Search results for "coloring"
showing 10 items of 150 documents
Reliability of Two Color Selection Devices in Matching and Measuring Tooth Color
2011
ABSTRACT Objective The objective of this study was to investigate the intra and interdevice reliability of two tooth color measurement devices: EasyShade (ES) and SpectroShade Micro (SSM). Materials and methods Tooth color was measured in six maxillary and mandibular. L*, a* and b* values and shade matches to VITA Classical and Vitapan 3D-Master shade guide systems were determined for all teeth. ÄE was assessed. Paired t-test and correlation coefficient (ICC) were used. Results Intradevices no significant differences (p > 0.05) were found between L*, a*, b*. Interdevice L* and b* were significantly higher for ES (p < 0.05), while a* was significantly higher for SSM (p < 0.05). ÄE s…
Supravital Methylene Blue Staining of Piloneural Complexes of Common Fur Hair Follicles in the Rat
2000
Light microscopic observations employing supravital methylene blue staining are presented for piloneural complexes of common fur hairs in the mystacial pad of the rat snout. The investigation revealed anatomical details of piloneural complexes belonging to follicles of both vellus and guard hairs. In the methylene blue stained preparations, different types of palisade-like lanceolate nerve fiber endings could be discriminated. The thicker vellus and thinner guard hairs (hair diameter: 15-25 microm) exhibited a different innervation pattern compared to the thicker guard hairs, and two subtypes of piloneural complexes could be distinguished. Both subtypes were characterized by slightly staine…
New aspects in the histological examination of polyethylene wear particles in failed total joint replacements.
2002
The most important long-term complication in total joint replacements is aseptic osteolysis. Wear particles such as polyethylene (PE) debris are considered to be one of the causes that play a central role. Several studies indicated that PE can be visualised in paraffin-embedded tissue sections not only by polarised light, but also after oil red staining. To determine whether oil red staining enables sensitive detection of PE, we examined staining of mechanically-produced PE particles by oil red. Furthermore, we studied oil red staining of paraffin-embedded tissue specimens of patients with failed uncemented and cemented total knee and hip prostheses. We applied double labelling of sections …
Comparison of different quantification methods to determine hippocampal damage after cerebral ischemia
2014
Abstract Background Experimental stroke studies use multiple techniques to evaluate histopathological damage. Unfortunately, sensitivity and reproducibility of these techniques are poorly characterized despite pivotal influence on results. Method The present study compared several quantification methods to differentiate between two severities of global cerebral ischemia and reperfusion. Male Sprague-Dawley rats were randomized to moderate (10 min) or severe (14 min) ischemia by bilateral carotid occlusion (BCAO) with hemorrhagic hypotension. Neuronal cell count was determined in hippocampus at bregma −3.14 mm and −3.8 mm on day 3 and 28 post insult by counting neurons in the whole CA1 or in…
Comparison of three different staining methods for the assessment of epididymal red deer sperm morphometry by computerized analysis with ISAS®
2005
When collection of ejaculated sperm samples is not possible, as is the case with wild species, the epididymides of sacrificed wild males become the only possible source of spermatozoa. Mature cauda epididymal spermatozoa display characteristics similar to those of ejaculated sperm cells. The present work proposes a sperm staining technique suitable for the morphometric evaluation of red deer epididymal sperm using a new computerized system. Epididymides from wild animals were extracted no later than 2 h post mortem. After epididymal sectioning, sperm samples were collected, cooled to and equilibrated at 5 °C, and frozen in liquid nitrogen. Before staining, sperm samples were thawed for 20 s…
Vessel painting of the microcirculation using fluorescent lipophilic tracers
2005
Flexible approaches to defining microvessel morphometry are useful in the study of both acute and chronic structural changes of the microcirculation. In this report, we examined the utility of the intravascular infusion of lipophilic carbocyanine tracers in the structural assessment of the retina, skin, lung, and colon microcirculation. The microvessel labeling technique, here termed fluorescent vessel painting, involved the intravascular injection of sulfonated lipophilic carbocyanine tracers. The utility of vessel painting in morphometry was assessed using morphometric comparisons with corrosion casting and 2-dimensional and 3-dimensional scanning electron microscopy. The comparisons demo…
Chromoendoscopy and narrow-band imaging compared with high-resolution magnification endoscopy in Barrett's esophagus.
2008
Background & Aims: The aim of this study was to compare magnified still images obtained with high-resolution white light endoscopy, indigo carmine chromoendoscopy, acetic acid chromoendoscopy, and narrow-band imaging to determine the best technique for use in Barrett's esophagus. Methods: We obtained magnified images from 22 areas with the 4 aforementioned techniques. Seven endoscopists with no specific expertise in Barretes esophagus or advanced imaging techniques and 5 international experts in this field evaluated these 22 areas for overall image quality, mucosal image quality, and vascular image quality. In addition, the regularity of mucosal and vascular patterns and the presence of abn…
Pathological Evaluation of Mesocolic Resection Quality and Ex Vivo Methylene Blue Injection
2012
BACKGROUND: Although the National Quality Forum has endorsed the harvest of ≥12 lymph nodes as a standard quality indicator for colon cancer surgery, this minimum quantity is not reached in many centers. OBJECTIVE: The aim of this study was to assess the impact of the implementation of a mesocolon evaluation pathological protocol and ex vivo arterial methylene blue injection on the number of nodes harvested after colon cancer resection. DESIGN: A prospective series was compared with a historical group. SETTINGS: This study was conducted by a specialized colorectal multidisciplinary team at a tertiary teaching hospital. PATIENTS: From June 2009 to December 2009, all the specimens after colon…
Energy and charge transfer in nanoscale hybrid materials.
2015
Hybrid materials composed of colloidal semiconductor quantum dots and π-conjugated organic molecules and polymers have attracted continuous interest in recent years, because they may find applications in bio-sensing, photodetection, and photovoltaics. Fundamental processes occurring in these nanohybrids are light absorption and emission as well as energy and/or charge transfer between the components. For future applications it is mandatory to understand, control, and optimize the wide parameter space with respect to chemical assembly and the desired photophysical properties. Accordingly, different approaches to tackle this issue are described here. Simple organic dye molecules (Dye)/quantum…
A fast heuristic for solving the D1EC coloring problem
2010
In this paper we propose an efficient heuristic for solving the Distance-1 Edge Coloring problem (D1EC) for the on-the-fly assignment of orthogonal wireless channels in wireless as soon as a topology change occurs. The coloring algorithm exploits the simulated annealing paradigm, i.e., a generalization of Monte Carlo methods for solving combinatorial problems. We show that the simulated annealing-based coloring converges fast to a sub optimal coloring scheme even for the case of dynamic channel allocation. However, a stateful implementation of the D1EC scheme is needed in order to speed-up the network coloring upon topology changes. In fact, a stateful D1EC reduces the algorithm’s convergen…