Search results for "colorimetry"
showing 10 items of 85 documents
Reversible Colorimetric Probes for Mercury Sensing
2005
The selectivity and sensitivity of two colorimetric sensors based on the ruthenium complexes N719 [bis(2,2'-bipyridyl-4,4'-dicarboxylate)ruthenium(II) bis(tetrabutylammonium) bis(thiocyanate)] and N749 [(2,2':6',2' '-terpyridine-4,4',4' '-tricarboxylate)ruthenium(II) tris(tetrabutylammonium) tris(isothiocyanate)] are described. It was found that mercury ions coordinate reversibly to the sulfur atom of the dyes' NCS groups. This interaction induces a color change in the dyes at submicromolar concentrations of mercury. Furthermore, the color change of these dyes is selective for mercury(II) when compared with other ions such as lead(II), cadmium(II), zinc(II), or iron(II). The detection limit…
In vitro and in vivo characterization of porcine acellular dermal matrix for gingival augmentation procedures
2013
Recently, porcine acellular dermal matrix (PADM) has been proposed as a possible alternative to autogenous grafts in periodontal plastic surgery. The aim of the present study was to investigate the in vitro responses of four different oral cell lines cultured on a novel PADM. Furthermore, tissue reaction to PADM was evaluated histologically after subcutaneous implantation in mice.Human gingival fibroblasts (HGF), human osteoblast-like cells, human umbilical vein endothelial cells and human oral keratinocytes (HOK) were cultured and transferred on to the PADM. A tissue culture polystyrene surface served as the control. The viability of all tested cell lines on PADM was measured by using the …
Clinical efficacy of a bleaching enzyme-based toothpaste. A double-blind controlled clinical trial.
2015
Abstract Objectives To assess the efficacy of a bleaching enzyme-based toothpaste. Material and methods A randomized clinical trial was carried out, comprising 48 participants with teeth exhibiting color A3 or higher according to the Vita Classical guide. One-half of the sample received the bleaching enzyme-based toothpaste (White Kin ® ), while the other received placebo toothpaste. Both products were supplied in identical containers and had the same composition except for the active components. The teeth color was measured with a spectrophotometer. The patients were instructed to brush their teeth three times a day during 3 min with the assigned product, during 12 weeks. The color measure…
Evaluation of an automated chromogenic substrate assay for the rapid determination of hirudin in plasma.
1995
Abstract A fully mechanized chromogenic substrate assay method for the rapid and specific determination of recombinant hirudin (r-hirudin) in citrated plasma on clinical chemistry analyzers (Hitachi 911 and Cobas Mira) is described. In a first step, 12 μl sample volume is mixed with the chromogenic substrate. Due to the almost immediate action of hirudin the inhibitory reaction and the cleavage of the substrate is started simultaneously when bovine thrombin is added in excess. This excludes interferences by antithrombin III or heparin cofactor II. The change in absorbance/min is recorded at 405 nm. The measuring range is about 0.2 – 4.0 mg/l r-hirudin on both analyzers. Precision is charact…
Discriminant ability for caries risk of modified colorimetric tests.
2010
Objetive: The aim of this study was to evaluate the relationship between the caries risk in children over a two-year period and their baseline caries status, salivary levels of mutans streptococci and lactobacilli, and results of the Alban test and modifications thereof using different substrates. Study design: Ninety-five children aged 6-7 were examined in Granada (southern Spain) for dental caries at baseline and every six months. Stimulated saliva was sampled and inoculated in 7 colorimetric tests based on Snyder's medium with different sugars and polyalcohols. A mutans streptococci and lactobacilli count was performed (Dentocult SM strip® and Dentocult LB®). Caries risk proportions were…
A Microassay for Measuring Glycogen in 96-Well-Cultured Cells
1996
Abstract This study describes a rapid, sensitive, and automated spectrophotometric enzymatic microassay that measures the intracellular glycogen of primary cultured hepatocytes and other cultured cells in 96-well plates and can be adapted for other samples that are transferred to these plates. The procedure involves in situ disruption of cells, followed by hydrolysis of glycogen into glucosyl units by fungal glucoamylase (exo-1,4-α- D -glucosidase, EC 3.2.1.3), and glucose determination with the glucose oxidase colorimetric method. The color intensity can be measured in conventional ELISA readers, and the data can be fed to an on-line computer for rapid processing. The advantages of this me…
The accuracy of flexible spectral imaging colour enhancement for the diagnosis of gastric intestinal metaplasia
2014
Background Targeting biopsies on the basis of visual recognition of mucosal changes in the stomach instead of the currently accepted random biopsy sampling may be attractive. Aim The aim of this study was to evaluate the accuracy of endoscopic findings using flexible spectral imaging colour enhancement (FICE) for intestinal metaplasia (IM) in the gastric mucosa. Methods A consecutive cohort of 126 individuals aged over 50 years (27% men) was subjected to upper endoscopy using FICE. Histological assessment (per patient and per biopsy) was considered the gold standard to accuracy estimates. Results Histological assessment revealed IM in 50% of the individuals [OLGIM (operative link on gastric…
A New Environmentally-Friendly Colorimetric Probe for Formaldehyde Gas Detection under Real Conditions
2018
[EN] A new environmentally-friendly, simple, selective and sensitive probe for detecting formaldehyde, based on naturally-occurring compounds, through either colorimetric or fluorescence changes, is described. The probe is able to detect formaldehyde in both solution and the gas phase with limits of detection of 0.24 mM and 0.7 ppm, respectively. The probe has been tested to study formaldehyde emission in contaminated real atmospheres. The supported probe is easy to use and to dispose, and is safe and suitable as an individual chemodosimeter.
Snapshot RGB mapping of skin melanin and hemoglobin.
2015
The concept of snapshot red-green-blue (RGB) multispectral imaging was applied for skin chromophore mapping. Three monochromatic spectral images have been extracted from a single RGB image dataset at simultaneous illumination of skin by 473-, 532-, and 659-nm laser lines. The spectral images were further transformed into distribution maps of skin melanin, oxyhemoglobin, and deoxyhemoglobin, related to pigmented and vascular skin malformations. The performance and clinical potential of the proposed technique are discussed
Ionic-liquid doped polymeric composite as passive colorimetric sensor for meat freshness as a use case.
2020
Abstract A composite membrane containing 1,2-naphthoquinone-4-sulfonic acid sodium salt (NQS) embedded in an ionic liquid (IL)- polydimethylsiloxane (PDMS)- tetraethyl orthosilicate (TEOS)- SiO2 nanoparticles (NPs) polymeric matrix is proposed. The selected IL was 1-methyl-3-octylimidazolium hexafluorophosphate (OMIM PF6). It is demonstrated that ILs chemical additives of PDMS influenced the sol-gel porosity. The sensor analytical performance for ammonia atmospheres has been tested as a function of sampling time (between 0.5 and 312 h), temperature (25 °C and 4 °C) and sampling volume (between 2L and 22 mL) by means of diffuse reflectance measurements and sensor photos, which can be registe…