Search results for "ddc:617.6"
showing 10 items of 10 documents
Soft tissue integration of different abutment surfaces: An experimental study with histological analysis
2021
OBJECTIVE To evaluate whether abutment surface and surface bio-activation have an effect on soft tissue morphogenesis. MATERIALS AND METHODS 36 patients (36 implants) were included. Abutments were randomly divided into 4 groups (n = 9): Smooth Surface-MAChined (MAC), Ultrathin Threaded Microsurface (UTM), MAC Plasma of Argon activated (Plasma-MAC), and UTM Plasma of Argon activated (Plasma-UTM). After 2 months of healing, soft tissue samples were collected and prepared for histological analysis. The margin of the peri-implant mucosa (PM), the apical extension of the barrier epithelium (aJE), and the apical location of the abutment (AM) were identified. Significances of differences among gro…
Luting of ceramic crowns with a self-adhesive cement: Effect of contamination on marginal adaptation and fracture strength
2012
Objectives: This study evaluated the percentages of continuous margins (%CM) and fracture strength (FS) of crowns made out from blocs of leucite-reinforced ceramic (IPS Empress CAD) and luted with a representative self-adhesive cement (RelyX Unicem) under four contaminating agents: saliva, water, blood, a haemostatic solution containing aluminium chloride (pH= 0.8) and a control group with no contamination. Study Design: %CM at both tooth-cement (TC) and cement-crown (CC) interfaces were determined before and after a fatigue test consisting of 600’000 chewing loads and 1’500 temperature cycles changing from 5º C to 50º C. Load to fracture was recorded on fatigued specimens. Kruskal-Wallis t…
Oral health-related quality of life and clinical outcomes of immediately or delayed loaded implants in the rehabilitation of edentulous jaws: A retro…
2018
Background Patient-centered outcomes are being given great attention by the dental scientific community. The Oral Health Impact Profile -14 questionnaire (OHIP-14) has been introduced to address patients' success criteria when describing the impact of oral rehabilitations on quality of life (OHrQoL). Methods Thirty-five patients wearing a full-arch implant-prosthesis being in place between 4 and 6 years before this analysis were considered eligible and then enrolled in the present retrospective study. According to their prosthetic anamnesis, two groups were defined: delayed loading group (IL-group) and immediate loading group (IL-group). At the moment of analysis, clinical and radiographic …
Small-diameter titanium Grade IV and titanium-zirconium implants in edentulous mandibles: three-year results from a double-blind, randomized controll…
2015
OBJECTIVE: The aim of this study was to compare crestal bone-level changes, soft tissue parameters and implant success and survival between small-diameter implants made of titanium/zirconium (TiZr) alloy or of Grade IV titanium (Ti) in edentulous mandibles restored with removable overdentures. MATERIALS AND METHODS: This was a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann bone-level implants (diameter 3.3 mm), one of Ti Grade IV (control) and one of TiZr (test), in the interforaminal region. Implants were loaded after 6-8 weeks and removable Locator-retained overdentures were placed within 2 weeks of l…
Small-diameter titanium grade IV and titanium-zirconium implants in edentulous mandibles: five-year results from a double-blind, randomized controlle…
2015
BACKGROUND The aim of this study was to compare the 5-year survival and success rates of 3.3 mm dental implants either made from titanium-zirconium (TiZr) alloy or from Grade IV titanium (Ti Grade IV) in mandibular implant-based removable overdentures. METHODS The core study had a follow-up period of 36 months and was designed as a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann Bone Level implants (diameter 3.3 mm, SLActive®), one of TiZr (test) and one of Ti Grade IV (control), in the interforaminal region. This follow-up study recruited patients from the core study and evaluated the plaque and sulcus …
Drugs and diseases: Summary and consensus statements of group 1. The 5th EAO Consensus Conference 2018
2018
OBJECTIVES: The task of this working group was to update the knowledge about the use of drugs and biologicals affecting healing of soft tissue and bone during implant treatment or procedures associated with it. Moreover, the impact of titanium particles and biocorrosion on complications and implant survival has been analysed. MATERIALS AND METHODS: The literature in the areas of interest (platelet concentrates, antiresorptive drugs as well as implant-host interaction) was screened using systematic reviews for the former two areas, whereas a narrative critical review was performed for the latter topic. Two manuscripts on platelet concentrates, one manuscript on antiresorptive drugs and one m…
Minimally invasive prosthetic procedures in the rehabilitation of a bulimic patient affected by dental erosion
2015
The population affected by dental erosion due to bulimia is generally very young. This population group has a high aesthetic requirement; the dentition in these patients is severely damaged, especially in the anterior maxillary quadrant. In terms of treatment, it is still controversial whether an adhesive rehabilitation is preferable to a longer-lasting but more aggressive conventional treatment, such as full-crown coverage of the majority of teeth. This case report describes the prosthetic rehabilitation of a young female patient previously affected by bulimia nervosa and presenting erosion of the maxillary teeth. The prosthetic rehabilitation was performed through indirect adhesive restor…
A Double-Blind Randomized Controlled Trial (RCT) of Titanium-13Zirconium versus Titanium Grade IV Small-Diameter Bone Level Implants in Edentulous Ma…
2012
Background: The use of endosseous dental implants has become common practice for the rehabilitation of edentulous patients, and a two-implant overdenture has been recommended as the standard of care. The use of small-diameter implants may extend treatment options and reduce the necessity for bone augmentation. However, the mechanical strength of titanium is limited, so titanium alloys with greater tensile and fatigue strength may be preferable. Purpose: This randomized, controlled, double-blind, multicenter study investigated in a split-mouth model whether small-diameter implants made from Titanium-13Zirconium alloy (TiZr, Roxolid™) perform at least as well as Titanium Grade IV implants. Me…
Bulk filling of Class II cavities with a dual-cure composite: Effect of curing mode and enamel etching on marginal adaptation.
2014
Objectives: This study attempted to find a simple adhesive restorative technique for class I and II cavities on posterior teeth. Study Design: The tested materials were a self-etching adhesive (Parabond, Coltene/Whaledent) and a dual-cure composite (Paracore, Coltene/Whaledent) used in bulk to restore the cavities. Class II MO cavities were performed and assigned to 4 groups depending on the orthophosphoric acid (H3PO4) conditioning of enamel and polymerization method used (chemical or dual). Specimens were subjected to quantitative marginal analysis before and after thermo-mechanical loading. Results: Higher percentages of marginal adaptation at the total margin length, both before and aft…
Development of a European consensus from dentists, dental hygienists and physicians on a standard for oral health care in care-dependent older people…
2020
ObjectivesThis study aimed to obtain a consensus on oral health policy, access to dental care, oral hygiene measures and training levels.BackgroundPoor oral health is widespread in care-dependent older people, but no consensus for a minimum standard of oral health care exists yet.MethodsThe e-Delphi approach was applied to a selected panel of interdisciplinary experts. Data analysis was based on three measurements: (a) ≥70% of experts’ opinion fall into category “agree or strongly agree,” (b) median score on the 5-point Likert scale ≥4, (c) interquartile range ≤1.ResultsA total of 31 experts from 17 European countries participated in this survey. Agreement was achieved for a compulsory dent…