Search results for "chemical sensor"
showing 10 items of 54 documents
Ascorbic Acid determination using linear sweep voltammetry on flexible electrode modified with gold nanoparticles and reduced graphene oxide
2020
Indium tin oxide (ITO) coated on flexible polyethylene terephthalate (PET) substrate electrode was modified with reduced graphene oxide and gold nanoparticles by simple co-electrodeposition performed at -0.8 V vs SCE for 200 s. All samples were characterized by electron scan microscopy. The as prepared electrode was used as electrochemical sensor to selective detection of ascorbic acid using linear sweep voltammetry. Excellent results were obtained in a linear range from 20 to 150 µM of ascorbic acid with a limit of detection of about 3.1 µM (S/N=3.3). The sensors have a reproducibility of about 5.5% and also show high selectivity towards different interferents such as chlorine, calcium, ma…
Optical Sensor for Real-Time Detection of Trichlorofluoromethane
2019
Trichlorofluoromethane was once a promising and versatile applicable chlorofluorocarbon. Unaware of its ozone-depleting character, for a long time it was globally applied as propellant and refrigerant and thus led to significant thinning of the ozone layer and contributed to the formation of the so-called ozone hole. Although production and application of this substance were gradually reduced at an early stage, we still face the consequences of its former careless use. Today, trichlorofluoromethane is released during recycling processes of waste cooling devices, traded on the black market, and according to recent findings still illegally manufactured. Here, we present an optical sensor devi…
PANI-Based Wearable Electrochemical Sensor for pH Sweat Monitoring
2021
Nowadays, we are assisting in the exceptional growth in research relating to the development of wearable devices for sweat analysis. Sweat is a biofluid that contains useful health information and allows a non-invasive, continuous and comfortable collection. For this reason, it is an excellent biofluid for the detection of different analytes. In this work, electrochemical sensors based on polyaniline thin films deposited on the flexible substrate polyethylene terephthalate coated with indium tin oxide were studied. Polyaniline thin films were abstained by the potentiostatic deposition technique, applying a potential of +2 V vs. SCE for 90 s. To improve the sensor performance, the electronic…
The lower rather than higher density charge carrier determines the NH 3 -sensing nature and sensitivity of ambipolar organic semiconductors
2018
International audience; Despite the extensive studies and great application potentials, the sensing nature of ambipolar organic semiconductor gas sensors still remains unclarified, unlike their inorganic counterparts. Herein, different numbers of thiophenoxy groups are introduced into the phthalocyanine periphery of bis(phthalocyaninato) rare earth semiconductors to continuously tune their HOMO and LUMO energies, resulting in the ambipolar M[Pc(SPh)(8)](2) [M = Eu (1), Ho (2)] and p-type M(Pc)[Pc(SPh)(8)] [M = Eu (3), Ho (4)]. An OFET in combination with direct I-V measurements over the devices from the self-assembled nanostructures of 1-4 revealed the original electron and hole densities (…
Electrochemical Quantification of H2O2 Released by Airway Cells Growing in Different Culture Media
2022
Quantification of oxidative stress is a challenging task that can help in monitoring chronic inflammatory respiratory airway diseases. Different studies can be found in the literature regarding the development of electrochemical sensors for H2O2 in cell culture medium to quantify oxidative stress. However, there are very limited data regarding the impact of the cell culture medium on the electrochemical quantification of H2O2. In this work, we studied the effect of different media (RPMI, MEM, DMEM, Ham’s F12 and BEGM/DMEM) on the electrochemical quantification of H2O2. The used electrode is based on reduced graphene oxide (rGO) and gold nanoparticles (AuNPs) and was obtained by co-electrode…
Optical and electrochemical DNA nanobiosensors
2011
In the past two decades, nanoscale advanced materials have been explored for biosensing molecules, so new horizons have opened up for identifying and quantifying biomolecules, and possible early diagnosis of diseases. DNA nanobiosensors show promise. This article provides an overview on their optical and electrochemical aspects. We discuss recent progress in this field, describing basic concepts of molecular beacons and quantum dots as optical nano-imaging systems. Also, carbon nanotubes provide a platform for development and advancement of electrochemical DNA nanobiosensors, which are increasingly being implemented as robust tools for detection in biomedical sciences. Refereed/Peer-reviewed
Development of a nanostructured sensor for monitoring oxidative stress in living cells
2018
Oxidative burden is elevated in the lung of COPD patients and is associated with aging and chronic inflammation. When overcoming physiological levels, reactive oxygen species (ROS) cause cell damage and sustain inflammation. Both lung epithelium and alveolar macrophages contribute to ROS generation. Currently, ROS generation is measured using fluorescent probes and colorimetric/fluorimetric assays. We present an amperometric nanostructured sensor for real-time detection of hydrogen peroxide (H2O2) released by living cells. The H2O2 sensing performance was evaluated through the current vs time response of platinum rod at a working potential of −0.45 V vs saturated calomel electrode acting as…
Electrochemical sensor based on rGO/Au nanoparticles for monitoring H2O2 released by human macrophages
2021
Abstract Increased oxidative burden contributes to the pathogenesis of most inflammatory diseases and is associated with aging and chronic inflammation. Macrophages contribute to the generation of reactive oxygen species (ROS) within inflamed tissues. Currently, ROS generation is measured using fluorescent probes and colorimetric/fluorimetric biochemical assays. Hydrogen peroxide (H2O2) diffuses through the cell membrane and can be monitored in the extracellular space. Herein, we present a sensor for H2O2 detection released by cells in culture supernatants. H2O2 sensing performance was evaluated using chronoamperometric detection. A sensitivity of 0.0641 μA μM−1 cm−2 with a limit of detecti…
Copper nanowire array as highly selective electrochemical sensor of nitrate ions in water
2020
Contamination of water with nitrate ions is a significant problem that affects many areas of the world. The danger from nitrates is not so much their toxicity, rather low, as their transformation into nitrites and in particular into nitrosamines, substances considered to be a possible carcinogenic risk. For this reason, European legislation has set the maximum permissible concentration of nitrates in drinking water at 44 mg/l. Thus, it is clear that a continuous monitoring of nitrate ions is of high technological interest but it must be rapid, easy to perform and directly performed in situ. Electrochemical detection is certainly among the best techniques to obtain the above requirements. In…
Photoelectrochemical Bisphenol S Sensor Based on ZnO‐Nanoroads Modified by Molecularly Imprinted Polypyrrole
2019
Molecularly imprinted polymers are important tools for the design of sensors and other molecular recognition based analytical systems. In this paper the development of a photoelectrochemical sensor for selective bisphenol determination is reported. The sensor is based on a glass/ZnO/MIP‐Ppy structure consisting of glass modified by a ZnO layer (glass/ZnO), which is functionalized by molecularly imprinted conducting polymer polypyrrole (MIP‐Ppy). The sensitivity of the sensor to bisphenol is in the range of 0.7–12.5 µm. Selectivity tests to other bisphenolic compounds are performed. Some aspects of a photoinduced response mechanism in glass/ZnO/MIP‐Ppy nanostructures are predicte…