Search results for "cooling"
showing 10 items of 470 documents
Correlation of primary and secondary relaxations in a supercooled liquid
2006
The widespread assumption that primary and secondary relaxations in glass-forming materials are independent processes is scrutinized using spin-lattice relaxation weighted stimulated-echo spectroscopy. This nuclear magnetic resonance (NMR) technique is simultaneously sensitive to the dynamics on well-separated time scales. For the deeply supercooled liquid sorbitol, which exhibits a strong secondary relaxation, the primary relaxation (that is observable using NMR) can be modified by suppressing the contributions of those subensembles which are characterized by relatively slow secondary relaxations. This is clear evidence for a correlation between primary and secondary relaxation times. In t…
The effects of cryogenic cooling on surface integrity in hard machining: A comparison with dry machining
2012
Eurofusion-DEMO Divertor - Cassette Design and Integration
2020
International audience; The Eurofusion-DEMO design will complete the Pre Conceptual Design phase (PCD) with a PCD Gate, named G1, scheduled to take place in Q4 2020 that will focus on assessing the feasibility of the plant and its main components prior to entering into the Conceptual Design phase. In the paper first an overview is given of the Eurofusion-DEMO Divertor Assembly including design and interface description, systems and functional requirements, load specification, system classification, manufacturing procedures and cost estimate. Then critical issues are discussed and potential design solutions are proposed, e.g.:- Neutron material damage limits of the different (structural) mat…
Design, construction and cooling system performance of a prototype cryogenic stopping cell for the Super-FRS at FAIR
2015
A cryogenic stopping cell for stopping energetic radioactive ions and extracting them as a low energy beam was developed. This first ever cryogenically operated stopping cell serves as prototype device for the Low-Energy Branch of the Super-FRS at FAIR. The cell has a stopping volume that is 1 m long and 25 cm in diameter. Ions are guided by a DC field along the length of the stopping cell and by a combined RF and DC fields provided by an RE carpet at the exit-hole side. The ultra-high purity of the stopping gas required for optimum ion survival is reached by cryogenic operation. The design considerations and construction of the cryogenic stopping cell, as well as some performance character…
Energy performance improvements of a DEC system due to wet heat exchangers
2011
This work concerns an innovative desiccant and evaporative cooling (DEC) system for building air conditioning. The original system is an experimental DEC air handling unit installed at the Solar Laboratory of the University of Palermo and recently modified and updated. With the aim to increase the cooling effect due to water evaporation in the return air flow rate, the sensible heat exchanger was replaced with two cross flow flat plate heat exchangers installed in series, with continuous humidification of the secondary air flow. The new thermodynamic cycle is theoretically described and the realization of the real application is shown. Detailed operational data and energy performance indica…
Odesse: A New Tool for Simulation and Design of Solar Desiccant Cooling Systems in Energy Efficient Buildings
2010
Simplified models for the performance evaluation of desiccant wheel dehumidification
2002
In the present communication, simple models have been presented to evaluate the performance of rotary desiccant wheels based on different kind of solid desiccants e.g. silica gel and LiCl. The first part of the paper presents ‘Model 54’ which is developed for silica gel desiccant rotor. The model has been derived from the interpolation of experimental data obtained from the industry and the correlations have been developed for predicting outlet temperature and absolute humidity. The ‘Model 54’ consists of 54 coefficients corresponding to each correlation for outlet absolute humidity and temperature and it is found that the model predicts very well the performance of silica gel desiccant rot…
Experimental results on adsorption beds for air dehumidification
2016
Desiccant rotors are commonly used in large scale solar cooling open cycle applications. As is well known, adsorption heat sensibly reduces the dehumidification capacity of the desiccant material and results in lower system performance. The aim of this work is to describe an innovative solution that permits simultaneous mass and heat transfer. In particular, two components working with silica gel fixed beds were studied and compared. The first component is a simple packed bed containing silica gel grains. The second component is a fin and tube heat exchanger commonly used in several air conditioning applications wherein the spaces between the fins are filled with silica gel grains. In this …
ADVANCED SOLAR ASSISTED DESICCANT AND EVAPORATIVE COOLING SYSTEM EQUIPPED WITH WET HEAT EXCHANGERS
2011
Abstract This work concerns an innovative solar assisted desiccant and evaporative cooling (DEC) system for building air conditioning. In this system, air-to-air packaged wet heat exchangers are used to maximize the exploitation of the evaporative cooling potential associated with the exhaust air stream. The thermodynamic cycle is first theoretically described, and then an example of a real application is shown. The system presented is an experimental DEC system originally installed at the beginning of 2008 at the Solar Laboratory of the University of Palermo and recently modified and updated. These modifications have been implemented with the aim to foster some problems related to the conv…
Search for Subsolar Mass Ultracompact Binaries in Advanced LIGO's Second Observing Run
2019
We present a search for subsolar mass ultracompact objects in data obtained during Advanced LIGO’s second observing run. In contrast to a previous search of Advanced LIGO data from the first observing run, this search includes the effects of component spin on the gravitational waveform. We identify no viable gravitational-wave candidates consistent with subsolar mass ultracompact binaries with at least one component between \ud0.2\ud \ud \udM\ud⊙\ud–\ud1.0\ud \ud \udM\ud⊙\ud. We use the null result to constrain the binary merger rate of (\ud0.2\ud \ud \udM\ud⊙\ud, \ud0.2\ud \ud \udM\ud⊙\ud) binaries to be less than \ud3.7\ud×\ud10\ud5\ud \ud \udGpc\ud−\ud3\ud \udyr\ud−\ud1\udand the binary …