Search results for "detector"

showing 10 items of 3491 documents

A compact system for high precision time measurements ( < 14 ps RMS) and integrated data acquisition for a large number of channels

2011

A high precision ( < 14 ps RMS time resolution) and high channel density ( ~ 256 channels) Time to Digital Converter (TDC) module (realized in FPGAs) with integrated DAQ is presented. The data is transported over up to 8 Gigabit-Ethernet or optical links with up to 3 Gb/s. Slow-Control information is transported over the same links. It can be attached directly to the detector, which allows the elimination of long cables and crate systems. The full 256 channel TDCs are expected to use approximately 30 W electrical power. The module size is 20 cm by 23 cm. Power is provided by a galvanically isolated 48 V low noise power supply. AddOn-boards adapt to the special needs of the detector to be re…

Physicsbusiness.industryDetectorElectrical engineeringNoise (electronics)Power (physics)Time-to-digital converterData acquisitionbusinessField-programmable gate arrayInstrumentationGalvanic isolationMathematical PhysicsCommunication channelJournal of Instrumentation
researchProduct

Rule-guided identification of cosmic-ray patterns in PLASTEX

1992

Some techniques devised in the computer science fields of pattern recognition and expert systems are being applied to the interpretation of EAS responses in the PLASTEX experiment. An attempt is made to codity in a set of rules the expertise of trained researchers who are able to recognize and classify different hit patterns even in the presence of noisy background, and in spite of imperfections in the detector response. The patterns expected to be useful include, but are not limited to, track patterns. The software described here, as a progress report, automatically finds patterns corresponding to isolated tracks, and patterns composed of tracks that connect with each other in a layer of d…

Physicsbusiness.industryDetectorProbabilistic logiccomputer.software_genreExpert systemSet (abstract data type)Identification (information)SoftwareOpticsPattern recognition (psychology)Extensive air showersCosmic-raysData pre-processingbusinessComputation techniquesPACS 94.40.MyAlgorithmcomputer
researchProduct

High-rate x-ray spectroscopy in mammography with a CdTe detector: A digital pulse processing approach

2010

Purpose:Direct measurement of mammographic x-ray spectra under clinical conditions is a difficult task due to the high fluence rate of the x-ray beams as well as the limits in the development of high resolution detection systems in a high counting rate environment. In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate x-ray spectroscopy in mammography. Methods: The DPP system performs a digital pile-up inspection and a digital pulse height analysis of the detector signals, digitized through a 14-bit, 100 MHz digitizer, for x-ray spectroscopy even at high photon counting rates. We investigated on the respon…

Physicsbusiness.industryDetectorX-ray detectorGeneral MedicinePhoton countingFull width at half maximumOpticsQuality (physics)Ionization chamberSpectroscopybusinessNuclear medicineHalf-value layerMedical Physics
researchProduct

Development of a TES based Cryo-Anticoincidence for a large array of microcalorimeters

2009

The employment of large arrays of microcalorimeters in space missions (IXO, EDGE/XENIA)[1][2][3], requires the presence of an anticoincidence detector to remove the background due to the particles, with a rejection efficiency at least equal to Suzaku (98%) [1]. A new concept of anticoincidence is under development to match the very tight thermal requirements and to simplify the design of the electronic chain. The idea is to produce a Cryo-AntiCoincidence (Cryo-AC) based on a silicon absorber and read by a TES (Transition-Edge Sensor). This configuration would ensure very good performances in terms of efficiency, time response and signal to noise ratio. We present the results of estimations,…

Physicsbusiness.industryLarge arrayBolometerDetectorParticle detectorSpace explorationlaw.inventionPhysics and Astronomy (all)OpticsSignal-to-noise ratioMicrocalorimeterlawThermalDevelopment (differential geometry)Particle detectorX-ray detectors microcalorimeters backgroundAnticoincidencebusinessAnticoincidence; Microcalorimeter; Particle detector; TES; X ray detector; Physics and Astronomy (all)TESX ray detectorAIP Conference Proceedings
researchProduct

Non-destructive single-pass low-noise detection of ions in a beamline.

2015

We have conceived, built, and operated a device for the non-destructive single-pass detection of charged particles in a beamline. The detector is based on the non-resonant pick-up and subsequent low-noise amplification of the image charges induced in a cylindrical electrode surrounding the particles' beam path. The first stage of the amplification electronics is designed to be operated from room temperature down to liquid helium temperature. The device represents a non-destructive charge counter as well as a sensitive timing circuit. We present the concept and design details of the device. We have characterized its performance and show measurements with low-energy highly charged ions (such …

Physicsbusiness.industryLiquid heliumDetectorNanotechnologyPenning trapNoise (electronics)Charged particleIonlaw.inventionOpticsBeamlinelawbusinessInstrumentationBeam (structure)The Review of scientific instruments
researchProduct

Design of an integrated low-noise, low-power charge sensitive preamplifier for γ and particle spectroscopy with solid state detectors

2014

The design of an integrated charge-sensitive preamplifier suitable for γ-ray spectroscopy is presented. It is fully integrated, except for the feedback resistor, and can drive directly a 50Ω cable with its low impedance output stage. It is designed in AMS 0.35µm technology and its small dimensions and low power consumption (10 mW) are optimized for multi-channel applications. It works both with germanium and silicon detectors for a large range of values of electrode and feedback capacitances. Its wide bandwidth ensures a risetime of 10 ns or less in most configurations. This characteristic makes the preamplifier suitable not only for high resolution spectroscopy but also for pulse-shape ana…

Physicsbusiness.industryPreamplifierBandwidth (signal processing)DetectorTransistorElectrical engineeringJFETCapacitancelaw.inventionlawElectronic engineeringResistorbusinessSpectroscopy2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)
researchProduct

Background Rejection of Charged Particles in the Simbol-X Telescope: Preliminary Study of Protons Scattering

2009

X-ray telescopes equipped with focusing optics in high eccentric orbit, as e.g. Newton-XMM and Chandra, showed a degradation of the detector performance and an important increase of the noise due to soft protons with energy between a few tens of keV and a few MeV, that are focused on the detector through the mirror module. It should be noted that the focusing of the protons by Wolter optics was an unexpected phenomenon. In Simbol-X a magnetic diverter will be implemented to deflect protons, in order to reduce the flux of charged particles impinging upon the focal plane. Obviously the design of the diverter should take into consideration the protons distribution at the exit of the mirror mod…

Physicsbusiness.industryScatteringAstrophysics::High Energy Astrophysical PhenomenaDetectorX-ray opticsCharged particleParticle detectorlaw.inventionTelescopeSettore FIS/05 - Astronomia E AstrofisicaOpticsCardinal pointlawX- and gamma-ray telescopes and instrumentation X-ray beams and x-ray optics Lenses prisms and mirrorsbusinessNoise (radio)AIP Conference Proceedings
researchProduct

The Performance of Belle II Data Acquisition System in the First Physics Run

2019

The Belle II experiment is a new generation B-factory experiment at KEK in Japan aiming at the search for New Physics in a huge sample of B-meson dacays. The commissioning of the SuperKEKB accelerator was started in 2017 (Phase 1), and then a pilot run with outer detectors was performed in 2018 (Phase 2). From March this year, an operation with the full detector has been started for the physics data taking (Phase 3). The Belle II data acquisiton system (DAQ) is now fully working in the Phase 3 run. The system consists of the trigger timing distribution system, the common readout modules (COPPER) with the unified optical data link to the detector front end, the readout PCs and the network sw…

Physicsbusiness.product_categoryPhysics::Instrumentation and Detectors010308 nuclear & particles physicsbusiness.industrymedia_common.quotation_subjectDetector01 natural sciencesSample (graphics)Front and back endsData acquisitionDebugging0103 physical sciencesComputer data storageNetwork switch010306 general physicsbusinessComputer hardwareData reductionmedia_common2019 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)
researchProduct

Forward-central two-particle correlations in p–Pb collisions at sNN=5.02 TeV

2016

Two-particle angular correlations between trigger particles in the forward pseudorapidity range (2.5 < |η| < 4.0) and associated particles in the cen

Physicscongenital hereditary and neonatal diseases and abnormalitiesNuclear and High Energy PhysicsParticle physicsTime projection chamber010308 nuclear & particles physicsAtlas detector01 natural sciencesCharged particleNuclear physicsMuon spectrometerPseudorapidity0103 physical sciencesTransverse momentumRapidityMultiplicity (chemistry)010306 general physicsPhysics Letters B
researchProduct

Searches for neutrinoless resonant double electron captures at LNGS

2012

Several experiments were performed during last years at underground (3600 m w.e.) Laboratori Nazionali del Gran Sasso (LNGS) of the INFN (Italy) to search for resonant 2$\varepsilon0\nu$ captures in 96Ru, 106Cd, 136Ce, 156Dy, 158Dy, 180W, 184Os, 190Pt with the help of HP Ge semiconductor detectors, and ZnWO4 and 106CdWO4 crystal scintillators. No evidence for r-2$\varepsilon0\nu$ decays was found, and only T_{1/2} limits were established in the range of 10^{14}-10^{21} yr.

Physicsdouble beta decay; low background physics;HistoryRange (particle radiation)low background physicsdouble beta decayFOS: Physical sciencesElectronScintillatorComputer Science ApplicationsEducationSemiconductor detectorSettore FIS/04 - Fisica Nucleare e SubnucleareCrystalNuclear physicsNuclear Experiment (nucl-ex)Nuclear Experiment
researchProduct