Search results for "corn"

showing 10 items of 710 documents

Circumscribed palmar or plantar hypokeratosis: a distinctive epidermal malformation of the palms or soles.

2002

Abstract Background: Epidermal malformations of the skin include a group of heterogeneous developmental defects that result from errors in morphogenesis of the epidermis during intrauterine life. Objective: The purpose of this study was to report the clinical and histopathologic features of a distinctive epidermal malformation involving the skin of the palms or soles. Methods: Ten patients were included in this study. All of them showed the same clinical features that consisted of a solitary circumscribed and circular area of erythematous depressed skin on the palm or on the sole. Diagnosis was confirmed by histopathologic study. Results: All patients were middle aged or elderly. Nine patie…

AdultMalePathologymedicine.medical_specialtyKeratosisBowen's DiseaseDermatologySeverity of Illness IndexSampling StudiesLesionDiagnosis DifferentialKeratoderma PalmoplantarmedicineHumansProspective StudiesKeratodermaAgedBowen's diseaseCorneocyteintegumentary systembusiness.industryBiopsy NeedleAnatomyMiddle Agedmedicine.diseaseImmunohistochemistryPorokeratosismedicine.anatomical_structureFemaleEpidermismedicine.symptomDifferential diagnosisEpidermisbusinessPorokeratosisJournal of the American Academy of Dermatology
researchProduct

The early clinical phenotype of Fabry disease: a study on 35 European children and adolescents.

2003

Fabry disease (FD) is a debilitating progressive multisystem X-linked lysosomal storage disorder. It was generally believed that the disease affects only adult males. Through systematic pedigree analysis, we identified 35 paediatric FD patients (age 1 to 21 years, mean 12.6 years) in 25 families. Predominant signs in this cohort were: acroparesthesia, hypohidrosis, and cornea verticillata. Neurological and psychological changes, such as tinnitus, recurrent vertigo, headache, diminished level of activity, fatigue, and depression were often observed. Angiokeratoma and gastrointestinal symptoms were frequent. Some patients also showed cardiac abnormalities. Six children and adolescents (three …

AdultMalePediatricsmedicine.medical_specialtyAdolescentDiseaseRisk AssessmentSeverity of Illness IndexCohort StudiesAge DistributionSeverity of illnessmedicineHumansCornea verticillataGenetic Predisposition to DiseaseSex DistributionChildDepression (differential diagnoses)business.industryIncidenceEnzyme replacement therapymedicine.diseasePrognosisFabry diseaseHealth SurveysAngiokeratomaSurgeryEuropePhenotypeChild PreschoolPediatrics Perinatology and Child HealthFabry DiseaseFemalemedicine.symptombusinessCohort studyEuropean journal of pediatrics
researchProduct

Iris-fixated toric phakic intraocular lens for myopic astigmatism

2011

Purpose To evaluate the efficacy, predictability, safety, stability, and complications of the Artiflex toric iris-fixated phakic intraocular lens (pIOL) for myopic astigmatism. Setting Private practice surgery centers, Valencia and Terrassa, Spain. Design Cohort study. Methods At 12 months, refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, complications, pIOL misalignment, and endothelial cell count (ECC) were evaluated. Indices of success and misalignment were calculated using vector analysis. Results The study enrolled 42 eyes in 25 patients aged 21 to 39 years. The mean spherical equivalent decreased from −8.85 diopters (D) ± 2.71 (SD) to −0.37 ± 0.46 D, with …

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyVisual acuitygenetic structuresVisual AcuityIrisAstigmatismRefraction OcularPhakic intraocular lensCohort StudiesMyopic astigmatismYoung AdultPostoperative ComplicationsLens Implantation IntraocularOphthalmologyMyopiamedicineHumansIris (anatomy)Dioptremedicine.diagnostic_testbusiness.industrySuture TechniquesAstigmatismCorneal TopographyCorneal topographymedicine.diseaseeye diseasesSensory SystemsOphthalmologyTreatment Outcomemedicine.anatomical_structurePrivate practiceFemaleSurgerymedicine.symptombusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

On-eye optical quality of daily disposable contact lenses for different wearing times

2012

Purpose To quantify the optical quality of various daily disposable contact lenses in vivo and to ascertain its variation in terms of wearing time by means of objective non-invasive determination of wavefront patterns. Methods The crx1 adaptive-optics system was used to measure the wavefront aberrations in 15 myopic eyes before and at 2-h intervals after contact lens fitting, over a 12-h wearing period. Seven types of contact lenses having different material, water content and lens design were evaluated in this study: Dailies Total1, Dailies AquaComfort Plus, Proclear 1 Day, 1-Day Acuvue TruEye, 1-Day Acuvue moist, SofLens daily disposable and Clariti 1-Day. The aberration data were analyse…

AdultMalePoint spread functionOptics and PhotonicsCorneal Wavefront AberrationTime Factorsgenetic structuresZernike polynomialsVisual AcuityPupillaw.inventionYoung Adultsymbols.namesakeOpticslawOptical transfer functionAberrometryMyopiaHumansDisposable EquipmentMathematicsWavefrontbusiness.industryAberrometryContact Lenses Hydrophiliceye diseasesSensory SystemsLens (optics)OphthalmologysymbolsFemalesense organsSpatial frequencybusinessOptometryOphthalmic and Physiological Optics
researchProduct

Electrophysiological brainstem investigations in obstructive sleep apnoea syndrome.

1996

Phasic inspiratory genioglossus activity prevents pharyngeal airway collapse in healthy subjects during sleep and is diminished or absent in obstructive sleep apnoea syndrome (OSAS), thus leading to pharyngeal obstruction. Case reports of OSAS after pontomedullary lesions indicate that impaired inspiratory genioglossal activity may result from brainstem lesions. We therefore investigated brainstem functions in 18 awake patients with OSAS using brainstem auditory evoked potentials, blink reflex, masseter reflex, masseter inhibitory reflex (in 11 of 18 patients), magnetic evoked potentials of the tongue and electrooculography with vestibular testing. Fifteen of 18 patients showed no electroph…

AdultMalePolysomnographyPolysomnographyLesionSleep Apnea Syndromesstomatognathic systemmedicineHumansCorneal reflexGenioglossusmedicine.diagnostic_testbusiness.industryApneaMiddle Agedrespiratory tract diseasesNeurologyAnesthesiaReflexFemaleNeurology (clinical)Brainstemmedicine.symptombusinessJaw jerk reflexBrain StemJournal of neurology
researchProduct

Reproducibility of digital image analysis for measuring corneal haze after myopic photorefractive keratectomy.

1997

Purpose To evaluate the usefulness of digital image analysis for quantifying corneal haze by determining the reproducibility of its measurements at the corneal plane. Methods In a prospective study, 20 randomly selected eyes that had undergone myopic photorefractive keratectomy were photographed focusing the slit beam on their anterior corneal surface. Each photograph was examined using computer image analysis techniques that detect the edge of the reticular pattern of the image. Quantification of the difference between two areas, treated and adjacent untreated cornea, each containing 3,750 pixels with a resolution of 256 gray levels, was performed. Intra-analyzer variation was determined b…

AdultMaleRefractive errormedicine.medical_specialtyHazeMaterials sciencegenetic structuresCoefficient of variationmedicine.medical_treatmentImage processingPhotorefractive KeratectomyCorneaOpticsPostoperative ComplicationsCorneaOphthalmologymedicineImage Processing Computer-AssistedMyopiaHumansProspective StudiesReproducibilityCorneal Hazebusiness.industryReproducibility of ResultsMiddle Agedmedicine.diseaseeye diseasesPhotorefractive keratectomyOphthalmologymedicine.anatomical_structureFemaleLasers Excimersense organsbusinessAmerican journal of ophthalmology
researchProduct

Direct Objective Quantification of Corneal Haze after Excimer Laser Photorefractive Keratectomy for High Myopia

1996

Purpose: The purpose of the study is to measure regional distribution differences in corneal haze after excimer laser photorefractive keratectomy for high myopia. Methods: The authors developed computerized gradient edge detectors with which were analyzed digitized anterior slit-lamp photographs of 40 eyes, an average of 21.0 plus or minus 14.5 weeks after photorefractive keratectomy for high myopia (−6 to −22 diopters). A treated area and an adjacent untreated area on the anterior corneal surface, each containing six regions, were quantified, and the difference was correlated with various parameters. Results: Mean differences between scarred and clear areas for haze grade 0.5, 1.0, 2.0, 3.…

AdultMaleRefractive errormedicine.medical_specialtyHazegenetic structuresmedicine.medical_treatmentExcimerPhotorefractive KeratectomyCorneaCorneal OpacityOphthalmologyCorneaImage Processing Computer-AssistedMyopiamedicineHumansDioptreCorneal Hazebusiness.industryMiddle Agedmedicine.diseaseeye diseasesPhotorefractive keratectomyOphthalmologymedicine.anatomical_structureFemaleLasers Excimersense organsbusinessFollow-Up StudiesAblation zoneOphthalmology
researchProduct

Mesopic Contrast Sensitivity Function After Laser in situ Keratomileusis

2003

ABSTRACT PURPOSE: To evaluate contrast sensitivity under mesopic conditions in patients who have undergone uncomplicated bilateral laser in situ keratomileusis (LASIK) for myopia. METHODS: Best-corrected monocular contrast sensitivity was measured with the Stereo Optical F.A.C.T. chart at 1.5, 3, 6, 12, and 18 c/deg in 20 patients (20 left eyes) before and after bilateral LASIK (with the Nidek EC-5000 excimer laser and the Automated Corneal Shaper). Mean preoperative refractive error was -6.40 ± 1.28 D (range -4.00 to -8.00 D) and postoperative mean refractive error was -0.41 ± 0.45 D (range -0.75 to +0.50 D). Contrast sensitivity function was measured before and 6 months after surgery usin…

AdultMaleRefractive errormedicine.medical_specialtyMaterials scienceLightgenetic structuresMesopic visionEye diseasemedia_common.quotation_subjectmedicine.medical_treatmentKeratomileusis Laser In SituKeratomileusisContrast SensitivityCorneaVision disorderOphthalmologyMyopiamedicineHumansContrast (vision)media_commonLASIKmedicine.diseaseeye diseasesSurgeryOphthalmologyFemaleSurgerysense organsmedicine.symptomPhotopic visionJournal of Refractive Surgery
researchProduct

Iris Claw Phakic Intraocular Lens for High Myopia

1997

ABSTRACT BACKGROUND: The implantation of a WorstFechner iris claw intraocular lens (IOL) is one of the surgical procedures used for the correction of high myopia. This technique reduces myopia with stähle refractive results; however, its potential long-term risks have not been evaluated. We report results in 94 eyes with a minimum follow -up of 3 years. METHODS: We studied 94 eyes of 62 patients with myopia 5= -7.00 diopters (D) who underwent Worst-Fechner IOL implantation. Lens decentration, permeability of the blood-aqueous barrier by iris angiography, and changes in corneal endothelial density were analyzed. RESULTS: Mean follow-up time was 48.9 months (range 36 to 72 mo). Three years af…

AdultMaleRefractive errormedicine.medical_specialtyTime FactorsVisual acuitygenetic structuresEye diseasemedicine.medical_treatmentVisual AcuityIrisEmmetropiaIntraocular lensRefraction OcularPhakic intraocular lensVision disorderPostoperative ComplicationsOphthalmologyMyopiamedicineHumansDioptreAgedRetrospective StudiesLenses Intraocularbusiness.industryEndothelium CornealMiddle Agedmedicine.diseaseeye diseasesOphthalmologyTreatment OutcomeFemaleSurgerysense organsmedicine.symptombusinessFollow-Up StudiesJournal of Refractive Surgery
researchProduct

Excimer laser photorefractive keratectomy for high myopia

1995

Abstract One hundred and thirty-three eyes of 103 patients had photorefractive keratectomy with a slit scan mode excimer laser for myopia ranging from −6.00 to −22.00 diopters (D). The epithelium was removed with 20% ethanol, and the ablation was done with a tapered profile surrounding the optical zone. Patients were divided into two groups based on preoperative myopia: Group A, −6.00 D to −12.00 D (88 eyes); Group B, −12.50 D to −22.00 D (45 eyes). In Group A, mean preoperative refraction was −9.59 ± 1.79 D. Mean postoperative refraction was −0.29 ± 1.47 D at one month, −0.85 ± 1.68 D at three months, −1.17 ± 2.04 D at six months, and −0.56 ± 0.74 D at one year. Anterior stromal haze was g…

AdultMaleRefractive errormedicine.medical_specialtygenetic structuresCorneal Stromamedicine.medical_treatmentEye diseaseVisual AcuityRefraction OcularExcimerPhotorefractive KeratectomyEpitheliumCorneaVision disorderCorneal OpacityOphthalmologyMyopiamedicineHumansIntraocular PressureDioptreExcimer laserbusiness.industryMiddle AgedPrognosismedicine.diseaseAblationeye diseasesSensory SystemsPhotorefractive keratectomyOphthalmologyFemaleLasers ExcimerSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct