Search results for "cyclotron"
showing 10 items of 320 documents
The electron cyclotron resonance ion source with arc-shaped coils concept
2012
The main limitation to further improve the performance of ECR ion sources is set by the magnet technology related to the multipole magnet field used for the closed minimum-B structure. The JYFL ion source group has sought different approaches to improve the strength of the minimum-B structure required for the production of highly charged ion beams. It was found out that such a configuration can be realized with arc shaped coils. The first prototype, electron cyclotron resonance ion source with arc-shaped coils (ARC-ECRIS), was constructed and tested at JYFL in 2006. It was confirmed that such an ion source can be used for the production of highly charged ion beams. Regardless of several cos…
First experiments with gasdynamic ion source in CW mode.
2016
A new type of ECR ion source—a gasdynamic ECR ion source—has been recently developed at the Institute of Applied Physics. The main advantages of such device are extremely high ion beam current with a current density up to 600–700 emA/cm2 in combination with low emittance, i.e., normalized RMS emittance below 0.1 π mm mrad. Previous investigations were carried out in pulsed operation with 37.5 or 75 GHz gyrotron radiation with power up to 100 kW at SMIS 37 experimental facility. The present work demonstrates the first experience of operating the gasdynamic ECR ion source in CW mode. A test bench of SMIS 24 facility has been developed at IAP RAS. 24 GHz radiation of CW gyrotron was used for p…
Double einzel lens extraction for the JYFL 14 GHz ECR ion source designed with IBSimu
2013
In order to improve the performance of the JYFL 14 GHz electron cyclotron resonance ion source (ECRIS) and initiate low energy beam transport (LEBT) upgrade at the University of Jyvaskyla, Department of Physics (JYFL) accelerator laboratory, a new ion beam extraction system has been designed and installed. The development of the new extraction was performed with the ion optical code IBSimu, making it the first ECRIS extraction designed with the code. The measured performance of the new extraction is in good agreement with the simulations. Compared to the old extraction the new system provides improved beam quality, i.e. lower transverse emittance values and improved structure of beam profil…
ECRIS plasma spectroscopy with a high resolution spectrometer
2020
Electron Cyclotron Resonance Ion Source (ECRIS) plasmas contain high-energy electrons and highly charged ions implying that only noninvasive methods such as optical emission spectroscopy are reliable in their characterization. A high-resolution spectrometer (10 pm FWHM at 632 nm) enabling the detection of weak emission lines has been developed at University of Jyväskylä, Department of Physics (JYFL) for this purpose. Diagnostics results probing the densities of ions, neutral atoms, and the temperature of the cold electron population in the JYFL 14 GHz ECRIS are described. For example, it has been observed that the cold electron temperature drops from 40 eV to 20 eV when the extraction volta…
Efficiency of an on-line isotope separator system employing cooled and NaCl-loaded He-jet methods
1976
Abstract A pure helium-jet at liquid nitrogen temperature coupled to a Nielsen type ion source, and a NaCl-loaded helium-jet coupled to a hollow-cathode ion source have been investigated as means to connect a cyclotron target chamber on-line to a mass separator. Technical details and performances of some critical parts of the system are described. Total separation efficiencies measured under various experimental conditions for several nuclides vary between 0.01 and 1.0%.
A Penning Trap for Studying Cluster Ions
1986
We propose to use a Penning trap for spectroscopy of stored cluster ions. A similar device has been built for the purpose of mass measurements of short-lived nuclei produced at the on-line isotope separator ISOLDE/CERN. A resolving power of 500,000 in a mass measurement of39K and an accuracy of 2 × 10−7 for the85Rb/39K mass ratio were obtained. An efficiency for in-flight capture as high as 70% was achieved. The method provides very high sensitivity since typically only 10 to 100 ions are stored in the trap. We intend to perform laser spectroscopy on trapped Na clusters as a first application of the trap technique.
Limits on the release of Rb isotopes from a zeolite based 83mKr calibration source for the XENON project
2011
The isomer 83mKr with its half-life of 1.83 h is an ideal calibration source for a liquid noble gas dark matter experiment like the XENON project. However, the risk of contamination of the detector with traces of the much longer lived mother isotop 83Rb (86.2 d half-life) has to be ruled out. In this work the release of 83Rb atoms from a 1.8 MBq 83Rb source embedded in zeolite beads has been investigated. To do so, a cryogenic trap has been connected to the source for about 10 days, after which it was removed and probed for the strongest 83Rb gamma-rays with an ultra-sensitive Germanium detector. No signal has been found. The corresponding upper limit on the released 83Rb activity means tha…
The SMILETRAP facility
1995
The SMILETRAP experimental set-up, a Penning trap mass spectrometer for highly charged ions, is described. Capture and observation of cyclotron frequencies of externally produced highly charged ions, rapid interchange of investigated and reference ions and measurements of the rotational kinetic energies are demonstrated. Mass measurements utilizing different charge states and species to verify the consistency of the measurements are presented. A relative uncertainty of about 10−9 is attained in comparisons between highly charged carbon, nitrogen, oxygen, neon and the singly charged hydrogen molecule.
Radioactive ion beam manipulation at the IGISOL-4 facility
2020
The IGISOL-4 facility in the JYFL Accelerator Laboratory of the University of Jyvaskyla (JYFL-ACCLAB) produces low-energy radioactive ion beams, primarily for nuclear spectroscopy, utilizing an ion guide-based, ISOL-type mass separator. Recently, new ion manipulation techniques have been introduced at the IGISOL-4 including the application of the PI-ICR (Phase-Imaging Ion Cyclotron Resonance) technique at the JYFLTRAP Penning trap, as well as commissioning of a Multi-Reflection Time-Of-Flight (MR-TOF) separator/spectrometer. The successful operation of the MR-TOF also required significant improvement of the Radio-Frequency Quadrupole (RFQ) cooler and buncher device beam pulse time structure…
Accuracy tests of atomic mass measurements in a penning trap using externally produced highly charged ions
1997
The SMILETRAP experimental set-up, a Penning trap mass spectrometer for highly charged ions, is described. Capture and observation of cyclotron frequencies of externally produced highly charged ions is demonstrated. Mass measurements utilizing different charge states and species to verify the consistency of the measurements are presented. A relative uncertainty <3 10−9 is attained in comparisons between highly charged 12C, 14N, 16O, 20Ne and singly charged H, H2 and H3 ions. The current limitations and future developments are discussed.