Search results for "computed tomography"
showing 10 items of 713 documents
Imaging features of pancreatic metastases: A comparison with pancreatic ductal adenocarcinoma
2018
Purpose: To compare imaging features of pancreatic metastases (PM) with those of pancreatic ductal adenocarcinomas (PDAC). Methods: CT and MR scans of 24 patients with 54 PM and 30 patients with PDAC were reviewed to evaluate the imaging features, which were compared by using a Chi square test. Results: We found a statistically significant difference between PM and PDAC based on location (P < 0.001), margins (P < 0.001), arterial enhancement (P = 0.004), rim enhancement (P < 0.001), pancreatic duct dilatation (P = 0.01), common bile duct dilatation (P = 0.003), vascular involvement (P = 0.02), parenchymal atrophy (P < 0.001), peripancreatic fluid (P = 0.03). Conclusion: Imaging features mig…
Perfusion computed tomography of intracranial meningiomas: In vivo correlation of cerebral blood volume and vascular permeability
2015
Background A noninvasive method to predict the grade of a meningioma would be desirable since it would anticipate information about tumour nature, recurrence and improve tumour management and outcomes. The aim of the present study was to assess the ability of perfusion computed tomography (PCT) technique in predicting the meningioma grade before surgery. Data from PCT, such as cerebral blood volume (CBV) and permeability surface (PS), were correlated with immunohistolopathological information. Methods Twenty-three patients with a diagnosis of intracranial meningioma underwent PCT for pre-surgical evaluation of CBV and PS. During surgery, samples from the centre and periphery of the tumour w…
Digital Tomosynthesis: A New Technique for Imaging Nephrolithiasis. Specific Organ Doses and Effective Doses Compared With Renal Stone Protocol Nonco…
2014
Objective To determine organ-specific doses (ODs) and effective dose (ED) for digital tomosynthesis (DT) and compare it with our institutional renal stone protocol noncontrast computed tomography (NCCT). Methods A validated anthropomorphic male phantom was placed supine on a digital GE Definium 8000 radiological scanner. Thermoluminescent dosimeters were placed in 256 locations and used to measure OD. A routine DT study was performed consisting of 2 scout images and 1 tomographic sweep in a 14.2-degree arc over the phantom. Software is used to recreate a series of coronal images from the sweep. ODs were determined as the sum of the doses for the study. Equivalent doses were calculated by mu…
Impact of structured report on the quality of preoperative CT staging of pancreatic ductal adenocarcinoma: assessment of intra- and inter-reader vari…
2019
Purpose: To evaluate whether a structured radiology report improves the completeness of preoperative CT staging of pancreatic ductal adenocarcinoma (PDA) compared to conventional free-text reports. Methods: We retrospectively included 27 patients (mean age, 64 ± 11.1 years) referred for pancreatic preoperative CT scan for staging of PDA between 2015 and 2018 and in whom a diagnosis of pancreatic adenocarcinoma was ultimately confirmed. Four readers independently reported CT scans with both conventional free-text and structured reports. Differences in reported morphologic and vascular features with the two reports were assessed through McNemar Test. Intra-reader and inter-reader were calcula…
Three-Dimensional Analysis of Component Stability of the Nellix Endovascular Aneurysm Sealing System After Treatment of Infrarenal Abdominal Aortic A…
2016
Purpose: To assess short-term stability and conformational changes of the Nellix EndoVascular Aneurysm Sealing (EVAS) System using 3-dimensional (3D) analysis. Methods: Postoperative computed tomography (CT) scans obtained at 0, 3, and 12 months in 24 patients (mean age 75±7 years; 22 men) who underwent EVAS between December 2013 and December 2014 for intact abdominal aortic aneurysm (within the instructions for use) were evaluated for stent-graft deviation in multiple planes using dedicated 3D analysis software. In addition, 2D analysis using an anatomically fixed reference landmark was performed to assess craniocaudal migration. Clinical and follow-up data of the patients were recorded a…
Diagnosis of silent coronary ischemia with selective coronary revascularization might improve 2-year survival of patients with critical limb-threaten…
2021
Abstract Background Patients with critical limb-threatening ischemia (CLTI) have had poor long-term survival after lower extremity revascularization owing to coexistent coronary artery disease. A new cardiac diagnostic test, coronary computed tomography-derived fractional flow reserve (FFRCT), can identify patients with ischemia-producing coronary stenosis who might benefit from coronary revascularization. We sought to determine whether the diagnosis of silent coronary ischemia before limb salvage surgery with selective postoperative coronary revascularization can reduce the incidence of adverse cardiac events and improve the survival of patients with CLTI compared with standard care. Metho…
Treating iliac aneurysm using the Nellix Endovascular Sac Sealing System.
2016
As endovascular treatment of abdominal aortic aneurysms has become established, there has been growing focus on treatment of the aneurysmal iliac artery. Isolated, large iliac aneurysms >30 mm pose a risk of rupture, but, in addition, 20% to 30% of abdominal aortic aneurysms are associated with iliac aneurysmal dilatation, which can compromise long-term outcomes. Endovascular solutions are evolving and until recently have utilized standard stent graft technology. The endovascular aortic sealing system was introduced as a new, effective method for the treatment of infrarenal aortic aneurysms. In this article, we present our recent extended use of the Nellix system, with or without a combinat…
Pre-operative Diagnosis of Silent Coronary Ischaemia May Reduce Post-operative Death and Myocardial Infarction and Improve Survival of Patients Under…
2019
Objective Patients undergoing peripheral vascular surgery have increased risk of death and myocardial infarction (MI), which may be due to unsuspected (silent) coronary ischaemia. The aim was to determine whether pre-operative diagnosis of silent ischaemia using coronary computed tomography (CT) derived fractional flow reserve (FFRCT) can facilitate multidisciplinary care to reduce post-operative death and MI, and improve survival. Methods This was a single centre prospective study with historic controls. Patients with no cardiac symptoms undergoing lower extremity surgical revascularisation with pre-operative coronary CTA-FFRCT testing were compared with historic controls with standard pre…
Use of covered chimney stents for pararenal aortic pathologies is safe and feasible with excellent patency and low incidence of endoleaks.
2012
Background To present the clinical experience of consecutive series with use of balloon-expandable and self-expanding chimney endografts (balloon-expandable covered stent group [BECS] vs self-expanding covered stent group [SECS]) in the endovascular treatment of challenging aortic pathologies requiring renal and/or visceral revascularization. Methods Between January 2009 and May 2011, data for 37 high-risk patients from one center and 35 patients from another institution, with pararenal aortic pathologies treated by the chimney endovascular technique, were prospectively collected. The chimney-graft technique is based on the deployment of a covered or bare-metal stent parallel to the aortic …
The DETOUR procedure: no more need for conventional bypass surgery?
2018
Background Long segment occlusive disease in the superficial femoral artery remains a treatment challenge despite advances in open surgical and endovascular approaches. We report initial clinical results of an entirely new procedure to perform percutaneous femoro-popliteal bypass using the DETOUR System. First-in-human patients were performed in New Zealand from December 2013 to June 2014. After modifications to the technique and devices had significantly refined the procedure, the Detour I Trial commenced. Methods Review of initial results in the first five patients treated at a single site enrolled in IRB-approved, prospective clinical study using the DETOUR System. All patients signed in…