Search results for "column"
showing 10 items of 1301 documents
Modelling of FRP and FRCM-Confined Masonry Columns: Critical Review for Design and Intervention Strategies
2022
This paper presents a critical review of the most established analytical models for the prediction of the compressive strength of FRP and FRCM-confined masonry columns. In particular, two types of fibres are analysed, i.e. glass and basalt. A wide dataset available in the literature is used for the application of the analytical models and for the development of parametric analyses useful for the critical comparison of FRP vs. FRCM confinement technique and glass vs. basalt fibres to be adopted as reinforcement of masonry substrate. The effects of stiffness and strength of the reinforcement, the number of reinforcing layers, the compressive strength of masonry and the cross-section shape are…
¿Retorno a las cavernas?
2004
Otro mundo es posible
2001
¿Se acercan los dos Foros?
2002
De la protesta a las propuesta
2002
Elogio de la manifestación
2002
Des luttes locales à la résistance globale
2001
En este texto mecanografiado se indica que se trata de un editorial para el "Bulletin des Amis de Le Monde Diplomatique" (mayo de 2001), pero no se ha encontrado la versión publicada.
mHealth for the Monitoring of Brace Compliance and Wellbeing in Adolescents with Idiopathic Scoliosis: Study Protocol for a Feasibility Study
2021
Escoliosis idiopática del adolescente; Aplicación móvil; Eficacia del tratamiento Escoliosi idiopàtica de l'adolescent; Aplicació mòbil; Eficàcia del tractament Adolescent idiopathic scoliosis; Mobile application; Treatment effectiveness Attempts to optimize monitoring of brace adherence prescribed to adolescents with idiopathic scoliosis (IS) have generally relied on sensors. Sensors, however, are intrusive and do not allow the assessment of psychological and physical consequences of brace use that might underlie poor adherence. Mobile applications have emerged as alternatives to monitor brace compliance. However, the feasibility and utility of these app-based systems to assess key psychol…
Contrasting probabilistic and anti-optimization approaches in an applied mechanics problem
2003
Probabilistic and non-probabilistic, anti-optimization analyses of uncertainty are contrasted in this study. Specifically, the comparison of these two competing approaches is conducted for an uniform column, with initial geometric imperfection, subjected to an impact axial load. The reliability of the column is derived for the cases when the initial imperfections posses either (a) uniform probability density, (b) truncated exponential density or (c) generic truncated probability density. The problem is also analyzed in the context of an interval analysis. It is shown that in, the most important near-unity reliability range these two approaches tend to each other. Since the interval analysis…
Gas-liquid chromatographic analyses
1983
Abstract The gas chromatography of mixtures of n -alkyl acetates (CH 3 COOR, R = C 1 —C 8 ) and methyl esters of aliphatic n -carboxylic acids (R′COOCH 3 , R′ = C 1 —C 8 ) and certain of their monochlorinated derivatives has been studied on Carbowax 20M and SE-30 glass capillary columns under the same operating conditions. The separation of the isomeric monochlorinated esters was complete on Carbowax 20M, whereas on SE-30 the peaks of 6- and 7-chlorooctyl acetates and methyl (ω − 1)- and (ω − 2)-chlorooctanoates and -nonanoates partly overlapped. The complete separation of the mixtures could not be achieved, however, on Carbowax 20M, in spite of the use of various operating conditions. The …