OCT for Assessing Artificial Tears Effectiveness in Contact Lens Wearers
2011
PURPOSE: To apply a commercially available high-resolution spectral domain optical coherence tomographer (SOCT) to assess the change in tear volume after application of a new artificial tears formulation specifically developed for contact lens (CL) users. METHODS: Twenty OD from young healthy CL wearers (mean age, 24.7 ± 3.5 years) with refractive errors ranging from -0.75 to -2.50 D (mean, -1.56 ± 0.69 D) were examined. All subjects were fitted with Focus Dailies CL (Ciba Vision), and two drops of Blink Contacts (AMO), lubricating formulation specifically developed for CL wearers, were instilled after baseline measures. Tear meniscus volume (TMV) was measured immediately after and 1 min, 1…
Visual performance with simultaneous vision multifocal contact lenses.
2011
Purpose: The aim was to assess visual performance after PureVision high addition multifocal contact lens (PM) fitting through contrast sensitivity measured under different illumination levels for both distance and near. Methods: In a cross-over study, 20 presbyopic patients were randomly assigned to PM or spectacles. Near contrast sensitivity was measured with the Vistech VCTS 6500 system. Distance contrast sensitivity and distance visual acuity (VA) were measured with the Functional Vision Analyser under photopic (85 cd/m2) and mesopic (3.0 cd/m2) conditions, the latter also under two levels of induced glare: 1.0 lux and 28 lux. Near VA was measured by logMAR charts under approximately 8…
Biportal neuroendoscopic microsurgical approaches to the subarachnoid cisterns. A cadaver study.
1996
A preclinical cadaver study was performed to develop the technique of biportal neuroendoscopic dissection in the subarachnoid space of the basal cisterns and to test the feasibility, utility, and safety of this new technique. In 23 fresh post-mortem adult human cadavers and 2 formalin-fixed adult human head specimen a total of 33 biportal endomicrosurgical dissections into and within the basal cisterns were carried out. Following suction of cerebrospinal fluid from the subarachnoid space 0 degree-, 30 degrees-, and 70 degrees-lens-scopes (Aesculap AG, Tuttlingen, Germany) with outer diameters of 4.2 mm and trochars with outer diameters of 5 to 6.5 mm were introduced into the surgical field.…
Evaluation of the MGDRx eyebag treatment in young and older subjects with dry eye symptoms
2021
Summary Objectives This study aims to evaluate the relationship between application of the MGDRx thermal eyebag and dry eye signs and symptoms in young and older subjects and to compare the results between the two groups. Methods Thirty young, healthily volunteers between 18 and 31 years of age (23.95 ± 3.94 years) and thirty older subjects between 61 and 90 years of age (77.97 ± 8.11 years) participated in this study. Ocular surface parameters were assessed using the Oculus Keratograph 5 M, following the guidelines of the Tear Film and Ocular Surface Dry Eye Workshop II Diagnostic Methodology report. Only subjects with a positive score on at least one questionnaire and an initial Non-Invas…
Chimney and periscope grafts to facilitate endovascular treatment of aortic transection in a patient with aberrant right subclavian artery
2014
Purpose: To report the use of parallel grafts to extend the proximal landing zone for stentgraft repair of aortic transection involving an aberrant right subclavian artery (ARSA). Case Report: A 28-year-old patient was referred for treatment of traumatic aortic transection with contained rupture at the level of an ARSA. Immediate thoracic endovascular aortic repair (TEVAR) was planned because of hemodynamic instability. To achieve rapid sealing and maintain perfusion to both subclavian arteries, a chimney stent to the left subclavian artery (LSA) and a periscope stent-graft to the ARSA were deployed successfully. After surgical repair of all fractures, the patient was discharged 1 month aft…
Treating Cockroach Phobia With Augmented Reality
2009
In vivo exposure is the recommended treatment of choice for specific phobias; however, it demonstrates a high attrition rate and is not effective in all instances. The use of virtual reality (VR) has improved the acceptance of exposure treatments to some individuals. Augmented reality (AR) is a variation of VR wherein the user sees the real world augmented by virtual elements. The present study tests an AR system in the short (posttreatment) and long term (3, 6, and 12 months) for the treatment of cockroach phobia using a multiple baseline design across individuals (with 6 participants). The AR exposure therapy was applied using the "one-session treatment" guidelines developed by Öst, Salko…
Capsular bag shrinkage after implantation of a capsular bending or capsular tension ring.
2005
To evaluate the influence of a capsular bending ring (CBR) or tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, and Department of Medical Biometry, Epidemiology and Informatics, University of Mainz, Mainz, Germany.In 92 eyes of 92 patients, a capsular measuring ring (CMR) was implanted after phacoemulsification to measure capsular bag size in vivo. Patients were randomized into 3 groups: The first received a CMR and CBR, the second received a CMR and CTR, and the third received a CMR alone. Measurements were performed preoperatively, intraoperatively, during the first 3 postoperative days, and after 1 and 3 months. Preoperative biometri…
Fixed Implant-Supported Full-Arch Prosthesis in Epidermolysis Bullosa With Severe Symptoms
2016
Contrast sensitivity after LASIK flap creation with a femtosecond laser and a mechanical microkeratome
2007
ABSTRACT PURPOSE: To compare the effects on contrast sensitivity of the IntraLase femtosecond laser for flap creation (IntraLASIK) and standard LASIK for myopia. METHODS: Two hundred eyes of 100 consecutive patients underwent LASIK treatment using the VISX S2 laser system. The femtosecond laser (15 kHz IntraLase) was used for flap creation in 100 eyes (50 patients) and a mechanical microkeratome (Carriazo-Barraquer) was used in 100 eyes (50 patients). Best spectacle-corrected contrast sensitivity was measured before and 6 months postoperatively in the IntraLASIK and mechanical LASIK groups. The IntraLASIK and mechanical LASIKinduced changes in contrast sensitivity were compared under photop…
Contrast sensitivity after implantation of toric iris-claw lenses in phakic eyes.
2004
Abstract Purpose: To evaluate the change in contrast sensitivity after implantation of the Verisyse toric phakic intraocular lens (IOL) (AMO) for the correction of myopia with astigmatism. Setting: Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods: Eighteen eyes had implantation of an iris-supported toric phakic IOL to correct myopia with astigmatism. The mean preoperative spherical equivalent was −12.65 diopters ± 3.6 (SD). The contrast sensitivity with best spectacle correction was determined before surgery and 3 months after surgery using the CSV-1000 HGT instrument (Vector Vision Inc.). Results: Three months after IOL implantation, the mean contrast sen…