X-ray spectroscopy and dosimetry with a portable CdTe device.
2007
Abstract X-ray spectra and dosimetry information are very important for quality assurance (QA) and quality control (QC) in medical diagnostic X-ray systems. An accurate knowledge of the diagnostic X-ray spectra would improve the patient dose optimization, without compromising image information. In this work, we performed direct diagnostic X-ray spectra measurements with a portable device, based on a CdTe solid-state detector. The portable device is able to directly measure X-ray spectra at high photon fluence rates, as typical of clinical radiography. We investigated on the spectral performances of the system in the mammographic energy range (up to ∼40 keV). Good system response to monoener…
High Energy, High Resolution X-Ray Spectroscopy: Microcalorimeters For Nuclear Line Astrophysics
2005
We introduce focusing optics and microcalorimeter spectroscopy to nuclear line emission astrophysics with a balloon payload concept called, B‐MINE. It is designed to probe the deepest regions of a supernova explosion by detecting 44Ti emission at 68 keV with spatial and spectral resolutions that are sufficient to determine the velocity distribution of the 44Ti emitting region. B‐MINE has a thin plastic foil telescope multilayered to maximize the reflectivity in a 20 keV band centered at 68 keV and a microcalorimeter array optimized for the same energy band. This combination provides a reduced background, an energy resolution of 50 eV and a 3σ sensitivity in 106 s of 6 × 10−8 ph cm−2 s−1 at …
Characterization of Al-Schottky CdTe detectors
2011
In the last decades, great efforts are being devoted to the development of CdTe detectors for high resolution X-ray and gamma ray spectroscopy. Recently, new rectifying contacts based on aluminum (Al) are very appealing in the development of CdTe detectors with low leakage currents and anode pixellization. In this work, we report on preliminary results of electrical and spectroscopic investigations on Schottky CdTe diode detectors (4.1 × 4.1 × 0.75 and 4.1 × 4.1 × 2 mm3) with Au/Ti/Al/CdTe/Pt electrode configuration. The detectors are characterized by very low leakage currents even at room temperature (26 pA at 25 °C under a bias voltage of −100 V for the 2 mm thick detector). Polarization …
Confirming band assignments in $^{167}$ytterbium with gamma-gamma-electron triple-coincidence spectroscopy
2019
International audience; Multipolarity measurements are presented for transitions in the deformed odd-mass nucleus$^{167}$ Yb in support of tentative spin assignments and level interpretations based upon the cranked-Nilsson model. Internal-conversion coefficients were measured with the SAGE (Silicon And GErmanium) spectrometer confirming several E2 transition assignments. The array of high-purity germanium detectors enabled the recording of high-multiplicity events from which $\gamma\gamma\gamma$ and $\gamma\gamma e^{-}$ data sets were extracted and the technique of high-fold $\gamma$ -ray gating was demonstrated to cleanly isolate transitions of interest.
ERRATUM: "Search for High-Energy Muon Neutrinos from the "Naked-Eye" GRB 080319B with the Icecube Neutrino Telescope" (2009, ApJ, 701, 1721)
2009
We have noticed some mistakes in formulae (A2) and (A5) in the appendix of our paper. The errors are not present in the code used in the analysis and hence none of the plots or results is affected. The correct formulae are below.
Thin plastic shell x-ray optics: an update
2003
We present new results from a program to develop large area X-ray telescopes that are made from thin plastic shells. We use multi-shell cylindrical lenses in a point-to-point configuration to form full aperture images of the small focal spot in a an X-ray tube on a microchannel plate detector. The image data are analyzed to yield radial profiles and encircled energy curves. The derived parameters can be extrapolated to the case of a telescope that is a conical approximation to Wolter 1 optics. The plastic shells can be coated with suitable mono- or multilayers that allow for a wideband coverage of X-ray energies. Our current program is focused on the development of a large area, hard X-ray …
Simbol-X Mirror Module Thermal Shields: I-Design and X-Ray Transmission
2009
The Simbol‐X mission is designed to fly in formation flight configuration. As a consequence, the telescope has both ends open to space, and thermal shielding at telescope entrance and exit is required to maintain temperature uniformity throughout the mirrors. Both mesh and meshless solutions are presently under study for the shields. We discuss the design and the X‐ray transmission.
Design and implementation of electronics and data acquisition system for Ultra-Fast Flash Observatory
2013
The Ultra-Fast Flash Observatory (UFFO) Pathfinder for Gamma-Ray Bursts (GRBs) consists of two telescopes. The UFFO Burst Alert & Trigger Telescope (UBAT) handles the detection and localization of GRBs, and the Slewing Mirror Telescope (SMT) conducts the measurement of the UV/optical afterglow. UBAT is equipped with an X-ray detector, analog and digital signal readout electronics that detects X-rays from GRBs and determines the location. SMT is equipped with a stepping motor and the associated electronics to rotate the slewing mirror targeting the GRBs identified by UBAT. First the slewing mirror points to a GRB, then SMT obtains the optical image of the GRB using the intensified CCD an…
Status of the EPIC thin and medium filters on-board XMM-Newton after more than 10 years of operation I: laboratory measurements on back-up filters
2013
After more than ten years of operation of the EPIC camera on board the X-ray observatory XMM-Newton, we have reviewed the status of its Thin and Medium filters by performing both laboratory measurements on back-up filters, and analysis of data collected in-flight. We have selected a set of Thin and Medium back-up filters among those still available in the EPIC consortium, and have started a program to investigate their status by different laboratory measurements including: UV/VIS transmission, X-ray transmission, RAMAN IR spectroscopy, X-Ray Photoelectron Spectroscopy, and Atomic Force Microscopy. We report the results of the measurements conducted up to now, and point out some lessons lear…
Vibration Detector Based on GMR Sensors
2009
Up to now, vibrations have mostly been sensed by measuring displacement, velocity, and acceleration. The most common types of vibration sensors are piezoelectric, capacitive, null-balance, strain gage, optoelectronic, resonance beam, and piezoresistive. We present a low-cost and low-power vibration detector based on the measurement of magnetic field variations induced in a recent SS501 giant magnetoresistance (GMR) magnetic sensor, for which has never been applied. Vibrations on small ferromagnetic pieces disturb the Earth's magnetic field. These weak perturbations can be detected and measured over the assumed constant Earth's magnetic field, which is uniform over a wide area. A novel array…