Search results for "colloids"
showing 9 items of 89 documents
Coarse-Graining Intermolecular Interactions in Dispersions of Highly Charged Colloids
2012
International audience; Effective pair potentials between charged colloids, obtained from Monte Carlo simulations of two single colloids in a closed cell at the primitive model level, are shown to reproduce accurately the structure of aqueous salt-free colloidal dispersions, as determined from full primitive model simulations by Linse et al. (Linse, P.; Lobaskin, V. Electrostatic Attraction and Phase Separation in Solutions of Like-Charged Colloidal Particles. Phys. Rev. Lett.1999, 83, 4208). Excellent agreement is obtained even when ion-ion correlations are important and is in principle not limited to spherical particles, providing a potential route to coarse-grained colloidal interactions…
Synthesis and preliminary in vivo evaluation of well-dispersed biomimetic nanocrystalline apatites labeled with positron emission tomographic imaging…
2015
In recent years, biomimetic synthetic apatite nanoparticles (AP-NPs), having chemical similarity with the mineral phase of bone, have attracted a great interest in nanomedicine as potential drug carriers. To evaluate the therapeutic perspectives of AP-NPs through the mechanisms of action and organs they interact with, the noninvasive monitoring of their in vivo behavior is of paramount importance. To this aim, here the feasibility to radiolabel AP-NPs ("naked" and surface-modified with citrate to reduce their aggregation) with two positron emission tomographic (PET) imaging agents ([F-18]NaF and Ga-68-NO(2)AP(BP)) was investigated. [F-18]NaF was used for the direct incorporation of the radi…
Thermodiffusion motion of electrically charged nanoparticles
2012
AbstractThe present work deals with experimental studies to examine the theoretical model of thermodiffusion of electrically charged nanoparticles. Three different ionic magnetic colloid samples have been synthesized and profoundly analyzed. The theoretical model is a classical one, based on the calculation of the temperature and the electric potential distribution around nanoparticles. The discrepancy between experimental data and theory turns out not to exceed 20%. We focus on applying different approximations between calculated electrical double layer in the theoretical model and experimental determination of the surface charge density of colloidal particles. We assume this is the main r…
Dimensional stability of contemporary irreversible hydrocolloids: humidor versus wet tissue storage.
2012
Statement of problem The storage time and conditions of irreversible hydrocolloid impressions affect their accuracy and in turn the precision of the definitive cast. Recommendations for proper storage are, however, based on theoretical assumptions rather than facts. Purpose The purpose of this study was to assess the influence of the 2 most common storage conditions on the dimensional stability of 7 contemporary irreversible hydrocolloids (IH) for a period of up to 7 days. Material and methods Twelve specimens per material (Blueprint, Cavex CA37, Cavex ColorChange, Jeltrate, Orthoprint, Cavex Orthotrace, and Tetrachrom) were fabricated according to ISO/CD 21563. The specimens were either st…
Sentinel Node Identification in Melanoma: Current Clinical Impact, New Emerging SPECT Radiotracers and Technological Advancements. An Update of the L…
2020
Background: Melanoma is the most lethal skin cancer with a mortality rate of 262 cases per 100.000 cases. The sentinel lymph node (SLN) is the first lymph node draining the tumor. SLN biopsy is a widely accepted procedure in the clinical setting since it provides important prognostic information, which helps patient management, and avoids the side effects of complete lymph node dissection. The rationale of identifying and removing the SLN relies on the low probability of subsequent metastatic nodes in case of a negative histological exam performed in the SLN. Discussion: Recently, new analytical approaches, based on the evaluation of scintigraphic images are also exploring the possibility …
Hyperstoichiometric interaction between silver and mercury at the nanoscale.
2012
Breaking through the stoichiometry barrier: As the diameter of silver particles is decreased below a critical size of 32?nm, the molar ratio of aqueous HgII to Ag0 drastically increases beyond the conventional Hg/Ag ratio of 0.5:1, leading to hyperstoichiometry with a maximum ratio of 1.125:1 (see figure). Therein, around 99?% of the initial silver is retained to rapidly form a solid amalgam with reduced mercury.
Comparison of 99mTc-Labeled Colloid SPECT/CT and Planar Lymphoscintigraphy in Sentinel Lymph Node Detection in Patients with Melanoma: A Meta-Analysis
2020
We compared the detection rate (DR) for sentinel lymph nodes (SLNS), the number of SLNs and the subjects with additional SLNs of single-photon emission computed tomography (SPECT/CT) and planar lymphoscintigraphy (PL) in patients with melanoma. Furthermore, we evaluated the impact of SPECT/CT on surgical plans. Articles containing head-to-head comparisons between SPECT/CT and PL were searched in Pubmed/MEDLINE and Scopus. The literature search was updated until December 31st, 2019. DR was calculated on a per-patient-based analysis; the studies were pooled by their odds ratios (ORs) with a random effects model to assess the significance of difference (p < 0.05). The number of additional S…
Calcium mediated polyelectrolyte adsorption on like-charged surfaces.
2011
International audience; Monte Carlo simulations within the primitive model of calcium-mediated adsorption of linear and comb polyelectrolytes onto like-charged surfaces are described, focusing on the effect of calcium and polyion concentrations as well as on the ion pairing between polymers and calcium ions. We use a combination of Monte Carlo simulations and experimental data from titration and calcium binding to quantify the ion pairing. The polymer adsorption is shown to occur as a result of surface overcharging by Ca2+ and ion pairing between charged monomers and Ca2+. In agreement with experimental observations, the simulations predict that the polymer adsorption isotherm goes through …