Search results for "code"
showing 10 items of 1180 documents
On the search for 50 GeV neutrinos
2000
Using the computer code CompHEP we estimate the number of events and the background, at LEP II and TESLA, for the reaction $e^+ e^- \to N\bar{N}\gamma$, where $N$ is a hypothetical Dirac neutrino with mass of the order of 50 GeV.
Equivalent detector models for the simulation of efficiency response of an HPGe detector with PENELOPE code
2019
In this work, some ‘equivalent’ models for the simulation of efficiency response of a High-Purity Germanium (HPGe) detector, installed inside a ‘low background’ bunker in the Engineering Department of the University of Palermo, were developed. The main feature was to attribute the uncertainties of the model to only one of the parameters, the dead layer of the detector, keeping unchanged the other data provided by the manufacturer. With this technique, using the Monte Carlo PENELOPE code in the 2011 version, the efficiency response was evaluated and compared with the previous one performed with MCNP5 code. The validation of equivalent models is performed by comparing the simulation results w…
The INTEGRAL experiment
1998
The International Gamma-ray Astrophysics Laboratory (INTEGRAL) is conceived as the next logical step in gamma-ray astronomy after the US Compton Gamma-Ray Observatory (CGRO) and the French/Russian SIGMA mission. The INTEGRAL scientific payload consists of two main instruments (Imager and Spectrometer) and two monitor instruments (X-Ray Monitor and Optical Transient Camera). The INTEGRAL spectrometer "SPI" is optimized for detailed measurements of gamma-ray lines and mapping of diffuse sources. It combines a coded aperture mask with an array of large volume, high-purity germanium detectors. The detectors make precise measurements of the gamma-ray energies over the 20 keV-8 MeV energy range. …
A coded mask for γ-ray astronomy. Design and calibration
2003
Abstract The high-resolution γ-ray spectrometer (SPI) is one of the two main instruments on board the ESA INTEGRAL satellite successfully launched in October 2002. SPI uses coded aperture mask technique in order to have imaging capabilities at the energy band (20 keV–8 MeV) it will study celestial sources. The SPI imaging performance depends critically on the quality of the coded mask response and also on the precise knowledge of such response function. In this paper we present a general description of the SPI Coded Mask design together with its main features. Scientific impact of INTEGRAL SPI Coded Mask design on the instrument capabilities is also discussed. Results obtained for Mask cali…
Sensitivity and Efficiency of the INTEGRAL Imager
1995
A detailed simulation program of the INTEGRAL Imager has been written and implemented using the GEANT-3 Monte Carlo code. The expected detection efficiency and continuum sensitivity have been evaluated. The results obtained for the CsI configuration of the Imager are compared with those obtained with the new configuration which foresees a top plane made of CdTe solid state detector elements.
Towards relativistic simulations of magneto-rotational core collapse
2007
We present a new general relativistic hydrodynamics code specifically designed to study magneto-rotational, relativistic, stellar core collapse. The code is an extension of an existing (and thoroughly tested) hydrodynamics code, which has been applied in the recent past to study relativistic rotational core collapse. It is based on the conformally-flat approximation of Einstein's field equations and conservative formulations for the magneto-hydrodynamics equations. As a first step towards magneto-rotational core collapse simulations the code assumes a passive (test) magnetic field. The paper is focused on the description of the technical details of the numerical implementation, with emphasi…
Legri Operations. Detectors and Detector Stability
2001
Two years after launch (04.21.97), LEGRI is operating on Minisat-01 in a LEO orbit. The LEGRI detector plane is formed by two type of gamma-ray solid state detectors: HgI2 and CdZnTe. Detectors are embedded in a box containing the FEE and DFE electronics. This box provides an effective detector passive shielding. Detector plane is multiplexed by a Coded Aperture System located at 54 cm and a Ta Collimator with a FCFOV of 22° and 2° angular resolution. The aim of this paper is to summarize the detector behaviour in three different time scales: before launch, during the in-orbit check-out period (IOC), and after two years of routine operation in space. Main results can be summarized as follow…
Design of a neutron converter for fission studies at the IGISOL facility
2012
The upgraded IGISOL facility with JYFLTRAP, at the accelerator laboratory of the University of Jyvaskyla, has been supplied with a new cyclotron which will provide proton or deuteron beams of the order of 100 μA with up to 30 MeV energy. This makes it an ideal place for measurements of neutron-induced fission fragments from various actinides, in view of proposed future nuclear fuel cycles. In the present paper, some considerations for the design of a neutron converter, based on simulations with the Monte Carlo codes MCNPX and FLUKA, are described.
Approximate quantum error correction for generalized amplitude damping errors
2014
We present analytic estimates of the performances of various approximate quantum error correction schemes for the generalized amplitude damping (GAD) qubit channel. Specifically, we consider both stabilizer and nonadditive quantum codes. The performance of such error-correcting schemes is quantified by means of the entanglement fidelity as a function of the damping probability and the non-zero environmental temperature. The recovery scheme employed throughout our work applies, in principle, to arbitrary quantum codes and is the analogue of the perfect Knill-Laflamme recovery scheme adapted to the approximate quantum error correction framework for the GAD error model. We also analytically re…
Quantum error correction and detection: Quantitative analysis of a coherent-state amplitude-damping code
2013
We re-examine a non-Gaussian quantum error correction code designed to protect optical coherent-state qubits against errors due to an amplitude damping channel. We improve on a previous result [Phys. Rev. A 81, 062344 (2010)] by providing a tighter upper bound on the performance attained when considering realistic assumptions which constrain the operation of the gates employed in the scheme. The quantitative characterization is performed through measures of fidelity and concurrence, the latter obtained by employing the code as an entanglement distillation protocol. We find that, when running the code in fully-deterministic error correction mode, direct transmission can only be beaten for ce…