Search results for "cooling"
showing 10 items of 470 documents
Improving energy efficiency of commercial buildings by Combined Heat Cooling and Power plants
2020
Abstract Commercial buildings play a key-role in the energy consumption of the building sectors. Recent statistics have shown that as the number of commercial buildings is continuously increasing, their effects on energy consumption are expected to grow. These buildings are characterized by high energy demand mainly due to lighting and HVAC requirements. Rooms of energy saving exist by considering that: (i) electricity demands and HVAC requirements occur simultaneously during the day and (ii) both demands are currently satisfied by using separate energy systems. It is apparent that the adoption of polygeneration systems could represent a valid solution to achieve energy savings. To this aim…
Energy Efficiency and Sustainability of Different Building Structures in Latvian Climate
2015
Five experimental test buildings have been built in Riga, Latvia. They are identical except external walls for which different mainly regional building materials are used. Calculated U-values of the other walls, floor and ceiling are the same for each test building. Initial moisture influences the relative humidity of indoor air, which can be higher in the initial time period; as a result, heat transmittances are also very different and cause different heating/cooling energy consumption. Overheating risk in summer exists for test buildings with the smallest thermal inertia. Both summer and heating seasons have been analysed and differences between five test houses have been discussed in det…
Theories of the Structural Glass Transition
2005
The Global Stratotype Section and Point (GSSP) of the Serravallian Stage (Middle Miocene)
2009
The Global Stratotype Section and Point (GSSP) for the Base of the Serravallian Stage (Middle Miocene) is defined in the Ras il Pellegrin section located in the coastal cliffs along the Fomm Ir-Rih Bay on the west coast of Malta (35°54'50"N, 14°20'10"E). The GSSP is at the base of the Blue Clay Formation (i.e., top of the transitional bed of the uppermost Globigerina Limestone). This boundary between the Langhian and Serravallian stages coincides with the end of the major Mi-3b global cooling step in the oxygen isotopes and reflects a major increase in Antarctic ice volume, marking the end of the Middle Miocene climate transition and the Earth's transformation into an "Icehouse" climate sta…
Solar heating and cooling systems versus conventional systems assisted by photovoltaic: Application of a simplified LCA tool
2016
Abstract Life Cycle Assessment (LCA) is an effective methodology to assess the energy and environmental impacts of energy systems during their life cycle, including manufacturing, operation and end-of-life. The aim of the paper is the application of a simplified LCA tool, developed in the framework of the International Energy Agency Solar Heating and Cooling Task 48, for comparing different typologies of solar assisted heating and cooling systems. In detail, solar thermal heating and cooling systems located in Palermo (southern Italy) and in Zurich (Switzerland) were compared with conventional systems assisted by grid connected and stand-alone photovoltaic plants. A validation of the tool w…
GFP-mut2 Proteins in Trehalose-Water Matrixes: Spatially Heterogeneous Protein-Water-Sugar Structures
2007
We report investigations on the properties of nanoenvironments around single-GFP-mut2 proteins in trehalose-water matrixes. Single-GFPmut2 molecules embedded in thin trehalose-water films were characterized in terms of their fluorescence brightness, bleaching dynamics, excited state lifetime, and fluorescence polarization. For each property, sets of approximately 100-150 single molecules have been investigated as a function of trehalose content and hydration. Three distinct and interconverting families of proteins have been found which differ widely in terms of bleaching dynamics, brightness, and fluorescence polarization, whose relative populations sizably depend on sample hydration. The r…
Efficiency improvement of a ground coupled heat pump system from energy management
2011
The installed capacity of an air conditioning system is usually higher than the average cooling or heating demand along the year. So, most of the time, the system is working under its actual capacity. In this contribution, we study the way to improve the efficiency of a ground coupled heat pump air conditioning system by adapting its produced thermal energy to the actual thermal demand. For this purpose, an air conditioning system composed by a ground coupled heat pump and a central fan coil linked to an office located in a cooling dominated area was simulated, and a new management strategy aiming to diminish electrical consumption was developed under the basic constraint that comfort requi…
On the observability of T Tauri accretion shocks in the X-ray band
2010
Context. High resolution X-ray observations of classical T Tauri stars (CTTSs) show a soft X-ray excess due to high density plasma (n_e=10^11-10^13 cm^-3). This emission has been attributed to shock-heated accreting material impacting onto the stellar surface. Aims. We investigate the observability of the shock-heated accreting material in the X-ray band as a function of the accretion stream properties (velocity, density, and metal abundance) in the case of plasma-beta<<1 in the post-shock zone. Methods. We use a 1-D hydrodynamic model describing the impact of an accretion stream onto the chromosphere, including the effects of radiative cooling, gravity and thermal conduction. We expl…
Observability and diagnostics in the X-ray band of shock-cloud interactions in supernova remnants
2010
X-ray emitting features originating from the interaction of supernova shock waves with small interstellar gas clouds are revealed in many X-ray observations of evolved supernova remnants (e.g. Cygnus Loop and Vela), but their interpretation is not straightforward. We develop a self-consistent method for the analysis and interpretation of shock-cloud interactions in middle-aged supernova remnants, which can provide the key parameters of the system and the role of relevant physical effects like the thermal conduction, without the need to run ad-hoc numerical simulations and to bother of morphology details. We explore all the possible values of the shock speed and cloud density contrast releva…
Numerical evaluation on performances of AHU equipped with a cross flow heat exchanger in wet and dry operation
2012
Abstract In this paper the comparison between the performance of a cross flow heat exchanger in wet and dry operation for air handling process has been investigated. In addition, a case study of application of the component to perform indirect evaporative cooling in a AHU was studied with the software TRNSYS.Using experimental data and an appropriate analytical method, energy saving performances of the system has been evaluated through the entire cooling season for a typical Mediterranean site. Results show that high energy saving potential can be obtained if the component is operated in wet operation in term of reduction of electricity consumption.