Search results for "detector"
showing 10 items of 3491 documents
First experiment with the NUSTAR/FAIR Decay Total Absorption γ-Ray Spectrometer (DTAS) at the IGISOL IV facility
2015
V. Guadilla et al. ; 4 págs.; 4 figs.; 1 tab.
The HITRAN2016 molecular spectroscopic database
2017
This paper describes the contents of the 2016 edition of the HITRAN molecular spectroscopic compilation. The new edition replaces the previous HITRAN edition of 2012 and its updates during the intervening years. The HITRAN molecular absorption compilation is composed of five major components: the traditional line-by-line spectroscopic parameters required for high-resolution radiative-transfer codes, infrared absorption cross-sections for molecules not yet amenable to representation in a line-by-line form, collision-induced absorption data, aerosol indices of refraction, and general tables such as partition sums that apply globally to the data. The new HITRAN is greatly extended in terms of …
Ex vivo measurement reliability using two different cbct scanners for orthodontic purposes
2012
Background There are many cone beam computed tomography (CBCT) scanners available on the market: detector technology, algorithm precision, and scanner settings influence image quality. The aim of this study was to compare the accuracy of linear measurements made on images of the same sample obtained using two different CBCT scanners. Methods Twenty-eight linear measurements between orthodontic anatomical landmarks that were marked with gutta-percha points on a fresh sacrificed lamb head were taken three times. The head was scanned with two CBCT scanners using different scanning parameters. Digital Imaging and Communications in Medicine (DICOM) images were reconstructed and the same measurem…
Thermoelastic stress analysis by means of an infrared scanner and a two-dimensional fast Fourier transform-based lock-in technique
2008
An infrared thermographic experimental set-up has been proposed and evaluated towards the capability to measure thermoelastic-effect-induced temperature changes. A standard infrared thermocamera with a nominal noise-equivalent temperature difference (NETD) resolution of 0.12 K has been employed to measure the temperature from unidirectional glass-reinforced plastic tensile coupons under cyclic sinusoidal loads. The raster scanning mode of the camera single detector produces a time delay in acquiring the signal from two succeeding pixels on the same row, and from consecutive scanned rows. By exploiting the acquired dwell times, it was possible to produce a periodic pattern on the thermal ma…
A high-resolution PET demonstrator using a silicon "magnifying glass".
2021
Abstract To assist ongoing investigations of the limits of the tradeoff between spatial resolution and noise in PET imaging, several PET instruments based on silicon-pad detectors have been developed. The latest is a segment of a dual-ring device to demonstrate that excellent reconstructed image resolution can be achieved with a scanner that uses highresolution detectors placed close to the object of interest or surrounding a small field-of-view in combination with detectors having modest resolution at larger radius. The outer ring of our demonstrator comprises conventional BGO block detectors scavenged from a clinical PET scanner and located at a 500 mm radius around a 50 mm diameter field…
XENON100 dark matter results from a combination of 477 live days
2016
We report on WIMP search results of the XENON100 experiment, combining three runs summing up to 477 live days from January 2010 to January 2014. Data from the first two runs were already published. A blind analysis was applied to the last run recorded between April 2013 and January 2014 prior to combining the results. The ultra-low electromagnetic background of the experiment, ~$5 \times 10^{-3}$ events/(keV$_{\mathrm{ee}}\times$kg$\times$day) before electronic recoil rejection, together with the increased exposure of 48 kg $\times$ yr improves the sensitivity. A profile likelihood analysis using an energy range of (6.6 - 43.3) keV$_{\mathrm{nr}}$ sets a limit on the elastic, spin-independe…
Compressive imaging in scattering media.
2015
One challenge that has long held the attention of scientists is that of clearly seeing objects hidden by turbid media, as smoke, fog or biological tissue, which has major implications in fields such as remote sensing or early diagnosis of diseases. Here, we combine structured incoherent illumination and bucket detection for imaging an absorbing object completely embedded in a scattering medium. A sequence of low-intensity microstructured light patterns is launched onto the object, whose image is accurately reconstructed through the light fluctuations measured by a single-pixel detector. Our technique is noninvasive, does not require coherent sources, raster scanning nor time-gated detection…
A gray-level 2D feature detector using circular statistics
1997
Abstract This paper presents a new method for corner and circular feature detection in gray-level images. It is based on the application of standard statistical techniques to the distribution of gradient orientations in a circular neighborhood of the prospective feature point. An evaluation using standard procedures and a comparison with other approaches is presented. Results show the robustness of this method as compared to the other corner detectors analyzed. The main novelties are the possibility of detecting points that are centers of circular symmetries, and discriminating between junctions, which are classified into corners (two-edge junctions) and multiple edge junctions.
Gravitational-wave parameter inference using Deep Learning
2021
We explore machine learning methods to detect gravitational waves (GW) from binary black hole (BBH) mergers using deep learning (DL) algorithms. The DL networks are trained with gravitational waveforms obtained from BBH mergers with component masses randomly sampled in the range from 5 to 100 solar masses and luminosity distances from 100 Mpc to, at least, 2000 Mpc. The GW signal waveforms are injected in public data from the O2 run of the Advanced LIGO and Advanced Virgo detectors, in time windows that do not coincide with those of known detected signals, and the data from each detector in the Advanced LIGO and Advanced Virgo network is combined into a unique RGB image. We show that a clas…
Energy and time resolution for a LYSO matrix prototype of the Mu2e experiment
2016
We have measured the performances of a LYSO crystal matrix prototype tested with electron and photon beams in the energy range 60$-$450 MeV. This study has been carried out to determine the achievable energy and time resolutions for the calorimeter of the Mu2e experiment.