Search results for "corn"
showing 10 items of 710 documents
Menhires/monolitos: estructuras monolíticas en el sector central de la cornisa cantábrica
1995
Abordar el estudio de los menhires exige plantear previamenle una cuestión terminológica y por ende de conceptualización del fenómeno y en relación con ello de asignación cronocultural y funcional de las evidencias. El tema podria reducirse a tres grupos de preguntas: ¿es adecuada esta terminología para las manifestaciones de la zona?, ¿qué monumentos debemos considerar Menhires?, y ¿qué grupos humanos son responsables de su construcción y qué papel desempeñaron estas estructuras dentro de su sistema ideológico?. An approach to the study of menhirs requires some preliminary questios, first a terminological one and, consequently, of conceptualization of the phenomenon and in relation to this…
Diversidad liquénica asociada a fenómenos post-incendio en los alcornocales valenciano-castellonenses.
2001
FOS, S., CALATAYUD, A. & BARRENO, E. 2001. Lichen diversity associated with post-fire colonization in the Valenciano-castellonense cork-oak forests. Bot. Complutensis 25: 103113. 103 Simón Fos et al. Diversidad liquénica asociada a fenómenos post-incendio... The post-fire colonization of the burned barks of cork-oaks (Quercus suber L.) by epiphytic lichens affected by fire episodes has been studied in different areas of the Valenciano-castellonense cork-oak forests (Asplenio onopteridis-Querco suberis sigmetum). These forests, which have been affected by fires of different intensity, are located in Espadán and Calderona mountains and in the Desierto de Las Palmas and differ with respect…
Increated central corneal thickness in acromegalic patients
2009
Air bubble location inside the uterus after transfer: is the embryo really there?
2007
Objective To demonstrate that the location of the air bubble after embryo transfer (ET) does not necessarily indicate the final embryo location. Design Case report. Setting Private clinic. Patient(s) A couple with primary infertility for whom a diagnosis of bicornuate uterus with a very open angle between horns was confirmed. Intervention(s) Laparoscopy and hysteroscopy were performed before an IVF cycle in which a single embryo was replaced. Main Outcome Measure(s) Air bubble image immediately after ET and gestational sac location 3 weeks later. Result(s) Immediately after a single ET, the air bubble was seen in the left uterine horn. Three weeks later, a gestational sac was seen in the ri…
Skin-PAMPA: a new method for fast prediction of skin penetration.
2011
The goal of this study was to develop a quick, reliable, and cost-effective permeability model for predicting transdermal penetration of compounds. The Parallel Artificial Membrane Permeability Assay (PAMPA) was chosen for this purpose, as it already has been successfully used for estimating passive gastrointestinal absorption and blood-brain barrier permeability. To match the permeability of the rate-limiting barrier in human skin, synthetic certramides, which are analogs of the ceramides present in the stratum corneum, were selected for the skin-PAMPA model. The final skin-PAMPA membrane lipid mixture (certramide, free fatty acid, and cholesterol) was selected and optimized based on data …
Survival After Transplantation of Corneas From a Rabies-Infected Donor
2011
To examine the tissue samples of 2 corneal recipients from a rabies-infected donor for the presence of rabies to explain their survival.Interventional case series with a review of the literature. The explanted corneal donor buttons were examined via nested reverse transcriptase polymerase chain reaction. The patients were followed up ophthalmologically and neurologically. Antirabies antibodies were measured in blood samples, and skin biopsies were examined by direct fluorescent antibody staining.Two patients received corneas from the same multiorgan donor. Six weeks after transplantation, 3 of the donor's organ recipients became symptomatic and rabies virus was confirmed in tissue from the …
Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…
2012
AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…
Effect of Simulated IOL Tilt and Decentration on Spherical Aberration After Hyperopic LASIK for Different Intraocular Lenses
2011
PURPOSE: To evaluate visual quality differences among intraocular lenses (IOLs) in patients with previous hyperopic laser ablations and to assess the impact of decentration and tilt of IOLs on visual quality. METHODS: An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of one aberration-correcting IOL (AcrySof IQ SN60WF, Alcon Laboratories Inc) and two spherical IOLs with different amounts of positive spherical aberration (Akreos Adapt [Bausch & Lomb] and Triplato [AJL Ophthalmic]) in five situations—centered, 0.2 mm and 0.4 mm of decentration, and 2° and 4° of tilt—in two groups: simulated low hyperopic laser corneal ablation (low hyperopia group)…
Visual simulation through an aspheric aberration-correcting intraocular lens in subjects with different corneal profiles using adaptive optics.
2013
The aim of this study was to analyse the visual quality of the AcrySof IQ SN60WF® intraocular lens (IOL) when combined with different corneal profiles. Ten eyes of 10 participants with no prior history of refractive or cataract surgery were evaluated. An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of an aspheric aberration-correcting IOL (AcrySof IQ SN60WF®). Normal corneas (group A), low and high myopic corneal ablations (groups B and C, respectively) and low and high hyperopic corneal ablations (groups D and E, respectively) were also simulated. Monocular distance visual acuities at 100, 50 and 10 per cent of contrast were measured. At 100, 50 an…
Lentes de contato corneoesclerais adaptadas em córneas irregulares após cirurgia LASIK
2018
ABSTRACT Purpose: We aimed to describe the outcomes of corneoscleral contact lens fitting with multi-aspherical geometry designs in patients with irregular corneas after laser-assisted in situ keratomileusis (LASIK). Methods: This was a retrospective series of 18 patients (age, 26-38 years) selected from an eye clinic database. Participants were required to have unsatisfactory visual acuity with their current contact lenses or spectacles after LASIK for myopia correction. All patients were fitted with corneoscleral contact lenses designed to correct corneal surface irregularities. A diagnostic trial set was used for fitting, and assessments were performed according to a standardized methodo…