Search results for "dental abutments"

showing 10 items of 38 documents

Implant-supported metal-ceramic and resin-modified ceramic crowns: A 5-year prospective clinical study.

2018

Abstract Statement of problem Because of market demand for innovation, new restoration materials have been introduced without adequate testing; clinical failure may be the consequence, and clinical studies are needed. Purpose The purpose of this clinical study was to evaluate the biological and mechanical clinical behavior of implant-supported resin-modified ceramic crowns compared with that of metal-ceramic crowns. Material and methods Forty-two participants aged between 35 and 65 years received single implants in posterior edentulous sites. After the osseointegration period, half of the implants (selected randomly) (n=25) were restored with metal-ceramic crowns (MC group) and the other ha…

Ceramicsmedicine.medical_treatmentDentistryDental AbutmentsCrown (dentistry)Osseointegration03 medical and health sciences0302 clinical medicineDental porcelainstomatognathic systemDental AbutmentsmedicineCeramicDental Restoration FailureProspective StudiesSurvival rateDental ImplantsCrownsbusiness.industryDental prosthesis030206 dentistryDental PorcelainMetalsvisual_artvisual_art.visual_art_mediumImplantDental Prosthesis Implant-SupportedZirconiumOral SurgerybusinessThe Journal of prosthetic dentistry
researchProduct

The influence of platform switching in dental implants. A literature review.

2010

Introduction: The platform switching concept involves the reduction of the restoration abutment diameter with respect to the diameter of the dental implant. In 1991, dental implants of 5 and 6 mm diameter platforms were introduced. However, matching-diameter prosthetic abutments were not available. These implants were restored with “standard”-diameter prosthetic components (4,1 mm). Long-term follow up around these wide-platforms showed higher levels of bone preservation. In time, it has been called platform switching. The first case report applying this concept was indexed in MedLine in 2005. Materials and Methods: The aim of this article is to carry out a literature review of articles whi…

Dental ImplantsCrestal boneBone preservationbusiness.industryComputer sciencemedicine.medical_treatmentPlatform switchingMEDLINEAbutmentDentistryDental AbutmentsOtorhinolaryngologyDental AbutmentsmedicineHumansSurgerybusinessDental implantGeneral DentistryReduction (orthopedic surgery)Medicina oral, patologia oral y cirugia bucal
researchProduct

Tooth-implant connection in removable denture.

2016

When the patient cannot be rehabilitated with a fixed denture, or when he does not succeed in adapting to a traditional removable denture, a possible alternative solution consists in the use of a limited number of implants, placed in strategic positions in the arches of the patient, and subsequently connected to their residual teeth. The aim of this review is to evaluate the progress made on connections between teeth and implants in removable denture, to analyze their advantages and disadvantages and to compare the survival rate, both of the teeth and of the implants used as abutments, present in the various studies taken into examination, with the aim of being able to evaluate the effectiv…

Dental ImplantsCrownsJaw Edentulous PartiallyDental AbutmentsDenture OverlayDental implants - Denture partial removable - Survival rateOtorhinolaryngologyDental Prosthesis DesignSettore MED/28 - Malattie OdontostomatologicheQuality of LifeDenture Partial RemovableHumansSurgeryEquipment FailureDental Prosthesis Implant-SupportedStress MechanicalOral SurgeryDenture DesignMinerva stomatologica
researchProduct

Impact of abutment geometry on early implant marginal bone loss. A double‐blind, randomized, 6‐month clinical trial

2022

Objectives The objective of this study was to analyze the impact of the abutment width on early marginal bone loss (MBL). Material and Methods A balanced, randomized, double-blind clinical trial with two parallel experimental arms was conducted without a control group. The arms were “cylindrical” abutment and “concave” abutment. Eighty hexagonal internal connection implants, each with a diameter of 4 × 10 mm, were placed in healed mature bone. The main variable was the peri-implant tissue stability, which was measured as MBL at 8 weeks and 6 months. Results The final sample consisted of 77 implants that were placed in 25 patients. 38 (49.4%) were placed using the cylindrical abutment, and t…

Dental Implantsdental implantprostheses abutment widthDental Implantation EndosseousAlveolar Bone LossDental AbutmentsDental Implant-Abutment DesignUNESCO::CIENCIAS TECNOLÓGICASearly marginal bone lossrandomized clinical trialDental Implants Single-Toothsingle toothHumansOral SurgeryClinical Oral Implants Research
researchProduct

Survival rates of a lithium disilicate-based core ceramic for three-unit esthetic fixed partial dentures: a 10-year prospective study.

2013

Purpose The aim of this prospective study was to evaluate the clinical efficacy and long-term survival rate of three-unit fixed partial dentures (FPDs) made from lithium disilicate-based core ceramic. Materials and methods Twenty-one three-unit FPDs were placed in 19 patients to replace single lost teeth in the esthetic area, following a study protocol that took clinical, esthetic, and radiologic aspects into consideration. Each case was reviewed at 1 week following placement, at 6 months, and then annually for 10 years. Statistical analysis was performed using Kaplan-Meier survival analysis. Results Out of the 19 patients, 14.3% presented reversible postoperative sensitivity. Recession was…

Dental Restoration FailureMaleCeramicsSurface PropertiesDentistryColorDental AbutmentsDental bondingDental CariesEsthetics DentalDental AbutmentsOcclusionMedicineHumansGingival RecessionDental Restoration FailureLongitudinal StudiesProspective StudiesProspective cohort studyDenture DesignSurvival rateSurvival analysisbusiness.industryDental Plaque IndexDental BondingGeneral MedicineDentin SensitivityMiddle AgedTooth Preparation ProsthodonticDental PorcelainSurvival AnalysisDental Plaque IndexTreatment OutcomeLithium CompoundsDenture Partial FixedFemaleOral SurgeryPeriodontal IndexbusinessFollow-Up StudiesThe International journal of prosthodontics
researchProduct

Support of removable partial dentures in situations with a unilaterally missing canine and a curved edentulous ridge.

1997

The load and movement of abutments and removable partial dentures were examined in situations with a unilaterally missing canine and a curved edentulous ridge. These measurements were performed on a model adapted to intraoral conditions. In this simulation, removable partial dentures supported by incisors may result in failure. Spring rest support results in significantly reduced articulation vertically and horizontally when compared with solid rest support and avoids periodontal overloading.

Dental Stress AnalysisCuspidDenture BasesComputer sciencemedicine.medical_treatmentDentistryDental AbutmentsIncisorDental AbutmentsmedicineMaxillaHumansRest (music)OrthodonticsAnalysis of Variancebusiness.industryJaw Edentulous PartiallyRidge (differential geometry)Denture RetentionIncisormedicine.anatomical_structureDental Stress AnalysisDenture baseDenture Partial RemovableOral SurgeryDenturesbusinessThe Journal of prosthetic dentistry
researchProduct

Mechanical resistance of zirconium implant abutments: A review of the literature

2010

The increase of aesthetic demands, together with the successful outcome of current implants, has renewed interest in the search for new materials with enough mechanical properties and better aesthetic qualities than the materials customarily used in implanto-prosthetic rehabilitation. Among these materials, zirconium has been used in different types of implants, including prosthetic abutments. The aim of the present review is to analyse current scientific evidence supporting the use of this material for the above mentioned purposes. We carried out the review of the literature published in the last ten years (2000 through 2010) of in vitro trials of dynamic and static loading of zirconium ab…

Dental Stress AnalysisFracture strengthAbutmentNew materialschemistry.chemical_elementDentistryDental AbutmentsDental MaterialsDental AbutmentsMaterials TestingMedicineCyclic loadingHumansZirconium abutmentGeneral DentistryStatic loadingZirconiumbusiness.industryMechanical resistance:CIENCIAS MÉDICAS [UNESCO]Zirconium implant abutmentOtorhinolaryngologychemistryUNESCO::CIENCIAS MÉDICASFracture resistanceSurgeryResearch-ArticleCyclic loadingImplantZirconiumOral Surgerybusiness
researchProduct

Comparative fracture behavior of monolithic and veneered zirconia posterior fixed dental prostheses

2017

The purpose of this study was to evaluate and to compare the fracture load and the fracture pattern of monolithic and veneered zirconia posterior fixed dental prostheses (FDPs). Twenty standardized steel dies were prepared to receive posterior 3-unit FDPs. Specimens were randomly divided into 2 groups (n=10): (1) Lava Zirconia, and (2) Lava Plus. All FDPs were cemented using glass ionomer cement and subjected to thermal and mechanical cycling at 5-55ºC with a 30-s dwell time for 120,000 masticatory cycles. All specimens were subjected to a three-point bending test until fracture. Data were statistically analyzed using Student's t test, paired t-test and Weibull statistics (α=0.05). No diffe…

Dental Stress AnalysisMaterials scienceGlass ionomer cementDentistryDental Abutments02 engineering and technologyBendingVeneering ceramicDental Materials03 medical and health sciences0302 clinical medicineMaterials TestingCubic zirconiaDental Restoration FailureGeneral Dentistrybusiness.industryFracture loadMonolithic zirconia030206 dentistryStainless Steel021001 nanoscience & nanotechnologyDental VeneersGlass Ionomer CementsCeramics and CompositesFracture (geology)Computer-Aided DesignDenture Partial FixedZirconium0210 nano-technologybusinessDental Materials Journal
researchProduct

Effect of Thermomechanical and Static Loading on the Load to Fracture of Metal‐Ceramic, Monolithic and Veneered Zirconia Posterior Fixed Partial Dent…

2018

PURPOSE To evaluate the influence of static (not preloaded) and thermomechanical loading on the load to fracture of metal-ceramic, monolithic and veneered zirconia computer-aided design/computer-aided manufacturing (CAD/CAM) posterior fixed partial dentures (FPDs). MATERIALS AND METHODS One hundred standardized specimens with 2 abutments screwed onto a platform were prepared from stainless steel to receive a posterior 3-unit FPD with an intermediate pontic. Specimens were randomly divided into 5 groups (n = 20): Metal-ceramic (control group), Lava Zirconia system, Vita In-Ceram YZ, IPS e.max ZirCAD, and Lava Plus. Half of the specimens of each group (n = 10) underwent no preloading, and the…

Dental Stress AnalysisMaterials scienceMetal Ceramic AlloysDental Abutments02 engineering and technologyCrossheadDental MaterialsRandom Allocation03 medical and health sciences0302 clinical medicineMaterials TestingFixed partial denturesCubic zirconiaDental Restoration FailureComposite materialGeneral DentistryUniversal testing machineFracture loadMonolithic zirconia030206 dentistryStainless Steel021001 nanoscience & nanotechnologyMetal ceramicDental VeneersFracture (geology)Computer-Aided DesignDenture Partial FixedStress MechanicalZirconium0210 nano-technologyJournal of Prosthodontics
researchProduct

Fracture resistance after implantoplasty in three implant-abutment connection designs

2020

Background To assess the effect of implantoplasty and implant-abutment design on the fracture resistance and macroscopic morphology of narrow-diameter (3.5 mm) dental implants. Material and Methods Screw-shaped titanium dental implants (n = 48) were studied in vitro. Three groups (n = 16) were established, based on implant-abutment connection type: external hexagon, internal hexagon and conical. Eight implants from each group were subjected to an implantoplasty procedure; the remaining 8 implants served as controls. Implant wall thickness was recorded. All samples were subjected to a static strength test. Results The mean wall thickness reductions varied between 106.46 and 153.75 µm. The me…

Dental Stress AnalysisTitanium implantMaterials scienceCirurgia dentalchemistry.chemical_elementDental Abutments03 medical and health sciences0302 clinical medicineFlexural strengthDental AbutmentsMaterials TestingGeneral DentistryEndosseous dental implantsDental ImplantsTitaniumOrthodonticsCrownsResearchConnection (principal bundle)030206 dentistry:CIENCIAS MÉDICAS [UNESCO]OtorhinolaryngologychemistryDental surgeryUNESCO::CIENCIAS MÉDICASFracture (geology)SurgeryImplants dentals intraossisImplantImplantologyImplant abutmentTitanium
researchProduct