Search results for "dental prosthesis"
showing 10 items of 135 documents
A prospective, multi-center, practice-based cohort study on all-ceramic crowns
2021
The aim of this prospective, multi-center, practice-based cohort study was to analyze factors associated with the success of all-ceramic crowns.All-ceramic crowns placed in a practice-based research network ([Ceramic Success Analysis, AG Keramik) were analyzed. Data from 1254 patients with (mostly in-office CAD/CAM) all-ceramic crowns placed by 101 dentists being followed up for more than 5 years were evaluated. At the last follow-up visit crowns were considered as successful (not failed) if they were sufficient, whereas crowns were considered as survived (not lost) if they were still in function. Multi-level Cox proportional hazards models were used to evaluate the association between a ra…
Implant-supported metal-ceramic and resin-modified ceramic crowns: A 5-year prospective clinical study.
2018
Abstract Statement of problem Because of market demand for innovation, new restoration materials have been introduced without adequate testing; clinical failure may be the consequence, and clinical studies are needed. Purpose The purpose of this clinical study was to evaluate the biological and mechanical clinical behavior of implant-supported resin-modified ceramic crowns compared with that of metal-ceramic crowns. Material and methods Forty-two participants aged between 35 and 65 years received single implants in posterior edentulous sites. After the osseointegration period, half of the implants (selected randomly) (n=25) were restored with metal-ceramic crowns (MC group) and the other ha…
Prosthetically‐Driven Full‐Mouth Implant‐Supported Prostheses Using Guided Surgical Implant Planning with Composite Resin Markers: A Case Report
2021
This report describes a prosthetically-driven implant planning method, guided by the alignment procedures between the cone beam computed tomography, intraoral digital scans, and digitized maxillary and mandibular interim complete dentures using intraoral composite resin markers as a common reference. The markers were attached to the keratinized oral mucosa of the edentulous ridges using cyanoacrylate and kept in place during the digitizing procedures. The technique provides a simpler and more economical alternative to conventional prosthetically-driven static implant planning methods.
Peri-implant parameters in head and neck reconstruction: influence of extraoral skin or intraoral mucosa.
2009
Objective: This study is designed to assess dental implants supporting overdentures in edentulous patients with operated head and neck malignancies using parameters to detect peri-implant disease. Material and methods: Thirty-four implants supporting overdentures in 34 oral cancer patients were examined. Clinical parameters [plaque index, probing depth, bleeding on probing (BOP), origin of peri-implant soft tissue, and amount of irradiation] were recorded, and microbiological identification of periodontal pathogens was carried out by DNA–DNA hybridization. To identify yeast species, the samples were cultivated on Sabouraud agar plates and subsequently identified by API 20C AUX plates. An im…
Narrow-diameter implants: A systematic review and meta-analysis.
2018
OBJECTIVES Narrow-diameter implants (NDI) are claimed to be a reasonable alternative to bone augmentation procedures. The aim of this comprehensive literature review was to conduct a meta-analysis comparing the implant survival of NDI and standard diameter implants (SDI) and to provide recommendations and guidelines for application of NDI. MATERIAL AND METHODS An extensive systematic literature search was performed in the PubMed/MEDLINE and the Cochrane Library databases. NDI were classified into Category 1 (implant diameter <3.0 mm, "mini-implants"), Category 2 (implant diameter 3-3.25 mm) and Category 3 (implant diameters 3.3-3.5 mm). Clinical studies at all levels of evidence with at lea…
Treatment concepts of horizontally deficient ridges-A retrospective study comparing narrow-diameter implants in pristine bone with standard-diameter …
2021
OBJECTIVES To compare clinical and radiological outcomes of narrow-diameter implants (NDI) placed in pristine bone to standard-diameter implants placed in combination with horizontal bone augmentation procedures (SDI+A) for horizontally deficient alveolar ridges. MATERIAL AND METHODS For this retrospective study, the outcome of 597 NDI (∅ 3.3 mm, 272 patients), inserted in pristine bone, were compared with 180 SDI (∅ 4.1 mm, 83 patients), inserted in combination with horizontal augmentation procedures. Oral health-related quality of life was assessed in patients available for recall. RESULTS After a mean follow-up of 37.6 ± 40 months for the NDI and of 42.4 ± 49 months for the SDI+A, surviv…
Effects of minute misregistrations of prefabricated markers for image-guided dental implant surgery: an analytical evaluation
2012
Objectives The goal of the present study was to develop a theoretical analysis of errors in implant position, which can occur owing to minute registration errors of a reference marker in a cone beam computed tomography volume when inserting an implant with a surgical stent. Material and methods A virtual dental-arch model was created using anatomic data derived from the literature. Basic trigonometry was used to compute effects of defined minute registration errors of only voxel size. The errors occurring at the implant's neck and apex both in horizontal as in vertical direction were computed for mean ±95%-confidence intervals of jaw width and length and typical implant lengths (8, 10 and 1…
Tooth-implant connection in removable denture.
2016
When the patient cannot be rehabilitated with a fixed denture, or when he does not succeed in adapting to a traditional removable denture, a possible alternative solution consists in the use of a limited number of implants, placed in strategic positions in the arches of the patient, and subsequently connected to their residual teeth. The aim of this review is to evaluate the progress made on connections between teeth and implants in removable denture, to analyze their advantages and disadvantages and to compare the survival rate, both of the teeth and of the implants used as abutments, present in the various studies taken into examination, with the aim of being able to evaluate the effectiv…
Topographic characterisation of dental implants for commercial use.
2016
Background To characterize the surface topography of several dental implants for commercial use. Material and Methods Dental implants analyzed were Certain (Biomet 3i), Tissue Level (Straumann), Interna (BTI), MG-InHex (MozoGrau), SPI (Alphabio) and Hikelt (Bioner). Surface topography was ascertained using a confocal microscope with white light. Roughness parameters obtained were: Ra, Rq, Rv, Rp, Rt, Rsk and Rku. The results were analysed using single-factor ANOVA and Student-Neuman-Keuls(p<0.05) tests. Results Certain and Hikelt obtained the highest Ra and Rq scores, followed by Tissue Level. Interna and SPI obtained lower scores, and MG-InHex obtained the lowest score. Rv scores followed …
A Prospective Noninterventional Study to Evaluate Survival and Success of Reduced Diameter Implants Made From Titanium-Zirconium Alloy
2015
Narrow diameter implants may be at increased risk of overload due to occlusal forces; therefore, implants with higher fatigue strength may be beneficial. The aim of this observational study was to evaluate survival and success of narrow diameter (Ø 3.3 mm) TiZr alloy (Roxolid, Institut Straumann AG, Basel, Switzerland) implants for 2 years in daily dental practice. This was a prospective, non-interventional, multicenter study; no specific patient inclusion or exclusion criteria were applied. Each patient received at least one TiZr implant; the treatment plan, including implant loading and final restoration, was at the investigator's discretion. The primary outcome was implant survival and s…