procedure to obtain the best separation conditions. Usually, the pH and the concentration of surfactant (sodium dodecyl sulfate, SDS, or cetyltrimethylammonium bromide) for the optimal mobile phase were 2.5-3 and0.12 M, respectively. The nature and concentration of organic solvent depended on the…

ChromatographyElutionOrganic ChemistryGeneral MedicineReversed-phase chromatographyBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryPropanolPartition coefficientchemistry.chemical_compoundColumn chromatographychemistryPharmaceutical PreparationsMicellar liquid chromatographySodium dodecyl sulfateChromatography LiquidJournal of chromatography. A
researchProduct

Volumes and compressibilities of pentanol in aqueous alkyltrimethylammonium bromide solutions at different temperatures

1990

Speed of sound and density properties of ternary water-tetradecyltrimethylammonium bromide-pentanol system at 15, 25 and 35°C and of water-hexadecyltrimethylammonium bromide-pentanol system at 25, 35 and 45°C were measured at fixed alcohol concentration as a function of surfactant concentration. The apparent molar volumes Vϕ,R and isentropic compressibilities Kϕ,RS of pentanol in micellar solutions as a function of the surfactant concentration show irregular behavior which depends on the alkyl chain length of the surfactant and tends to disappear with increasing temperature. These anomalies are ascribed to micellar transitions. For both surfactants at high concentrations, Vϕ,R decrease and …

ChromatographyIsentropic processChemistryDistribution constanttechnology industry and agricultureBiophysicsThermodynamicsPrimary alcoholBiochemistryApparent molar propertyMolar volumePulmonary surfactantPhase (matter)Micellar solutionslipids (amino acids peptides and proteins)Physical and Theoretical ChemistryMolecular BiologyJournal of Solution Chemistry
researchProduct

Modelling of retention behaviour of solutes in micellar liquid chromatography

1997

In micellar liquid chromatography (MLC), the resolution for a given multi-component mixture can be optimized by changing several variables, such as the concentrations of surfactant and organic modifier, the pH and temperature. However, this advantage can only be fully exploited with the development of mathematical models that describe the retention and the separation mechanisms. Several reports have appeared recently on the possibilities of accurately predicting the solute retention in MLC. Although the retention and selectivity may strongly change with varying concentrations of surfactant, organic modifier and/or pH, the observed changes are very regular, and are well described by simple m…

ChromatographyMathematical modelResolution (mass spectrometry)ChemistryOrganic ChemistryGeneral MedicineBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryPulmonary surfactantMicellar liquid chromatographyIonic strengthCritical micelle concentrationSelectivityJournal of Chromatography A
researchProduct

Reliability of the retention factor estimations in liquid chromatography.

2004

The retention factor is one of the most universally used parameters in chromatography. However, large differences in the experimental retention factor values are observed when the same compound is injected in a given stationary/mobile phase system under intermediate precision conditions. Conventional protocols for estimating retention factors have problems that mainly arise from difficulties in the hold-up time measurements and the omission of the existence of extra-column times by practicing chromatographers. In the present paper, three different approaches for estimating retention factors are tested: (i) classical retention factor estimations based on the gross hold-up time, (ii) based on…

ChromatographyMicellar liquid chromatographyChemistryOrganic ChemistrySpectrophotometry UltravioletGeneral MedicineBiochemistryRetention timeReliability (statistics)Analytical ChemistryChromatography LiquidJournal of chromatography. A
researchProduct

Micellar Liquid Chromatography: Method Development and Applications

2015

ChromatographyMicellar liquid chromatographyChemistryReversed-phase chromatographyMethod development
researchProduct

Capillary electrophoresis for analyzing pesticides in fruits and vegetables using solid-phase extraction and stir-bar sorptive extraction.

2005

Two procedures based on solid-phase extraction (SPE) and stir-bar sorptive extraction (SBSE) in combination with micellar electrokinetic chromatography (MEKC)--diode array detection (DAD) were compared for the simultaneous extraction of acrinathrin, bitertanol, cyproconazole, fludioxonil, flutriafol, myclobutanil, pyriproxyfen, and tebuconazole in lettuce, tomato, grape, and strawberry. Selectivity and resolution of the MEKC procedure were studied changing the pH and the molarity of the buffer, the type and the concentration of surfactant, and the methanol content in the mobile phase. A buffer consisting of 6 mM sodium tetraborate decahydrate with 75 mM of cholic acid sodium solution (pH 9.…

ChromatographyMolar concentrationMyclobutanilSodiumOrganic Chemistrychemistry.chemical_elementElectrophoresis CapillaryGeneral MedicineBiochemistrySensitivity and SpecificityMicellar electrokinetic chromatographyAnalytical Chemistrychemistry.chemical_compoundCapillary electrophoresischemistryFruitVegetablesSample preparationSolid phase extractionPesticidesQuantitative analysis (chemistry)Journal of chromatography. A
researchProduct

Quantitative retention–structure and retention–activity relationships of barbiturates by micellar liquid chromatography

1998

Abstract Studies on the structural requirements of chromatographic surfaces to emulate in vitro the partitioning process in biomembranes are of great interest. The use of micellar mobile phases in RPLC modifies the hydrophobicity of the stationary phase and provides hydrophobic and electrostatic sites of interaction as a consequence of the adsorption of surfactant monomers to the chromatographic surface. Modified stationary phases in MLC could be structurally similar to biomembranes, but thorough studies are necessary to confirm this. In this paper we focus our attention on barbiturates. The influence of the nature and concentration of the surfactant (Brij 35, SDS and CTAB) and the mobile p…

ChromatographyOrganic ChemistryGeneral MedicineReversed-phase chromatographyBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundAdsorptionMonomerPulmonary surfactantchemistryStationary phaseMicellar liquid chromatographyPhase (matter)Journal of Chromatography A
researchProduct

Development of predictive retention-activity relationship models of non-steroidal anti-inflammatory drugs by micellar liquid chromatography: comparis…

2000

The predictive and interpretative capability of quantitative chromatographic retention-biological activity models is supported by the fact that under adequate experimental conditions the solute partitioning into chromatographic system can emulate the solute partitioning into lipid bilayers of biological membranes, which is the basis for drug and metabolite uptake, passive transport across membranes and bioaccumulation. The use of micellar solutions of Brij35 as mobile phases in reversed-phase liquid chromatography has proven to be valid to predict some biological activities of different kinds of drugs. In this study, quantitative retention-activity relationship (QRAR) models to describe som…

ChromatographyPassive transportMetaboliteAnti-Inflammatory Agents Non-SteroidalSynthetic membraneBiological membraneMembranes ArtificialGeneral Chemistrychemistry.chemical_compoundStructure-Activity RelationshipMembranechemistryMicellar liquid chromatographyPredictive Value of TestsMicellar solutionsLipid bilayerChromatography LiquidJournal of chromatography. B, Biomedical sciences and applications
researchProduct

Resolution assessment and performance of several organic modifiers in hybrid micellar liquid chromatography

2001

The performance of four criteria that measure the elementary resolution (modified selectivity, modified RS, peak purity, and orthogonal valley-to-peak ratio) was critically assessed using as global resolution function, the product of elementary measurements. The peak purities and valley-to-peak criteria yielded the best description of the overall separation according to the shape of the resolution surfaces compared to the peak arrangements in the chromatograms, the capability of defining unambiguously the composition regions of complete resolution, and the resolution achieved in the predicted optimums. Peak purities were used to compare the effect of five organic modifiers (1-propanol, 1-bu…

ChromatographyResolution (mass spectrometry)Analytical chemistryPrimary alcoholBiochemistryMicellar electrokinetic chromatographyAnalytical ChemistrySolventchemistry.chemical_compoundchemistryMicellar liquid chromatographyEnvironmental ChemistryAcetonitrileSelectivitySpectroscopyTetrahydrofuranAnalytica Chimica Acta
researchProduct

Determination of water-soluble vitamins in energy and sport drinks by micellar electrokinetic capillary chromatography

2016

Abstract A method for the determination of water-soluble vitamins in several energy and sport drinks by micellar electrokinetic chromatography (MEKC) has been developed in this work. The separation of vitamins was studied in terms of background electrolyte composition (borate content, pH, surfactant type and content) and in other MEKC parameters. A study of the possible compounds found in the vitamin-enriched drinks that could interfere in vitamin determination was also performed, and a modified procedure with enhanced resolution was developed. The proposed method was successfully applied to the analysis of water-soluble vitamins in a variety of energy and sport drinks and also in fruit nec…

ChromatographyResolution (mass spectrometry)Chemistry010401 analytical chemistry04 agricultural and veterinary sciences040401 food science01 natural sciencesMicellar electrokinetic chromatography0104 chemical sciences0404 agricultural biotechnologyPulmonary surfactantReagentWater-Soluble VitaminSample preparationElectrolyte compositionSoft drinkFood ScienceBiotechnologyFood Control
researchProduct