Search results for "centri"
showing 10 items of 869 documents
Background in low Earth orbits measured by LEGRI telescope – short and long term variability
1999
Abstract In this paper we present the first Low Energy Gamma Ray Imager (LEGRI) background measurements which were carried out in the earlier nominal operation activities of LEGRI Instrument on board MINISAT-01, after initial spacecraft and instrument check-up procedures. Short term (daily) and expected long term background variability is presented. A background model is also discussed in order to be used for celestial γ-ray emitters observations.
One-dimensional error-diffusion technique adapted for binarization of rotationally symmetric pupil filters
1995
Abstract Two novel algorithms for the binarization of continuous rotationally symmetric real and positive pupil filters are presented. Both algorithms are based on the one-dimensional error diffusion concept. In our numerical experiment an original gray-tone apodizer is substituted by a set of transparent and opaque concentric annular zones. Depending on the algorithm the resulting binary mask consists of either equal width or equal area zones. The diffractive behavior of binary filters is evaluated. It is shown that the filter with equal width zones gives Fraunhofer diffraction pattern more similar to that of the original gray-tone apodizer than that with equal area zones, assuming in both…
Azimuthally Differential Pion Femtoscopy in Pb-Pb Collisions at sNN=2.76 TeV
2017
We present the first azimuthally differential measurements of the pion source size relative to the second harmonic event plane in Pb-Pb collisions at a center-of-mass energy per nucleon-nucleon pair of √sNN = 2.76 TeV. The measurements have been performed in the centrality range 0%-50% and for pion pair transverse momenta 0.2 < kT < 0.7 GeV/c. We find that the Rside and Rout radii, which characterize the pion source size in the directions perpendicular and parallel to the pion transverse momentum, oscillate out of phase, similar to what was observed at the Relativistic Heavy Ion Collider. The final-state source eccentricity, estimated via Rside oscillations, is found to be significantly sma…
Detecting Eccentricity and Demagnetization Fault of Permanent Magnet Synchronous Generators in Transient State
2019
Eccentricity and demagnetization fault of a four-pole 1.5 kW surface mounted permanent-magnet synchronous-generator (PMSG) were modelled by using time-discretised finite element analysis (FEA). Both fault types are caused by magnetic asymmetry in the generator. The faulty behaviour of a PMSG under transient operating condition is studied with FEA. Two search coils were wound around stator teeth on opposite sides of the rotor. The induced voltage from these coils will be equal in healthy case. A fault is detected when the induced voltages are non-identical. The simulation results revealed that the envelope of the induced search coil voltage had sinusoids during dynamic eccentricity and demag…
Theoretical and experimental behaviour of the muscle viscosity coefficient during maximal concentric actions
1994
The aim of this study was to calculate the theoretical variation of the nonlinear damping factor (B) as a function of the muscle shortening velocity, and then to compare the theoretical values with the experimental data obtained on both the elbow flexor and the ankle extensor muscles. The theoretical variation of the B factor was determined from a muscle model consisting of a contractile component in parallel with a viscous damper both in series with an elastic component, and by using, the characteristic equation of the force velocity curve. In this muscle model, the viscous element modelled the inability of the muscle to generate as big a contracting force (while shortening) as possible un…
The Peregrine breather of order nine and its deformations with sixteen parameters solutions to the NLS equation
2015
Abstract We construct new deformations of the Peregrine breather ( P 9 ) of order 9 with 16 real parameters. With this method, we obtain explicitly new families of quasi-rational solutions to the NLS equation in terms of a product of an exponential depending on t by a ratio of two polynomials of degree 90 in x and t; when all the parameters are equal to 0, we recover the classical P 9 breather. We construct new patterns of different types of rogue waves as triangular configurations of 45 peaks as well as rings and concentric rings.
Tunable liquid lens equipped virtual reality adapter for scientific, medical, and therapeutic goals
2018
We adapted virtual reality appliances to use them in scientific medical diagnostics and therapeutic aims by incorporated as part of appliance ocular system two electrically tunable Optotune liquid lenses, controllable by computer USB ports within 20D range. In present time we used the appliance to investigate the mono- and/or binocularly illusory perception dominances (Shapiro and al;2008), nonlinearities caused by controversial Gestalt recognition of motion. Back layer of stimuli elements contained internal motion sources - clockwise spinning disk on neutral background. Disk consisted of centrosymmetric radial rays which luminance was sinus mode modulated along the disc circumference. Spin…
Red-green vs. blue-yellow spatio-temporal contrast sensitivity across the visual field
2011
We measured contrast sensitivity (CS) to sinusoidal spatio-temporal patterns isolating the red-green and blue-yellow mechanisms, at 21 locations in the visual field (including the fovea). These measurements complete the available data for the red-green mechanism at fovea and for both mechanisms outside fovea with non-stationary patterns. Chromatic detection surfaces are low-pass at fovea and CS decreases with eccentricity at a rate that depends on the spatial and temporal frequencies. Our results confirm that, in general, sensitivities decrease with eccentricity at different rates for stationary red-green and blue-yellow patterns at each point of the spatio-temporal domain and that the chro…
Modelling Demagnetized Permanent Magnet Synchronous Generators using Permeance Network Model with Variable Flux Sources
2019
The partial demagnetization in a four-pole 1.5 kW surface mounted permanent-magnet synchronous-generator was modeled by permeance network model (PNM). The results were compared to a 2-D time-stepping finite element analysis (FEA). Both models where simulated in scenarios where one of the magnets where 20 % and 100 % demagntized and when none of the magnets where demagnetised. The results showed that the proposed PNM with variable magnetic flux sources matched the results of the FEA. The proposed method only need to invers the permeance matrix once before the time simulation, while the traditinal PNM need to invers it in every time step. This make the proposed model less computationally heav…
Force-, power-, and elasticity-velocity relationships in walking, running, and jumping
1980
Ground reaction forces and mechanical power were investigated when the subjects walked normally, while they were racing or running at four speeds, and when they performed the running long jump take-off. In addition, the apparent spring constants of the support leg in eccentric and concentric phases were investigated at the four running speeds, during the running long jump take-off, and in the triple jump. Six club level track and field athletes, four national level long jumpers, and six national level triple jumpers took part in the study. Cinematographic technique and a mathematical model of hopping (Alexander and Vernon 1975) were employed in the analysis. Force and power values were foun…