Search results for "current"
showing 10 items of 2224 documents
Analytical compact modeling of GMR based current sensors: Application to power measurement at the IC level
2010
An analytical compact model for giant magnetoresistance (GMR) based current sensors has been developed. Different spin-valve based full Wheatstone bridge sensors, with the current straps integrated in the chip, have been considered. These devices have been experimentally characterized in order to extract the model parameters. In this respect, we have focused on the sensors linear operation regime. The model, which allows the individual description of the magnetoresistive elements, has been implemented in a circuit simulator by means of a behavioral description language: Verilog-A. We also propose the use of the devices in a direct power measurement application at the integrated circuit (IC)…
Vibration signature analysis for rotor broken bar diagnosis in double cage induction motor drives
2013
The paper investigates the diagnosis of rotor broken bars in field oriented controlled (FOC) double cage induction motor drives, using current and vibration signature analysis techniques. The Impact of the closed loop control system cannot be neglected when the detection of asymmetries in the machine are based on the signature analysis of electrical variables. The proposed diagnosis approach is based on optimized use of wavelet analysis by a pre-processing of phase current or axial/radial vibration signals. Thus, the time evolution of the tracked rotor fault components can be effectively analyzed. This paper shows also the relevance of the fault components computed from axial vibration sign…
Arc Fault Detection Method Based on CZT Low-Frequency Harmonic Current Analysis
2017
This paper presents a method for the detection of series arc faults in electrical circuits, which has been developed starting from an experimental characterization of the arc fault phenomenon and an arcing current study in several test conditions. Starting from this, the authors have found that is it possible to suitably detect arc faults by means of a high-resolution low-frequency harmonic analysis of current signal, based on chirp zeta transform, and a proper set of indicators. The proposed method effectiveness is shown by means of experimental tests, which were carried in both arcing and nonarcing conditions and in the presence of different loads, chosen according to the UL 1699 standard…
Current Trends on the Acquisition, Virtual Representation, and Interaction of Cultural Heritage
2020
Cultural heritage (CH) tells us about our roots, and therefore, constitutes a rich value for the society. Its conservation, dissemination, and understanding are of utmost importance. In order to preserve CH for the upcoming generations, it needs to be documented, a process that nowadays is done digitally. Current trends involve a set of technologies (cameras, scanners, etc.) for the shape and radiometric acquisition of assets. Also, intangible CH can be digitally documented in a variety of forms. Having such assets virtualized, a proper dissemination channel is of relevance, and recently, new technologies that make use of interaction paradigms have emerged. Among them, in this chapter, the …
Sub-mA current measurement by means of GMR sensors and state of the art lock-in amplifiers
2015
Electric current measurement at the range of μA in integrated circuit has been traditionally carried out by micro-electronically engineered systems, such as current mirrors or charging capacitors. However, off-line, i.e., non-intrusive methods provide advantages related to size and power consumption. In this sense, giant magnetoresistance (GMR) magnetic sensors are optimal due to their sensitivity and CMOS compatibility. In this work, we make use of specifically designed CMOS GMR-based current sensors in combination with a custom electronic interface based on a low-voltage low-power lock-in amplifier, demonstrating the capability of this combination for current measurement in the range of μ…
Design and experimental verification of a smart sensor to measure the energy and power consumption in a one-phase AC line
2009
Abstract A mixed electronic system has been designed to measure the active, apparent and reactive energies delivered to a load in a single-phase AC voltage line. For this purpose a smart sensor (ADE7753 from Analog Devices) was used. A magnetoresistance sensor is used as a current transducer and it is constant current biased by a generalized impedance converter. The magnetoresistance sensor technology provides direct isolation from the mains voltage and ferrite cores are not needed like Hall counterparts. All the measurements provided by the ADE7753 are read through the parallel port of the computer using a LabView application, which will process and present the readings to the user.
DC link voltage swinging and load current unbalance in fault tolerant VSI. overview and compensation strategies
2015
The topic of this paper is the discussion on the performance of a three-phase fault tolerant inverter with particular attention to the underrated aspect of current unbalances occurring due to the DC link voltage fluctuates after the inverter reconfiguration. Capacitor voltage unbalance affects not only the average output voltage of the inverter, but also its performance. In fact, the inverter performance depends on the fluctuating DC-link voltage components rather than on the average DC-link voltage. After a brief analysis of the voltage fluctuation phenomena resulting from fault tolerant configuration and their effect on load current unbalance, the Authors consider different compensating p…
Reducing DC Link Voltage Unbalance in a Fault-Tolerant Inverter
2014
Today, continuous working of power inverter drives is mandatory for several applications. Damages to materials, machines or even risks to human life have to be absolutely avoided. In the literature, fault-tolerant algorithms and architectures to achieve a successful fault handling are investigated. Researchers aim at reducing the number and cost of additional components, improving at the same time the inverter performances under postfault conditions. Cost, post-fault power derating and increasing distortion are usually conflicting requirements. In this paper, a fault-tolerant three phase inverter is presented. A reconfigurable architecture and a novel fault-tolerant algorithm is designed to…
Magnetic Tunnel Junction (MTJ) Sensors for Integrated Circuits (IC) Electric Current Measurement
2013
We report on MgO Magnetic Tunnel Junction (MTJ) devices focusing on their potential application in the measurement of electrical current at the integrated circuit level. Single devices and full bridges have been specifically developed for this purpose. A sort of different designs regarding their geometry arrangement as well as the number of constitutive elements have been tested. Experimental characterization has been performed and results including impedance and sensitivity measurements are given.
A new backward/forward method for solving radial distribution networks with PV nodes
2008
Abstract In this paper, a new backward/forward (b/f) methodology for the analysis of distribution systems with constant power loads is presented. In the proposed method, at each iteration, the loads are considered as constant impedances; in the backward sweep all the network variables (bus voltages and branch currents) are evaluated considering a scaling factor which is determined at the end of the backward phase. Indeed the forward sweep is eliminated and the node voltages calculation does not demand the sequentiality needed in the b/f methodology. The developed method, although deriving conceptually from the b/f methodology, presents only the backward phase in which all the network variab…