Search results for "contact lens"

showing 10 items of 119 documents

Visual performance with simultaneous vision multifocal contact lenses.

2011

Purpose:  The aim was to assess visual performance after PureVision high addition multifocal contact lens (PM) fitting through contrast sensitivity measured under different illumination levels for both distance and near. Methods:  In a cross-over study, 20 presbyopic patients were randomly assigned to PM or spectacles. Near contrast sensitivity was measured with the Vistech VCTS 6500 system. Distance contrast sensitivity and distance visual acuity (VA) were measured with the Functional Vision Analyser under photopic (85 cd/m2) and mesopic (3.0 cd/m2) conditions, the latter also under two levels of induced glare: 1.0 lux and 28 lux. Near VA was measured by logMAR charts under approximately 8…

Adultmedicine.medical_specialtyDistance visual acuitygenetic structuresMesopic visionContact Lensesmedia_common.quotation_subjectVisual AcuityContrast SensitivityOpticsOphthalmologymedicineContrast (vision)Humansmedia_commonMathematicsMonocularCross-Over Studiesbusiness.industryGlare (vision)Accommodation OcularPresbyopiaEquipment DesignPresbyopiaMiddle Agedmedicine.diseaseeye diseasesContact lensOphthalmologyTreatment OutcomebusinessOptometryPhotopic visionFollow-Up StudiesClinicalexperimental optometry
researchProduct

Biocompatible hydrogels based on hyaluronic acid cross-linked with a polyaspartamide derivative as delivery systems for epithelial limbal cells.

2011

The aim of this work was to evaluate the potential use of hydrogels based on hyaluronic acid (HA) chemically cross-linked with α,β-poly(N-2-hydroxyethyl) (2-aminoethylcarbamate)-D,L-aspartamide (PHEA-EDA) as substitutes for the amniotic membrane able to release limbal cells for corneal regeneration. Hydrogels, shaped as films, with three different molar ratios (X) between PHEA-EDA and HA (X = 0.5, 1.0 and 1.5) have been investigated. First, it has been evaluated their swelling ability, hydrolytic resistance in simulated physiological fluid and cell compatibility by using human dermal fibroblasts chosen as a model cell line. Then adhesion studies in comparison with collagen gel, have been pe…

Cell SurvivalContact LensesDrug CompoundingCellPharmaceutical ScienceCell LineGlycosaminoglycanchemistry.chemical_compoundDrug Delivery SystemsHyaluronic acidPolymer chemistrymedicineCell AdhesionPolyaminesAnimalsHumansAmnionHyaluronic AcidCell adhesionAspartameEpithelial CellsHydrogelsFibroblastsIn vitroCoculture Techniquesmedicine.anatomical_structurechemistryCell cultureSelf-healing hydrogelsBiophysicssense organsCollagenRabbitsImmortalised cell lineInternational journal of pharmaceutics
researchProduct

Perfiles de potencia de las lentes de contacto medidas con NIMO TR1504

2017

This study was supported by the Ministerio de Economía y Competitividad and FEDER (Grant DPI2015-71256-R) and by the Generalitat Valenciana (Grant PROMETEOII-2014-072), Spain.

Contact LensesComputer sciencebusiness.industryRefraction OcularRefraction03 medical and health sciencesOcular physiology0302 clinical medicineOpticslcsh:Ophthalmologylcsh:RE1-994FISICA APLICADA030221 ophthalmology & optometryHumanslcsh:QC350-467businessScientific LetterAlgorithmsSoftware030217 neurology & neurosurgerylcsh:Optics. LightOptometry
researchProduct

Repeatability of in vitro power profile measurements for multifocal contact lenses

2015

Abstract Purpose To evaluate the repeatability of an optical device (NIMO TR1504, Lambda-X, Belgium) for measuring multifocal contact lens power profiles. Methods The NIMO TR1504 was used to measure power profiles 30 times for each of 10 different contact lenses from 4 major companies. All contact lenses were labelled as −3 D for distance vision; half were for high addition and half for low addition. The optical zone in all measurements was set to 3-mm radius. For each lens, the median power profile and the residuals of the 30 measurements were calculated. The 95% confidence bands and two indices that summarize measurement errors were calculated: the repeatability limit and an index of repe…

Contact lens powerObservational errorMaterials sciencegenetic structuresContact Lensesbusiness.industryReproducibility of ResultsEquipment DesignGeneral MedicineRepeatabilityRadiusRefraction OcularRefractive Errorseye diseaseslaw.inventionPower (physics)Lens (optics)OphthalmologyOpticslawHomogeneousHumanssense organsbusinessOptometryContact Lens and Anterior Eye
researchProduct

Antibacterial and antifungal effects of soft contact lens disinfection solutions.

1998

To study the antibacterial and antifungal effects of soft contact lens disinfection solutions.Eight contact lens disinfection solutions containing hydrogen peroxide or biguanides or polyquad compounds were evaluated with respect to their ability to disinfect a saline solution experimentally contaminated with different bacteria and with a fungus. We used cultures in blood Agar, MuellerHinton agar and Saboureaud's agar to identify the bacterial and fungal growth following 14 h of exposure to the disinfection solutions.Hydrogen peroxide, DYMED and polyhexamide solutions prevented the growth of the four bacteria studied. The solution containing biguanide prevented the growth of Escherichia coli…

Contact lensAntifungalOphthalmologymedicine.medical_specialtybusiness.industrymedicine.drug_classOcular InfectionsMedicineDentistryGeneral MedicinebusinessOptometrySurgeryContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

pH of multipurpose contact lens solutions over time

1998

The pH of nine different brands of multipurpose contact lens solutions available in Spain was determined over a period of 32 days after opening the bottles. Five bottles of nine solutions were used, each of which was buffered and obtained from different manufacturers. The pH measurements were taken using a micropH 2002 Crison pH-meter (accuracy +/- 0.001 pH units). Each solution was measured three times daily over the test period using 10-ml samples taken from the same container. Fluctuations in pH over time were observed but these were within the range of ocular comfort. The average pH of all the solutions tested proved to be between 6.99 and 7.56.

Contact lensOphthalmologyContact lens solutionsChromatographyMaterials scienceGeneral MedicinePh measurementOptometryBiomedical engineeringContact Lens and Anterior Eye
researchProduct

Comparative study of pH for different saline and multi-purpose contact lens solutions.

1997

In this study, we determined the pH of different saline and multipurpose contact lens solutions available on the Spanish market. We examined 10 samples of 14 solutions, seven of which are saline solutions and seven multipurpose ones, from different manufacturers. Both types of solution were found to have significant variations in pH, with values ranging from 6.70 to 7.57 for the saline solutions and 6.84 to 7.63 for the multipurpose solutions. We concluded that the solutions should not affect the ocular physiological performance because their pH values are within the buffering capacity of the eye.

Contact lensOphthalmologyContact lens solutionsChromatographySaline solutionsChemistrymedicine.medical_treatmentmedicineGeneral MedicineSalineOptometryContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

The impact of daily disposable soft contact lens wear on tear film surface quality over a three month period

2017

Contact lensOphthalmologymedicine.medical_specialtybusiness.industrymedicineDentistryDaily disposableGeneral MedicinebusinessSurgeryActa Ophthalmologica
researchProduct

“In situ” corneal and contact lens thickness changes with high resolution OCT

2012

Purpose: To show the utility of high resolution spectral domain optical coherence tomography (HR SOCT) for the in situ evaluation of epithelial, stromal and contact lens (CL) thickness changes under closed-eye conditions without lens removal. Settings: Clinical and Experimental Optometry Research Lab, University of Minho, Portugal. Methods: Eight young healthy patients wore a thick soft CL during 90 minutes under closed-eye conditions and measures of epithelial and stromal corneal thickness were obtained at regular intervals using a HR SOCT (Copernicus HR, Optopol Tech. SA, Poland). Results: Minimal changes in epithelial thickness were detected with a transient statistically significant inc…

Corneacontact lensesScience & Technologygenetic structuresOCTepithelial thicknessCoherence tomographysense organsedemaeye diseasesstromal thickness
researchProduct

Corneal aberrations pre and post-application of new contact lens in the astigmatism after penetrating keratoplasty.

2007

Corneal aberrations new contact lens keratoplasty.
researchProduct