Search results for "design."
showing 10 items of 5715 documents
Cutting efficiency of heat-treated nickel-titanium single-file systems at different incidence angles.
2020
Cutting efficiency of Reciproc R25 (REC) and Reciproc blue R25 (REB) at different inclinations was evaluated. Sixty new files were tested at 90°, 70° and 45° of inclination in relation to the sample (n = 10), using a customised machine. All files were activated in reciprocation against standardised gypsum blocks for 120 s. Cutting efficiency was determined by measuring the block weight loss with an analytical balance and measuring the length of the block surface cut using a digital calliper. Data were statistically analysed (two-way ANOVA, Bonferroni t-test) with the significance level set at P < 0.05. There was no difference for REC among the tested angles. REB had no statistical differenc…
Length of endodontic files measured in digital radiographs with and without noise-suppression filters: an ex-vivo study
2011
The aim of this study is to evaluate if theoretically possible edge shifts induced by noise-suppression filters potentially occur on objects found in digital radiographs. Most manufacturers carry out noise-suppression filtering of their images before they are displayed to the user. It is not usually possible for the user to disrupt the function of the filters. The use of these filters can lead to deletion of small image structures.K-files (ISO size 06, 08, 10 and 15) were placed in the root canals of 6 human teeth located in cadaver jaw segments. File tip positions were measured on original and filtered digital images by three observers. The file position was marked on each filtered image a…
Electrochemical corrosion assessment of RaCe and Mtwo rotary nickle-titanium instruments after clinical use and sterilization
2010
Aim: The aim of the present study was to electrochemically evaluate corrosion resistance of RaCe and Mtwo files after repeated sterilization and preparation procedures. Study Design: A total of 450 rotary files were used. In the working groups, 72 files from each file type were distributed into 4 groups. RaCe and Mtwo files were used to prepare one root canal of the mesial root of extracted human mandibular first molars. The procedure was repeated to prepare 2 to 8 canals. The following irrigation solutions were used: group 1, RaCe files with 2.5% NaOCl; group 2, RaCe files with normal saline; group 3, Mtwo files with 2.5% NaOCl; and group 4, Mtwo files with normal saline in the manner desc…
A prospective evaluation of zirconia anterior partial fixed dental prostheses: Clinical results after seven years.
2014
Abstract Statement of problem Because of the high mechanical strength of zirconium dioxide, the metal in fixed partial prostheses can now be replaced. However, the material is susceptible to aging or hydrothermal degradation and to chipping of the feldspathic veneer. Purpose The purpose of this prospective study was to evaluate the survival (without failure) and success (survival without any complication or failure) rate and clinical efficacy of anterior zirconia partial fixed dental prostheses. Material and methods Twenty-seven anterior partial fixed dental prostheses of 3 to 6 units were fabricated. All participants were examined after 1 month and 6 months, then annually for 7 years. Resu…
Survival rates of a lithium disilicate-based core ceramic for three-unit esthetic fixed partial dentures: a 10-year prospective study.
2013
Purpose The aim of this prospective study was to evaluate the clinical efficacy and long-term survival rate of three-unit fixed partial dentures (FPDs) made from lithium disilicate-based core ceramic. Materials and methods Twenty-one three-unit FPDs were placed in 19 patients to replace single lost teeth in the esthetic area, following a study protocol that took clinical, esthetic, and radiologic aspects into consideration. Each case was reviewed at 1 week following placement, at 6 months, and then annually for 10 years. Statistical analysis was performed using Kaplan-Meier survival analysis. Results Out of the 19 patients, 14.3% presented reversible postoperative sensitivity. Recession was…
In vitro comparison of the retention capacity of new aesthetic brackets.
1999
Tensile bond strength and bond failure location were evaluated in vitro for two types of aesthetic brackets (non-silanated ceramic, polycarbonate) and one stainless steel bracket, using bovine teeth as the substrate and diacrylate resin as the adhesive. The results show that metallic bracket had the highest bond strength (13.21 N) followed by the new plastic bracket (12.01 N), which does not require the use of a primer. The non-silanated ceramic bracket produced the lowest bond strength (8.88 N). Bond failures occurred mainly between bracket and cement, although a small percentage occurred between the enamel-cement interface with the metal and plastic brackets and within the cement for the …
Comparative analysis of numerical and experimental data of orthodontic mini-implants
2011
The purpose of this study was to compare numerical simulation data derived from finite element analysis (FEA) to experimental data on mini-implant loading. Nine finite element (FE) models of mini-implants and surrounding bone were derived from corresponding experimental specimens. The animal bone in the experiment consisted of bovine rib. The experimental groups were based on implant type, length, diameter, and angle of insertion. One experimental specimen was randomly selected from each group and was digitized in a microCT scanner. The FE models consisted of bone pieces containing Aarhus mini-implants with dimensions 1.5 × 7 mm and 1.5 × 9 mm or LOMAS mini-implants (dimensions 1.5 × 7 mm, …
Influence of prefabricated post material on restored teeth: fracture strength and stress distribution.
2006
This work studied how prefabricated intraradicular post material affects the mechanical performance of restored teeth. The effect of using two different materials (glass fiber and stainless steel) with significantly different elastic moduli was studied.A combined theoretical and experimental method was used: first, an experimental fracture strength test was performed on 60 extracted human maxillary central incisors. The teeth were decoronated, treated endodontically and restored, 30 with glass fiber posts and 30 with stainless steel posts. The data were recorded and the results compared using an ANOVA test. Then, the finite element technique was used to develop a model of the restored tooth…
Comparative fracture behavior of monolithic and veneered zirconia posterior fixed dental prostheses
2017
The purpose of this study was to evaluate and to compare the fracture load and the fracture pattern of monolithic and veneered zirconia posterior fixed dental prostheses (FDPs). Twenty standardized steel dies were prepared to receive posterior 3-unit FDPs. Specimens were randomly divided into 2 groups (n=10): (1) Lava Zirconia, and (2) Lava Plus. All FDPs were cemented using glass ionomer cement and subjected to thermal and mechanical cycling at 5-55ºC with a 30-s dwell time for 120,000 masticatory cycles. All specimens were subjected to a three-point bending test until fracture. Data were statistically analyzed using Student's t test, paired t-test and Weibull statistics (α=0.05). No diffe…
Effect of Thermomechanical and Static Loading on the Load to Fracture of Metal‐Ceramic, Monolithic and Veneered Zirconia Posterior Fixed Partial Dent…
2018
PURPOSE To evaluate the influence of static (not preloaded) and thermomechanical loading on the load to fracture of metal-ceramic, monolithic and veneered zirconia computer-aided design/computer-aided manufacturing (CAD/CAM) posterior fixed partial dentures (FPDs). MATERIALS AND METHODS One hundred standardized specimens with 2 abutments screwed onto a platform were prepared from stainless steel to receive a posterior 3-unit FPD with an intermediate pontic. Specimens were randomly divided into 5 groups (n = 20): Metal-ceramic (control group), Lava Zirconia system, Vita In-Ceram YZ, IPS e.max ZirCAD, and Lava Plus. Half of the specimens of each group (n = 10) underwent no preloading, and the…