Search results for "cyclotron"

showing 10 items of 320 documents

New Results from the NUMEN Project

2018

International audience; NUMEN aims at accessing experimentally driven information on Nuclear Matrix Elements (NME) involved in the half-life of the neutrinoless double beta decay (0νββ), by high-accuracy measurements of the cross sections of Heavy Ion (HI) induced Double Charge Exchange (DCE) reactions. First evidence about the possibility to get quantitative information about NME from experiments is found for the (^18O,^18Ne) and (^20Ne,^20O) reactions. Moreover, to infer the neutrino average masses from the possible measurement of the half-life of 0νββ decay, the knowledge of the NME is a crucial aspect. The key tools for this project are the high resolution Superconducting Cyclotron beam…

Semileptonic decayheavy ion: scatteringCyclotronContext (language use)[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]7. Clean energy01 natural scienceslaw.inventionNuclear physicsdouble-beta decay: (0neutrino)lawDouble beta decay0103 physical sciencescyclotron010306 general physicsPhysicsnucleus: semileptonic decaySpectrometer010308 nuclear & particles physicsresolutioncross section: measuredmagnetic spectrometercharge exchangeUpgradeupgradeNeutrinoOrder of magnitudeexperimental results
researchProduct

Analysis of Air Discharges from a PET Radiopharmaceuticals Production Center Based on a Cyclotron

2012

The control of air contamination in a Nuclear Medicine Center (NMC) provided with a cyclotron for the production of radiopharmaceuticals is based on an automatic systems for air sampling and measurements. An important control for the assessment of dose to the population is aimed at the measurement of air concentration of stack release and inside the cyclotron vault during irradiation. The frequency of sampling can be setup as continuous with respect to the stack effluent release and cyclic for other work environments. The gamma-ray spectrometric measurement are made on-line and for a short time by using a shielded Marinelli beaker filled with sampled air and a gamma detector. The use of thi…

Settore ING-IND/20 - Misure E Strumentazione NucleariMedical cyclotron PET radioactive air effluent
researchProduct

An electrospray ionization Fourier transform ion cyclotron resonance mass spectrometric study of the gas-phase stabilities and fragmentation ofN-alky…

2006

Five N-alkylated ammonium resorcarene derivatives, differing either in the nitrogen atom or in the lower rim alkyl chain, were studied using electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry. The main purpose was to clarify the fragmentation and the relative stabilities of the protonated molecules by collision-induced dissociation (CID) experiments. The results indicate that fragmentation of the upper rim alkyl amino substituents at the 2-position occurs readily. Variation in the gas-phase stabilities of these molecules was also observed. In addition, the proposed fragmentation pathways are depicted.

Spectrometry Mass Electrospray IonizationChemical ionizationAlkylationCollision-induced dissociationChemistryElectrospray ionizationOrganic ChemistryAnalytical chemistryResorcinolsCyclotronsMass spectrometryPhase TransitionIon sourceFourier transform ion cyclotron resonanceAnalytical ChemistryQuaternary Ammonium CompoundsFragmentation (mass spectrometry)OxazinesSpectroscopy Fourier Transform InfraredGasesSpectroscopyIon cyclotron resonanceRapid Communications in Mass Spectrometry
researchProduct

Mass spectrometric studies of benzoxazine resorcarenes

2002

Eleven differently substituted 3,4-dihydro-2H-1,3-benzoxazine resorcarenes were studied by electrospray ionisation (ESI) and matrix-assisted laser desorption/ionisation (MALDI) mass spectrometry, using Fourier transform ion cyclotron resonance (FT-ICR) and time-of-flight (TOF) mass spectrometers, respectively. Under ESI conditions it was possible to transfer the intact resorcarenes from solution to the gas phase, yielding [M + H]+ and [M + 2H]+ ions as the main ions observed. Energy increase of the ions induced ready decomposition through successive eliminations of four CH2NR groups. Ion-molecule reactions showed that the ionising proton was situated somewhere inside the molecule and could …

Spectrometry Mass Electrospray IonizationElectrosprayChemistryOrganic ChemistryAnalytical chemistryResorcinolsMass spectrometryAlkali metalFourier transform ion cyclotron resonanceAnalytical ChemistryIonFragmentation (mass spectrometry)Spectrometry Mass Matrix-Assisted Laser Desorption-IonizationReagentOxazinesMoleculeSpectroscopyRapid Communications in Mass Spectrometry
researchProduct

Mobility determination of lead isotopes in glass for retrospective radon measurements

2008

In retrospective radon measurements, the 22-y half life of (210)Pb is used as an advantage. (210)Pb is often considered to be relatively immobile in glass after alpha recoil implanted by (222)Rn progenies. The diffusion of (210)Pb could, however, lead to uncertain wrong retrospective radon exposure estimations if (210)Pb is mobile and can escape from glass, or lost as a result of cleaning-induced surface modification. This diffusion was studied by a radiotracer technique, where (209)Pb was used as a tracer in a glass matrix for which the elemental composition is known. Using the ion guide isotope separator on-line technique, the (209)Pb atoms were implanted into the glass with an energy of …

Time FactorsMaterials scienceAnnealing (metallurgy)DetergentsEnthalpyAnalytical chemistrychemistry.chemical_elementRadonIonDiffusionNuclear physicssymbols.namesakeRecoilRadiology Nuclear Medicine and imagingLead RadioisotopesRadiometryArrhenius equationModels StatisticalRadiationRadiological and Ultrasound TechnologyIsotopeTemperaturePublic Health Environmental and Occupational HealthLead RadioisotopesGeneral MedicineCyclotronschemistryRadonsymbolsGlassRadiation Protection Dosimetry
researchProduct

Modelling of combined ICRF and NBI heating in JET hybrid plasmas

2017

During the 2015-2016 JET campaigns many efforts have been devoted to the exploration of high performance plasma scenarios envisaged for ITER operation. In this paper we model the combined ICRF+NBI heating in selected key hybrid discharges using PION. The antenna frequency was tuned to match the cyclotron frequency of minority hydrogen (H) at the center of the tokamak coinciding with the second harmonic cyclotron resonance of deuterium. The modelling takes into account the synergy between ICRF and NBI heating through the second harmonic cyclotron resonance of deuterium beam ions which allows us to assess its impact on the neutron rate RNT. We evaluate the influence of H concentration which w…

TokamakQC1-999CyclotronCyclotron resonance01 natural sciences7. Clean energyFusió nuclear controlada010305 fluids & plasmaslaw.inventionlawNBI heating0103 physical sciencesNeutron010306 general physicsFusion reactionsICRF and NBI heatingJet (fluid)ICRF:Física [Àrees temàtiques de la UPC]ChemistryPhysicsPlasmaFusion powerComputational physicsJET hybrid plasmasHarmonicAtomic physicsEPJ Web of Conferences
researchProduct

Status of new 18 GHz ECRIS HIISI

2018

A new 18 GHz ECR ion source HIISI is under commissioning at the Accelerator Laboratory at the University of Jyvaskyla (JYFL). The main purpose of HIISI is to produce high-energy beam cocktails, e.g. Xe44+, for radiation effects testing of electronics with the K130 cyclotron. The initial commissioning results in 18+14 GHz operation with oxygen, argon and xenon are reported. The beam currents are compared to those produced by reference ion sources (JYFL 14 GHz ECRIS, GTS and SuSI). At the moment (October 2017) 560 µA of O6+ and 310 µA of Ar13+, for example, have been reached with HIISI at 2.3 kW total power.A new 18 GHz ECR ion source HIISI is under commissioning at the Accelerator Laboratory…

University of JyväskyläMaterials scienceCyclotrontutkimuslaitteetchemistry.chemical_elementRadiation01 natural sciences7. Clean energy010305 fluids & plasmasIonlaw.inventionNuclear physicsXenonHIISIlaw0103 physical sciencesheavy ion ion source injector010302 applied physicsArgonta114syklotronitIon sourcechemistrysäteilyfysiikkaMoment (physics)ionsaccelerator laboratoryBeam (structure)
researchProduct

Octupolar excitation of ion motion in a Penning trap: A theoretical study

2014

Abstract High-precision Penning-trap mass spectrometry uses the resonant conversion of the magnetron motional mode into the cyclotron motional mode to determine the cyclotron frequency of the ions under investigation. Usually the conversion process is performed by interaction of the ions with external quadrupolar rf-fields. Recently it was found that conversion by means of octupolar rf-fields entails a tremendous increase in mass resolution and is thus of great interest. However, the conversion results depend in an intricate way on the amplitudes and phases of the octupolar rf-field and of the motional modes of the ions. Experimental progress was hampered by the lack of an underlying theory…

Vector operatorChemistryDifferential equationEquations of motionExpectation valueCondensed Matter PhysicsJacobi elliptic functionssymbols.namesakeQuantum electrodynamicsQuantum mechanicssymbolsPhysical and Theoretical ChemistryHamiltonian (quantum mechanics)InstrumentationSpectroscopyExcitationIon cyclotron resonanceInternational Journal of Mass Spectrometry
researchProduct

Integrating analytical resolutions in non-targeted wine metabolomics

2015

Direct injection Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS), and ultra-high performance liquid chromatography coupled to mass spectrometry (UPLC/MS) were combined for the non-targeted analysis of wine metabolites. The unrivalled resolution on mass measurement allowed by the former and the separation ability of isomeric and isobaric substances by the latter, clearly increases the scope of detectable unknown metabolites in wines. Such methodology is illustrated through the comparison of chemical spaces of a young and an older Pinot noir wine. RP and HILIC chromatography could reveal up to five isomers for a given mass, throughout the explored mass range. CHO, CHOS …

WineChromatographyResolution (mass spectrometry)ChemistryHydrophilic interaction chromatographydigestive oral and skin physiologyOrganic Chemistryfood and beveragesMass spectrometryBiochemistryHigh-performance liquid chromatographyFourier transform ion cyclotron resonanceMetabolomicsDrug DiscoveryWine chemistryTetrahedron
researchProduct

Expressing forest origins in the chemical composition of cooperage oak woods and corresponding wines by using FTICR-MS.

2008

A non-targeted, ultra-high-resolution mass spectrometric, direct analysis of oak-wood extracts from two species (Quercus robur L. and Quercus petraea Liebl.) from three French forests, and of a wine aged in barrels derived therefrom has been performed to identify families of metabolites that could discriminate both the species and the geographical origin of woods. From 12 T ultra-high-resolution Fourier transform ion cyclotron resonance mass spectra of wood extracts, hundreds of mass signals were identified as possible significant biomarkers of the two species, with phenolic and carbohydrate moieties leading the differentiation between Q. robur and Q. petraea, respectively, as corroborated …

WineMagnetic Resonance SpectroscopybiologyChemistryOrganic ChemistryAnalytical chemistryWineGeneral Chemistrybiology.organism_classificationMass spectrometryMass spectrometricWoodCatalysisFourier transform ion cyclotron resonanceMass SpectrometryQuercus roburQuercusData Interpretation StatisticalBotanyMass spectrumQuercus petraeaChemical compositionChromatography High Pressure LiquidChemistry (Weinheim an der Bergstrasse, Germany)
researchProduct