Search results for "defocus"

showing 10 items of 14 documents

Influence of different types of astigmatism on visual acuity

2016

[EN] Purpose To investigate the change in visual acuity (VA) produced by different types of astigmatism (on the basis of the refractive power and position of the principal meridians) on normal accommodating eyes. Methods The lens induced method was employed to simulate a set of 28 astigmatic blur conditions on different healthy emmetropic eyes. Additionally, 24 values of spherical defocus were also simulated on the same eyes for comparison. VA was measured in each case and the results, expressed in logMAR units, were represented against of the modulus of the dioptric power vector (blur strength). Results LogMAR VA varies in a linear fashion with increasing astigmatic blur, being the slope o…

AdultMaleVisual acuityVisual acuityAstigmatismoEstado de acomodaciónAstigmatismAgudeza visual03 medical and health sciences0302 clinical medicinelcsh:Ophthalmologymedicinelcsh:QC350-467HumansAgudeza visualAccommodation OcularAstigmatismmedicine.diseaseEyeglassesReadingEjelcsh:RE1-994Defecto esféricoFISICA APLICADA030221 ophthalmology & optometryOptometryAccommodation stateOriginal ArticleFemalemedicine.symptomSpherical defocusAxisPsychologylcsh:Optics. Light030217 neurology & neurosurgeryOptometry
researchProduct

Human eyes do not need monochromatic aberrations for dynamic accommodation

2017

Purpose To determine if human accommodation uses the eye's own monochromatic aberrations to track dynamic accommodative stimuli. Methods Wavefront aberrations were measured while subjects monocularly viewed a monochromatic Maltese cross moving sinusoidally around 2D of accommodative demand with 1D amplitude at 0.2 Hz. The amplitude and phase (delay) of the accommodation response were compared to the actual vergence of the stimulus to obtain gain and temporal phase, calculated from wavefront aberrations recorded over time during experimental trials. The tested conditions were as follows: Correction of all the subject's aberrations except defocus (C); Correction of all the subject's aberratio…

AdultMaledirectional cuesgenetic structuresVisual AcuityRefraction Ocular01 natural sciencesdynamic accommodation010309 opticsYoung Adult03 medical and health sciences0302 clinical medicineOpticsmonochromatic aberrations0103 physical sciencesHumansWavefrontPhysicsdefocusbusiness.industryAccommodation OcularAstigmatismOriginal ArticlesConvergence Oculareye diseasesSensory SystemsOphthalmologySpherical aberrationAmplitude030221 ophthalmology & optometryFemaleOriginal Articlesense organsMonochromatic colorbusinessAccommodationPhotic StimulationOptometryOphthalmic and Physiological Optics
researchProduct

Real metrology by using depth map information

2004

Usually in an image no real information about the scene’s depth (in terms of absolute distance) is available. In this paper, a method that extracts real depth measures is developed. This approach starts considering a region located in the center of the depth map. This region can be positioned, interactively, in any part of the depth map in order to measure the real distance of every object inside the scene. The histogram local maxima of this region are determined. Among these values the biggest, that represents the gray-level of the most considerable object, is chosen. This gray-level is used in an exponential mapping function that converts, using the input camera settings, the depth map gr…

Depth from defocusComputer sciencebusiness.industryComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONFunction (mathematics)Object (computer science)Measure (mathematics)Image (mathematics)MetrologyDepth mapComputer Science::Computer Vision and Pattern RecognitionHistogramComputer visionArtificial intelligencebusiness
researchProduct

Spectral dependence of purely-Kerr driven filamentation in air and argon

2010

5 pags, 4 figs.-- PACS number(s): 42.65.Jx, 42.65.Tg, 78.20.Ci. -- Publisher error corrected 27 September 2010, Erratum Phys. Rev. A 82, 039905 (2010): https://doi.org/10.1103/PhysRevA.82.033826

Kerr effect[ PHYS.PHYS.PHYS-ATOM-PH ] Physics [physics]/Physics [physics]/Atomic Physics [physics.atom-ph]chemistry.chemical_elementFOS: Physical sciencesPhysics::Opticsddc:500.201 natural sciencesLaser filamentationSpectral line010309 opticsFilamentationPhysics::Plasma PhysicsIonizationSelf-focusing0103 physical sciencesSelf focusing and defocusingOptical solitonsOptical constantsUltrafast nonlinear optics010306 general physicsSelf-phase modulationOptical Kerr effectPhysicsArgonMolecular alignment[PHYS.PHYS.PHYS-ATOM-PH]Physics [physics]/Physics [physics]/Atomic Physics [physics.atom-ph]Femtosecond phenomena42.65.Jx 42.65.Tg 78.20.CiSelf-focusingSelf-phase modulationBeam trappingAtomic and Molecular Physics and OpticsWavelengthchemistryPlasmasAtomic physicsPhysics - OpticsOptics (physics.optics)
researchProduct

Agent defocusing in two-participant clauses in Finnish Sign Language

2019

This article investigates what strategies are used for defocusing the agent in two-participant clauses in FinSL. The question is approached by analyzing a set of data that consists of videotaped informational texts. Several strategies for agent defocusing were found. First, the agent can simply be omitted. Second, the agent can be expressed with a pronominal pointing sign used non-referentially. Pronominal pointing signs that can be used non-referentially include at least the non-first person plural pronominal pointing sign and the first person singular pointing sign, possibly also the first person plural pointing sign. This study also suggests that constructed action is an additional, opti…

Linguistics and LanguageVerbContext (language use)Sign languagelausetyypitLanguage and Linguisticsconstructed actionviittomakielipronominal pointing signsomissionagent defocusingpassiiviSet (psychology)PluralLanguage. Linguistic theory. Comparative grammarP101-410passiveAgent defocusing; passive; Finnish Sign Language; omission; pronominal pointing signs; constructed actionLinguisticsviittomatlinguistics sign language linguisticsAntecedent (grammar)Action (philosophy)Agent defocusingsuomalainen viittomakieliPsychologyFinnish Sign LanguageSign (mathematics)
researchProduct

Robust Depth Estimation for Light Field Microscopy

2019

Light field technologies have seen a rise in recent years and microscopy is a field where such technology has had a deep impact. The possibility to provide spatial and angular information at the same time and in a single shot brings several advantages and allows for new applications. A common goal in these applications is the calculation of a depth map to reconstruct the three-dimensional geometry of the scene. Many approaches are applicable, but most of them cannot achieve high accuracy because of the nature of such images: biological samples are usually poor in features and do not exhibit sharp colors like natural scene. Due to such conditions, standard approaches result in noisy depth ma…

MicroscopemicroscopeComputer scienceComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISION02 engineering and technologylcsh:Chemical technologyBiochemistryArticleAnalytical Chemistrylaw.inventionsymbols.namesakelawDepth mapMicroscopy0202 electrical engineering electronic engineering information engineeringdepth estimationlight fieldlcsh:TP1-1185Computer visionElectrical and Electronic Engineeringstereo matchingInstrumentationLight field microscopydefocusbusiness.industryÒptica021001 nanoscience & nanotechnologyAtomic and Molecular Physics and OpticsField (geography)MicroscòpiaFourier transformsymbols020201 artificial intelligence & image processingArtificial intelligenceNoise (video)0210 nano-technologybusinessLight fieldSensors
researchProduct

Visual Acuity in Myopes with Standard and Reversed Contrast Optotypes

2017

Abstract The aim of this study was to assess the visual acuity of myopes with standard and reversed contrast optotypes and to determine how the visual acuity of myopes is affected by optical defocus and the type of optical correction, either contact lenses or spectacles. Twenty-three myopic subjects (18 and 23 years old) with uncorrected vision had their visual acuity assessed with both standard and reversed contrast optotypes. The study also included 10 myopes with contact lens as well as habitual spectacle correction. The visual acuity for myopes with uncorrected vision was better with reversed than standard contrast optotypes. Better reversed contrast than standard contrast visual acuity…

MultidisciplinaryVisual acuityGeneral interestgenetic structuresvisual acuitymedia_common.quotation_subjectScienceQcontrasteye diseasesmedicineoptical correctionOptometryContrast (vision)sense organsmyopiamedicine.symptomoptical defocusmedia_commonProceedings of the Latvian Academy of Sciences. Section B, Natural Sciences
researchProduct

Through-focus response of multifocal intraocular lenses evaluated with a spatial light modulator

2012

A new testing technique based on the use of a liquid crystal spatial light modulator (SLM) is proposed to analyze the optical quality of multifocal intraocular lenses (MIOLs). Different vergences and decentrations of the incident beam can be programmed onto the SLM in order to record the point spread function (PSF) for different object positions. From these axial PSFs, the through-focus modulation transfer function is computed. Because there are no moving parts in the experimental setup, this method is fast and versatile to assess MIOLs. Experimental results confirm the potential of the proposed method.

Point spread functionMaterials scienceImage qualityProsthesis DesignOpticsIn-vivoOptical transfer functionDefocus transfer-functionImage qualityDecentrationElectrical and Electronic EngineeringEngineering (miscellaneous)LightingTiltLenses IntraocularSpatial light modulatorbusiness.industryOptical-performanceMultifocal intraocular lensAtomic and Molecular Physics and OpticsEquipment Failure AnalysisRefractometryAberrationsTilt (optics)DesignsFISICA APLICADASpatial frequencybusinessFocus (optics)Applied Optics
researchProduct

A novel 3D recovery method by dynamic (de)focused projection

2011

This paper presents a novel 3D recovery method based on structured light. This method unifies depth from focus (DFF) and depth from defocus (DFD) techniques with the use of a dynamic (de)focused projection. With this approach, the image acquisition system is specifically constructed to keep a whole object sharp in all of the captured images. Therefore, only the projected patterns experience different defocused deformations according to the object’s depths. When the projected patterns are out of focus, their Point Spread Function (PSF) is assumed to follow a Gaussian distribution. The final depth is computed by the analysis of the relationship between the sets of PSFs obtained from different…

Range sensor[INFO.INFO-OH] Computer Science [cs]/Other [cs.OH]FocusDepth from defocusPas de mot clé en françaisBlur estimation3D reconstructionActive illumination pattern
researchProduct

Influencia de los diferentes tipos de astigmatismo en la agudeza visual

2017

[EN] Purpose To investigate the change in visual acuity (VA) produced by different types of astigmatism (on the basis of the refractive power and position of the principal meridians) on normal accommodating eyes. Methods The lens induced method was employed to simulate a set of 28 astigmatic blur conditions on different healthy emmetropic eyes. Additionally, 24 values of spherical defocus were also simulated on the same eyes for comparison. VA was measured in each case and the results, expressed in logMAR units, were represented against of the modulus of the dioptric power vector (blur strength). Results LogMAR VA varies in a linear fashion with increasing astigmatic blur, being the slope o…

Visual acuityEjeDefecto esféricoFISICA APLICADAAstigmatismAccommodation stateAstigmatismoEstado de acomodaciónSpherical defocusAxisAgudeza visual
researchProduct