Search results for "coronary circulation"
showing 10 items of 75 documents
Predictors of cardiovascular magnetic resonance-derived microvascular obstruction on patient admission in STEMI
2010
Early stratification of patients according to the risk for developing microvascular obstruction (MVO) after ST-segment elevation myocardial infarction (STEMI) is desirable. We aimed to identify predictors of cardiovascular magnetic resonance (CMR)-derived MVO from clinical+ECG, laboratory and angiographic parameters available on admission.Characteristics available on admission were documented in 97 STEMI patients referred for primary angioplasty. MVO was determined using contrast-enhanced CMR.MVO was present in 44 patients (45%). The C-statistic for predicting MVO was: clinical+ECG (.832), laboratory (.743), and angiographic parameters (.669). Adding laboratory to clinical+ECG information d…
Cardiac Micro–Computed Tomography Imaging of the Aging Coronary Vasculature
2012
Background— Alterations at the level of the coronary circulation with aging may play an important role in the evolution of age-associated changes in left ventricular (LV) fibrosis and function. However these age-associated changes in the coronary vasculature remain poorly defined primarily due to the lack of high resolution imaging technologies. The current study was designed to utilize cardiac micro–computed tomography (micro-CT) technology as a novel imaging strategy, to define the 3-dimensional coronary circulation in the young and aged heart and its relationship to LV fibrosis and function. Methods and Results— Young (2 months old; n=10) and aged (20 months old; n=10) Fischer rats unde…
Application of C1-Esterase Inhibitor During Reperfusion of Ischemic Myocardium
2001
Background—Complement activation during reperfusion of ischemic myocardium augments myocardial injury, and complement inhibition with C1-esterase inhibitor (C1-INH) at the time of reperfusion exerts marked cardioprotective effects in experimental studies. Application of C1-INH in newborns, however, was recently reported to have dangerous and even lethal side effects. This study addresses the essential role of dosage in studies using C1-INH.Methods and Results—Cardioprotection by C1-INH was examined in a pig model with 60 minutes of coronary occlusion followed by 120 minutes of reperfusion. C1-INH was administered intravenously 5 to 10 minutes before coronary reperfusion without heparin at a…
Difference in hemodynamic and wall stress of ascending thoracic aortic aneurysms with bicuspid and tricuspid aortic valve.
2012
The aortic dissection (AoD) of an ascending thoracic aortic aneurysm (ATAA) initiates when the hemodynamic loads exerted on the aneurysmal wall overcome the adhesive forces holding the elastic layers together. Parallel coupled, two-way fluid–structure interaction (FSI) analyses were performed on patient-specific ATAAs obtained from patients with either bicuspid aortic valve (BAV) or tricuspid aortic valve (TAV) to evaluate hemodynamic predictors and wall stresses imparting aneurysm enlargement and AoD. Results showed a left-handed circumferential flow with slower-moving helical pattern in the aneurysm's center for BAV ATAAs whereas a slight deviation of the blood flow toward the anterolater…
Echocardiographic and angiographic evaluation of left ventricular function during percutaneous transluminal aortic valvuloplasty.
1992
Transesophageal echocardiography was used to study the effect of the balloon inflation on left ventricular function in 20 patients with critical aortic stenosis undergoing balloon valvuloplasty. Balloon inflation caused an increase of end-diastolic (15% to 34%) and end-systolic (57% to 72%) left ventricular volume. Left ventricular wall stress increased from 30 +/- 10 x 10(3) dyn/cm2 at diastole and 121 +/- 40 x 10(3) dyn/cm2 at systole to 44 +/- 11 x 10(3) dyn/cm2 and 191 +/- 55 x 10(3) dyn/cm2, respectively, when the balloon was inflated (P less than 0.05). Turbulent regurgitant jet across the mitral valve increased from 15 +/- 2% to 25 +/- 3% during balloon inflation (P less than 0.01). …
Safety and feasibility of atropine added in patients with sub-maximal heart rate during exercise myocardial perfusion SPECT.
2006
Failure to reach 80% of maximal predicted heart rate (HR) during exercise may render a myocardial perfusion single photon emission computed tomography (SPECT) study non-diagnostic for ischemia detection. We sought to investigate the injection of atropine in patients who fail to achieve 80% of age-predicted HR during exercise performed for myocardial perfusion SPECT (MPS), defining its safety and efficacy to raise HR to adequate levels as well as its effect on MPS interpretation.Between January 2002 and December 2004, we studied 3,150 consecutive patients (2,253 men and 897 women, mean age 55 +/- 6 years) who were referred to a single office-based nuclear cardiology laboratory for MPS using …
[Coronary microvascular dysfunction: past, present, and future of an evolving disease].
2017
Coronary atherosclerosis is the main cause of myocardial ischemia. Nevertheless 10-30% of patients with angina has angiographically normal coronary arteries. In the last 30 years, several studies showed that in these patients the symptoms can be caused by dysfunction of the coronary microcirculation. Coronary microvascular dysfunction (CMVD) occurring in patients affected by specific cardiac or systemic diseases may be due to mechanisms of the underlying disease. On the other hand, in several patients affected by angina with angiographically normal coronary arteries, there is no specific disease, and CMVD only is responsible for the clinical picture. This condition can be defined as leading…
[Diagnosis of coronary microvascualar dysfunction in diabetic patients with cardiac syndrome X: comparison by current methods].
2013
The study population included 208 patients with chest pain and uninjured coronary arteries that we split into two populations: diabetics (72 patients) and non-diabetics (136 patients). We split patients with chest pain and uninjured coronary arteries that had a myocardial scintigraphy into two populations: patients with positive scintigraphy and negative. We calculated, on angiographic images of each patient, stored on suitable digital supports, Timi Frame Count (TFC), Myocardial Blush Grade (MBG) and Total Myocardial Blush Score (TMBS) using the protocol described by Gibson and Yusuf. On the basis of Yusuf's experience we imagined a new index: the Total Timi Frame Count as the sum of the t…
Critical single proximal left arterial descending coronary artery stenosis to mimic chronic myocardial ischemia: a new model induced by minimal invas…
2008
<i>Background/Aims:</i> The present report examines a new pig model for progressive induction of high-grade stenosis, for the study of chronic myocardial ischemia and the dynamics of collateral vessel growth. <i>Methods:</i> Thirty-nine Landrace pigs were instrumented with a novel experimental stent (GVD stent) in the left anterior descending coronary artery. Eight animals underwent transthoracic echocardiography at rest and under low-dose dobutamine. Seven animals were examined by nuclear PET and SPECT analysis. Epi-, mid- and endocardial fibrosis and the numbers of arterial vessels were examined by histology. <i>Results:</i> Functional analysis showed a…
Prevalence of anatomical variants and coronary anomalies in 543 consecutive patients studied with 64-slice CT coronary angiography
2008
The aim of our study was to assess the prevalence of variants and anomalies of the coronary artery tree in patients who underwent 64-slice computed tomography coronary angiography (CT-CA) for suspected or known coronary artery disease. A total of 543 patients (389 male, mean age 60.5 +/- 10.9) were reviewed for coronary artery variants and anomalies including post-processing tools. The majority of segments were identified according to the American Heart Association scheme. The coronary dominance pattern results were: right, 86.6%; left, 9.2%; balanced, 4.2%. The left main coronary artery had a mean length of 112 +/- 55 mm. The intermediate branch was present in the 21.9%. A variable number …