Search results for "design."
showing 10 items of 5715 documents
Crystalens HD Intraocular Lens Analysis Using an Adaptive Optics Visual Simulator
2013
PURPOSE To compare visual and optical quality of the Crystalens HD intraocular lens (IOL) with that of a monofocal IOL. METHODS The wavefront aberration patterns of the monocular Akreos Adapt AO IOL and the single-optic accommodating Crystalens HD IOL were measured in a model eye. The Crystalens IOL was measured in its nonaccommodative state and then, after flexing the haptic to produce 1.4 mm of movement, in its accommodative state. Using an adaptive optics system, subjects' aberrations were removed and replaced with those of pseudophakes viewing with either lens. Monocular distance visual acuity (DVA) at high (100%), medium (50%), and low (10%) contrast and contrast sensitivity (CS) were …
Is Activation of the Back Muscles Impaired by Creep or Muscle Fatigue?
2010
STUDY DESIGN: Intervention study on healthy human subjects. OBJECTIVE: To determine whether reflex activation of the back muscles is influenced by muscle fatigue or soft tissue creep in the spine. SUMMARY OF BACKGROUND DATA: Reflex contraction of the back muscles normally acts to limit spinal flexion, and hence protect the underlying spine from injury. However, repeated flexion allows bending moments on the spine to increase. Impaired reflexes as a result of fatigue or soft tissue creep may be contributing factors. METHODS: A total of 15 healthy volunteers (8 females/7 males aged 23-55 years) underwent 2 interventions, on separate days: (a) sitting flexed for 1 hour to induce creep and (b) …
Does Implementation Follow Design? A Case Study of a Workplace Health Promotion Program Using the 4-S Program Design and the PIPE Impact Metric Evalu…
2017
Objective: The aim of this study was to describe the content of a multiyear market-based workplace health promotion (WHP) program and to evaluate design and implementation processes in a real-world setting. Methods: Data was collected from the databases of the employer and the service provider. It was classified using the 4-S (Size, Scope, Scalability, and Sustainability) and PIPE Impact Metric (Penetration, Implementation) models. Data analysis utilized both qualitative and quantitative methods. Results: Program design covered well the evidence-informed best practices except for clear path toward sustainability, cooperation with occupational health care, and support from middle-management …
Reliability and Validity of a Further Tested Appreciative Management Scale
2020
Background and PurposeManagers need evidence-based methods to evaluate their management skills. To further test the appreciative management scale (AMS 1.0) to create a practical instrument to be used in evaluating appreciative management.MethodsFor further testing, a new survey was conducted among social and healthcare managers (n = 734) in Finland. Confirmatory factor analysis (CFA) was used to assess the scale validity and Cronbach's alpha coefficients the internal consistency.ResultsThe validated AMS 2.0 scale includes 24 items. The values measuring validity and reliability were good, with an Rool Mean Square Error of Approximation (RMSEA) of 0.072, Average Variance Extracted (AVE) value…
Is there a group effect? It depends on how you ask the question: Intraclass correlations for California Psychotherapy Alliance Scale–Group items.
2014
California Psychotherapy Alliance Scale-Group (CALPAS-G) data were collected from 1,138 group sessions attended by 248 group members in 16 counseling groups. Hierarchical linear modeling (HLM) was used to derive between-groups, between-member, and between-session variance components and intraclass correlation coefficients (ICCs) for the 12 CALPAS-G items. Using Ledermann and Kenny's (2012) descriptions of variable types, we examined differences in between-groups variance for the 6 CALPAS-G items classified as "Individual" items and the 6 CALPAS-G items classified as "Group" items. A Related-Samples Wilcoxon's Signed Ranked Test showed that the ICCs for the Group items were significantly lar…
Incidence of thromboembolic complications in patients with mechanical heart valves with a subtherapeutic international normalized ratio.
2008
Objective Subtherapeutic international normalized ratios are frequently encountered in clinical practice, and patients with mechanical heart valves with inadequate anticoagulation may be exposed to an increased risk of thromboembolic events. There are no data on thromboembolic event risk for these patients. Methods We assessed the current practice patterns in the management of patients with mechanical heart valves with subtherapeutic international normalized ratios and assessed the risk of thromboembolic complications in this setting. The charts of patients with mechanical heart valves followed up in two anticoagulation clinics were reviewed. Patients with a history of stable, therapeutic a…
A comparison of the cheater detection and the unrelated question models: a randomized response survey on physical and cognitive doping in recreationa…
2016
PURPOSE:This study assessed the prevalence of physical and cognitive doping in recreational triathletes with two different randomized response models, that is, the Cheater Detection Model (CDM) and the Unrelated Question Model (UQM). Since both models have been employed in assessing doping, the major objective of this study was to investigate whether the estimates of these two models converge. MATERIAL AND METHODS:An anonymous questionnaire was distributed to 2,967 athletes at two triathlon events (Frankfurt and Wiesbaden, Germany). Doping behavior was assessed either with the CDM (Frankfurt sample, one Wiesbaden subsample) or the UQM (one Wiesbaden subsample). A generalized likelihood-rati…
An alternative clinical routine for subjective refraction based on power vectors with trial frames.
2016
PURPOSE Subjective refraction determines the final point of refractive error assessment in most clinical environments and its foundations have remained unchanged for decades. The purpose of this paper is to compare the results obtained when monocular subjective refraction is assessed in trial frames by a new clinical procedure based on a pure power vector interpretation with conventional clinical refraction procedures. METHODS An alternative clinical routine is described that uses power vector interpretation with implementation in trial frames. Refractive error is determined in terms of: (i) the spherical equivalent (M component), and (ii) a pair of Jackson Crossed Cylinder lenses oriented …
Postoperative astigmatism and rotational stability after Artisan toric phakic intraocular lens implantation
2003
Abstract Purpose To evaluate deviations in the axis (intended versus achieved) and postoperative astigmatism after implantation of an Artisan toric phakic intraocular lens (IOL). Setting University Eye Hospital, Mainz, Germany. Methods This prospective study comprised 29 eyes with high ametropia and astigmatism. All eyes had uneventful implantation of a toric phakic IOL through a superior scleral tunnel incision at 12 o’clock. After a minimum of 6 months, the uncorrected visual acuity (UCVA), best correct visual acuity, refraction, and astigmatism were analyzed in all eyes. A multivariate analysis of postoperative astigmatism was performed. Results After a follow-up of at least 6 months, 95…
Long-term results of surgical treatment of high myopia with Worst-Fechner intraocular lenses
1995
Abstract This retrospective study evaluated the results in 90 eyes that had a minus-power anterior chamber intraocular lens implanted to correct high myopia. Preoperative myopia ranged from −7.00 to −24.00 D. Postoperative spherical equivalent was −0.50 D; 80.5% of eyes were within 1.00 D of emmetropia. Two years postoperatively, no cataract formation, retinal detachment, glaucoma, or significant endothelial damage had occurred. We conclude that minus-power lenses can rapidly, safely, and predictably correct high myopia in phakic patients.