A comparison of three different micro-tomography systems for accurate determination of microvascular parameters
2008
The investigation of micro-vessel dimensions in 3D is currently problematic due to their complex structures and fine scale. Quantification of vascular parameters is important in several fields of biomedicine; including embryogenesis, wound healing, diseases characterized by uncontrolled angiogenesis (e.g. tumor growth and metastasis) and the development of implantable bio-materials where a functional vascular supply is critical to their successful integration into host tissue. However, techniques that can resolve the micron-scaled features of these capillary beds, such as scanning electron and confocal microscopy, do not allow for total image reconstitution in 3 D in thick tissue samples [1…
Sprouting and intussusceptive angiogenesis in postpneumonectomy lung growth: mechanisms of alveolar neovascularization
2013
In most rodents and some other mammals, the removal of one lung results in compensatory growth associated with dramatic angiogenesis and complete restoration of lung capacity. One pivotal mechanism in neoalveolarization is neovascularization, because without angiogenesis new alveoli can not be formed. The aim of this study is to image and analyze three-dimensionally the different patterns of neovascularization seen following pneumonectomy in mice on a sub-micron-scale. C57/BL6 mice underwent a left-sided pneumonectomy. Lungs were harvested at various timepoints after pneumonectomy. Volume analysis by microCT revealed a striking increase of 143 percent in the cardiac lobe 14 days after pneum…
Inflammation-Induced Intussusceptive Angiogenesis in Murine Colitis
2010
Intussusceptive angiogenesis is a morphogenetic process that forms new blood vessels by the division of a single blood vessel into two lumens. Here, we show that this process of intraluminal division participates in the inflammation-induced neovascularization associated with chemically induced murine colitis. In studies of both acute (4-7 days) and chronic (28-31 days) colitis, intravital microscopy of intravascular tracers demonstrated a twofold reduction in blood flow velocity. In the acute colitis model, the decreased velocity was associated with marked dilatation of the mucosal plexus. In contrast, chronic inflammation was associated with normal caliber vessels and duplication (and trip…
Intravascular pillars and pruning in the extraembryonic vessels of chick embryos.
2010
To investigate the local mechanical forces associated with intravascular pillars and vessel pruning, we studied the conducting vessels in the extraembryonic circulation of the chick embryo. During the development days 13-17, intravascular pillars and blood flow parameters were identified using fluorescent vascular tracers and digital time-series video reconstructions. The geometry of selected vessels was confirmed by corrosion casting and scanning electron microscopy. Computational simulations of pruning vessels suggested that serial pillars form along pre-existing velocity streamlines; blood pressure demonstrated no obvious spatial relationship with the intravascular pillars. Modeling a Re…
The murine bronchopulmonary microcirculation in hapten-induced inflammation
2006
ObjectiveThe clinical observation of central bronchial artery hypertrophy in chronic lung inflammation suggests the possibility that the bronchial circulation may also participate in adaptive responses in peripheral lung inflammation.MethodsTo investigate the potential role of the bronchial microcirculation in peripheral lung inflammation, we developed a murine model of lung inflammation using the intratracheal instillation of the peptide-hapten trinitrophenol in presensitized mice.ResultsClinical parameters indicated a peak inflammatory response at 96 hours. Similarly, gross and microscopic evidence of inflammation was observed 96 hours after antigen instillation. Using a forced oscillatio…
Structural and functional evidence for the scaffolding effect of alveolar blood vessels
2017
A contribution of pulmonary blood distension to alveolar opening was first proposed more than 100 years ago. To investigate the contribution of blood distension to lung mechanics, we studied control mice (normal perfusion), mice after exsanguination (absent perfusion) and mice after varying degrees of parenchymal resection (supra-normal perfusion). On inflation, mean tracheal pressures were higher in the bloodless mouse (4.0α2.5 cmH2O); however, there was minimal difference between conditions on deflation (0.7α0.9 cmH2O). To separate the peripheral and central mechanical effects of blood volume, multi-frequency lung impedance data was fitted to the constant-phase model. The presence or abse…
External Volume Expansion Increases Subcutaneous Thickness, Cell Proliferation, and Vascular Remodeling in a Murine Model
2012
Background Fat grafting is a powerful tool for soft-tissue reconstruction; however, the science behind recipient bed preparation has not been thoroughly explored. External volume expansion using suction before fat grafting has been used clinically to improve reliability and consistency of graft survival. The authors developed a murine model to investigate the underlying mechanism of external volume expansion. Methods The authors created an external volume expansion device using a soft-silicone dome connected to a vacuum source (25 mmHg) to treat the dorsum of mice, and the response was compared with treatment with an occlusive dressing. Treated areas were monitored with magnetic resonance i…
Stretch-induced Intussuceptive and Sprouting Angiogenesis in the Chick Chorioallantoic Membrane
2014
Vascular systems grow and remodel in response to not only metabolic needs, but also mechanical influences as well. Here, we investigated the influence of tissue-level mechanical forces on the patterning and structure of the chick chorioallantoic membrane (CAM) microcirculation. A dipole stretch field was applied to the CAM using custom computer-controlled servomotors. The topography of the stretch field was mapped using finite element models. After 3 days of stretch, Sholl analysis of the CAM demonstrated a 7-fold increase in conducting vessel intersections within the stretch field (p 0.05). In contrast, corrosion casting and SEM of the stretch field capillary meshwork demonstrated intense …